ETHERNO · 208V three-phase UPS

ETH30-3X50A-LI ETHERNO 30 kVA, 208V three-phase UPS

Lithium30 kVAOnline double conversion

The AEC ETHERNO ETH30-3X50A-LI is a 30 kVA / 30 kW online double-conversion UPS for 208 V three-phase loads, with three 50 Ah lithium modules: 14 minutes at full load, 27 at half load. Kept at 80 % of its rating, it carries loads up to 24 kW.

30 kVA / 30 kWRating
12.6 × 39.1 × 49.2 inW × D × H
485 lbWeight
Lithium, internalBattery

Series picture.

AEC ETH30-3X50A-LI, rendered from its 3D modelDrag to turn

In 3D

Look around the ETH30-3X50A-LI

Runtime

ETHERNO 30 kVA · 3 lithium modules at your load.

The same chart as the ETHERNO page: this model in bold, the other set-ups faded behind it to compare. 2026 catalog, new batteries.

50 %
102050100200500100010%25%50%75%100%ETH10-2X50A-LIETH10-3X50A-LIETH20-3X50A-LIETH10-1X50A-LI, ETH20-2X50A-LI, ETH30-3X50A-LIminutes (log scale)
ETHERNO 10 kVA · 1 lithium module and 2 more, same minutesETHERNO 10 kVA · 2 lithium modulesETHERNO 10 kVA · 3 lithium modulesETHERNO 20 kVA · 3 lithium modules
Table: this model at 25, 50, 75 and 100 % load
Model25% load50% load75% load100% load
ETHERNO 30 kVA · 3 lithium modulesETH30-3X50A-LI55 min27 min17.5 min14 min

Every ETHERNO set-up in one table

From the 2026 catalog

What is the ETH30-3X50A-LI?

The code ETH30-3X50A-LI orders these catalog items, shipped in 4 cartons:

  • 1 × ETH30: 30 kVA tower, without batteries, 12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm), 240.2 lb (109 kg)
  • 3 × ETH-50-LI: 50 Ah LiFePO4 lithium module, 81.6 lb (37 kg) each
  • Output: 30,000 VA / 30,000 W (unity power factor, kVA = kW).
  • Battery: 3 × hot-swappable LiFePO4 50 Ah lithium modules; 15-year module life; recharge < 2 h.

The lines every ETHERNO shares, from technology to warranty, are in the ETHERNO key facts and in the datasheet below.

Size and floor

How big it is

12.6" W × 39.1" D × 49.2" H (320 × 993 × 1,250 mm); 485 lb (220 kg) net. It ships in 4 cartons, 557.1 lb (252.7 kg) gross in all.

3.4 ft²footprint (0.32 m²)
142 lb/ft²floor load of the cabinet alone
Towerform factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

5′9″ FrontSide 12.6″39.1″49.2″

Datasheet

ETH30-3X50A-LI datasheet.

The ETH30-3X50A-LI in the AEC 2026 catalog, figure by figure. Compare it with every ETHERNO model.

ETH30-3X50A-LI datasheet
ParameterETH30-3X50A-LI
Power
Rated power (kVA)30
Active power (kW)30
Output power factor1.0
Electrical
Input / output208 V three-phase, 4-wire (3P+N)
TopologyOnline Double Conversion
Efficiency, up to94%
Battery DC bus240 V DC
Battery and runtime
Battery typeLithium LiFePO4
Battery configurationInternal
Runtime at 50 % load27 min
Runtime at 100 % load14 min
Mechanical
Form factorTower
Dimensions W × D × H12.6 × 39.1 × 49.2 in (320 × 993 × 1,250 mm)
Net weight485 lb (220 kg)
Footprint3.4 ft² (0.32 m²)
Shipping
Cartons4
Shipping weight557.1 lb
Common to every ETHERNO
Technology3-level IGBT; cold start, self-cleaning and smart functions
Display4.3-inch color touchscreen
CommsModbus and dry contacts, standard
Battery, ETH30-3X50A-LI3 × hot-swappable LiFePO4 50 Ah lithium modules; 15-year module life; recharge < 2 h
Network cardSNMP-L (SNMP)
Warranty5 years
CertificationUL 1778 listed, UL file E543003 (AEC UPS USA LLC)
Quality systemISO 9001:2015, the group's quality system (SGS)

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

ETH30-3X50A-LI: what people ask

How long does the ETH30-3X50A-LI run on battery?

14 min at 100 % load (30 kW), 27 min at 50 % load (15 kW), 2 h 13 min at 10 % load (3.0 kW), from the catalog runtime table at the start of battery life. Runtime falls faster than the load rises, so the ETH30-3X50A-LI chart above gives the minutes at any load in between.

What is the output current of the ETH30-3X50A-LI?

83.3 A per phase at full load: 30 kVA ÷ (√3 × 208 V). Size the input breaker and the cables of the ETH30-3X50A-LI from its installation manual and the local electrical code, not from this figure alone.

How much heat does the ETH30-3X50A-LI give off?

About 2.0 kW, 6,770 BTU/h, at full load, where it is 93.8% efficient. Plan the room's cooling for a little more than that: the ETH30-3X50A-LI is less efficient at part load and while its battery recharges.

Will the ETH30-3X50A-LI fit through a standard door?

Yes: 12.6 in (320 mm) across its narrow side and 49.2 in (1,250 mm) high, it passes a standard 36 × 80-inch door upright. On the way in, check corridors, elevators and the floor load of the ETH30-3X50A-LI (size section above).

The method, for any UPS: runtime explained · amps from kVA · heat output in BTU/h

ETHERNO

Other ETHERNO models

The ETHERNO series, with pictures

By power, the ETH30-3X50A-LI is the largest in the ETHERNO series, which runs from 10 to 30 kVA. One size down are the ETH20, ETH20-2X50A-LI and ETH20-3X50A-LI, all 10 kVA less. The same 30 kVA also comes as ETH30 (lithium modules inside, ordered separately, 245 lb lighter); the ETH30-3X50A-LI has internal batteries.

Every ETHERNO model side by side (9)
ETHERNO models side by side
ModelPowerPower against this modelNet weightWeight against this modelRuntime at 50 % loadBattery configuration
ETH1010 kVA20 kVA less216 lb269 lb lighter—Lithium modules inside, ordered separately
ETH10-1X50A-LI10 kVA20 kVA less298 lb187 lb lighter27 min at 50 % loadInternal
ETH10-2X50A-LI10 kVA20 kVA less379 lb106 lb lighter55 min at 50 % loadInternal
ETH10-3X50A-LI10 kVA20 kVA less461 lb24 lb lighter82 min at 50 % loadInternal
ETH2020 kVA10 kVA less227 lb258 lb lighter—Lithium modules inside, ordered separately
ETH20-2X50A-LI20 kVA10 kVA less390 lb95 lb lighter27 min at 50 % loadInternal
ETH20-3X50A-LI20 kVA10 kVA less472 lb13 lb lighter41 min at 50 % loadInternal
ETH3030 kVAthe same power240 lb245 lb lighter—Lithium modules inside, ordered separately
ETH30-3X50A-LI30 kVAthis page485 lbthis page27 min at 50 % loadInternal

The ETH30-3X50A-LI for your project

Send the load, the voltage and the minutes you need from the ETH30-3X50A-LI. We reply with the configuration, the batteries and the lead time.