CIRRO-IB · 480 V three-phase UPS
CIRIB150 CIRRO-IB 150 kVA frame, 30–150 kVA fitted
The AEC CIRRO-IB CIRIB150 is a 150 kVA modular UPS frame for 480 V three-phase loads with five slots for 30 kVA hot-swappable power modules. The 2026 catalog lists it with 1, 2, 3, 4 or 5 modules fitted, 30–150 kVA in all; each code is a row below.
4-wire · 3P+N480 V 4-wire, wye: three phases, neutral and ground (277/480 V)
Series picture.
5 ordering codes
Which CIRIB150 do you need?
One 150 kVA frame, a row per number of modules fitted. Only what changes from one code to the next is here; what they share is under the table.
| Ordering code | Power | Free slots | With one module spare (N+1) | Net weight | Floor load | Current per phase at 480 V | Cartons |
|---|---|---|---|---|---|---|---|
| CIRIB150-1X301 × 30 kVA power module3DAsk | 30 kVA / 30 kW | 4 of 5 | no spare with one module | 2,191.8 lb (994.2 kg) | 340 lb/ft² | 36.1 A | 26 |
| CIRIB150-2X302 × 30 kVA power modules3DAsk | 60 kVA / 60 kW | 3 of 5 | 30 kVA | 2,243.8 lb (1,017.8 kg) | 348 lb/ft² | 72.2 A | 27 |
| CIRIB150-3X303 × 30 kVA power modules3DAsk | 90 kVA / 90 kW | 2 of 5 | 60 kVA | 2,295.8 lb (1,041.4 kg) | 356 lb/ft² | 108 A | 28 |
| CIRIB150-4X304 × 30 kVA power modules3DAsk | 120 kVA / 120 kW | 1 of 5 | 90 kVA | 2,347.8 lb (1,065 kg) | 365 lb/ft² | 144 A | 29 |
| CIRIB150-5X305 × 30 kVA power modules3DAsk | 150 kVA / 150 kW | none of 5 | 120 kVA | 2,399.8 lb (1,088.6 kg) | 373 lb/ft² | 180 A | 30 |
This model
What sets the CIRIB150 apart
The CIRRO-IB is one 150 kVA frame for 480 V three-phase that carries its batteries inside: five slots for 30 kVA power modules and trays for 240 blocks of 12 V 9 Ah, all in one 23.6 × 39.3 × 78.7 in cabinet. The catalog lists it with one to five modules, 30 to 150 kVA.
The blocks make it heavy from the first module: 2,191.8 lb (994.2 kg) with one, 340 lb/ft² on 6.4 ft², and each 30 kVA module adds 52 lb. It ships in 26 cartons and one more for each module, so plan the delivery as well as the floor. Where the batteries can stand in a room of their own, the CIRRO frames take the same 480 V load on an external bank.
Drag to turnThe same on every CIRRO-IB:The CIRRO-IB display
Efficiency
How efficient is the CIRIB150-5X30 at your load?
The CIRIB150-5X30 in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.
- Load
- —
- Lost as heat
- —
- Heat to remove
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at per kWh
- —
From the 2026 catalog
What every CIRIB150 code shares
- Each 30 kVA power module, CIRIB-PWR-30: 52 lb (23.6 kg), hot-swappable
- Technology: 3-level IGBT; unity power factor (kVA = kW); 40 A settable charger.
- Input / Output: 480/277 V three-phase, 4-wire.
- Battery: internal hot-swappable VRLA, up to 240 × 12 V 9 Ah blocks.
- Efficiency: up to 96%.
- Display: 7-inch color touchscreen.
- Comms: RS-232, EPO and USB, standard.
- Warranty: 3 years on UPS · 2 years on VRLA batteries.
- Cabinet: 23.6" W × 39.3" D × 78.7" H (599 × 998 × 1,999 mm), the same for every code above
The lines every CIRRO-IB shares, from technology to warranty, are in the CIRRO-IB key facts.
Size and floor
How big it is
23.6" W × 39.3" D × 78.7" H (599 × 998 × 1,999 mm); from 2,191.8 lb (994.2 kg) to 2,399.8 lb (1,088.6 kg) net, code by code.
Floor load = net weight ÷ footprint, without batteries outside the cabinet.
Installation
The CIRIB150 takes the clearances, wiring, cable entry and breakers of every CIRRO-IB model, from its AEC US user manual: see them on the CIRRO-IB page.
Datasheet
CIRIB150 datasheet, code by code.
Every figure of the 5 codes in the AEC 2026 catalog. Compare them with every CIRRO-IB model.
| Model | CIRIB150-1X30 | CIRIB150-2X30 | CIRIB150-3X30 | CIRIB150-4X30 | CIRIB150-5X30 |
|---|---|---|---|---|---|
| Power | |||||
| Rated power (kVA) | 30 | 60 | 90 | 120 | 150 |
| Active power (kW) | 30 | 60 | 90 | 120 | 150 |
| Output power factor | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| Electrical | |||||
| Input / output | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) | 480 V three-phase, 4-wire (3P+N) |
| Topology | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X | Online double conversion, modular N+X |
| Efficiency, up to | 96% | 96% | 96% | 96% | 96% |
| Battery DC bus | 480 V DC | 480 V DC | 480 V DC | 480 V DC | 480 V DC |
| Battery and runtime | |||||
| Battery type | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) | VRLA (sealed lead-acid) |
| Battery configuration | Internal Tray System | Internal Tray System | Internal Tray System | Internal Tray System | Internal Tray System |
| Runtime at 50% load | 45 min | 14 min | 10.5 min | 6 min | 6 min |
| Runtime at 100% load | 14 min | 6 min | 3 min | 2 min | — |
| Mechanical | |||||
| Form factor | Modular | Modular | Modular | Modular | Modular |
| Dimensions W × D × H | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) | 23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm) |
| Net weight | 2,191.8 lb (994.2 kg) | 2,243.8 lb (1,017.8 kg) | 2,295.8 lb (1,041.4 kg) | 2,347.8 lb (1,065 kg) | 2,399.8 lb (1,088.6 kg) |
| Footprint | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) | 6.4 ft² (0.60 m²) |
| Shipping | |||||
| Cartons | 26 | 27 | 28 | 29 | 30 |
From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures may change; the order confirmation governs.
Downloads
The CIRRO-IB manuals and catalogs cover every model of the series, these codes included: download them from the CIRRO-IB page.
CIRRO-IB
Other CIRRO-IB models
The CIRRO-IB has this one model page; its datasheet sets every code side by side.
The CIRIB150 for your project
Send the load, the voltage and the minutes you need from the CIRIB150. We reply with the code, the batteries and the lead time.