Lithium and VRLA lead-acid
Batteries and cabinets
LiFePO4 lithium cabinets with hot-swap modules, steel battery cabinets and OZ Power AGM VRLA batteries. L6 with 40, 50 or 100 Ah modules; BB1–BB8, BBJ and BBJ2 cabinets; OZ Power 12 V blocks from 9 to 200 Ah.



Models
One model, one page
Every rating has its own page: that model's technical data, ordering codes, batteries and the questions people ask.
Comparison
Batteries and cabinets: how do the ranges compare?
| Range | Ratings | Voltage | Description | Batteries |
|---|---|---|---|---|
| L6 Lithium | 40 · 50 · 100 Ah | 240 / ±240 / 480 V DC | Modular lithium battery system, 40 · 50 · 100 Ah | Lithium |
| Battery cabinets | 9–100 Ah | 12 V VRLA AGM · ±240 V DC | Battery cabinets and VRLA batteries for AEC UPS | VRLA |
| OZ Power VRLA | 9–200 Ah | 12 V | OZ Power AGM batteries 12 V | VRLA |
Questions
Questions people ask
Lithium or VRLA: which battery should I choose for my UPS?
The L6 uses lithium iron phosphate modules rated for 5,000 cycles at 50% depth of discharge, hot-swappable and monitored by a three-layer BMS, for AEC IST7 and IST6 UPS from 6 to 1200 kVA. OZ Power VRLA AGM batteries are sealed and maintenance-free, with a design life of 6–8 years (9–24 Ah) or 12 years (40–200 Ah), and go into AEC battery cabinets.
How do lithium and VRLA cabinets compare in size?
An L6 cabinet measures 600 × 850 × 2000 mm and stores up to 41, 58 or 69 kWh depending on the module. VRLA cabinets range from the BB5 at 460 × 800 × 1400 mm to the BB8 at 1400 × 800 × 1900 mm, which holds up to 64 batteries of 80 or 100 Ah in two strings.
How does maintenance differ between lithium and VRLA?
VRLA cabinets need monthly visual checks, battery voltages every 6 months, terminal torque every 12 months and a capacity test or replacement every 3–5 years. L6 maintenance is done online, module by module: a faulty module leaves the system on its own and is replaced in about 5 minutes.
Which OZ Power battery goes in which AEC cabinet?
The 9 Ah block goes in the UPS and in BB1–BB5 and BBJ cabinets, 24 and 40 Ah in the BB5, 60 Ah in BB6 and BB7, and 80 and 100 Ah in BB7 and BB8. The 200 Ah block is for large systems, on request.
Who sizes the battery for my project?
AEC sizes the battery for every project: send the loads and the backup time required to sales@aecups.com or +39 02 9415 8991. AEC engineers choose the module or battery type, the quantity, the cabinets and the reserve.
Guides
Guides: Batteries and cabinets
Talk to an AEC engineer
Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.