LUMINA · 120V single-phase UPS

LUM2200RT-2U-LI LUMINA 2.2 kVA, 120V single-phase UPS

Lithium2.2 kVAOnline double conversion

The AEC LUMINA LUM2200RT-2U-LI is a 2.2 kVA / 1.98 kW online double-conversion UPS for 120 V single-phase loads, with internal LiFePO4 lithium batteries: 23 minutes at full load, 46 at half load. Kept at 80 % of its rating, it carries loads up to 1.6 kW.

2.2 kVA / 2 kWRating
17.2 × 24.2 × 3.4 inW × D × H
42.1 lbWeight
Lithium, internalBattery
AEC LUM2200RT-2U-LI, rendered from its 3D modelDrag to turn

In 3D

Look around the LUM2200RT-2U-LI

Runtime

LUMINA 2.2 kVA · LiFePO4, extended runtime at your load.

The same chart as the LUMINA page: this model in bold, the other set-ups faded behind it to compare. 2026 catalog, new batteries.

50 %
102050100200500100010%25%50%75%100%LUM1000RT-2U-LI, LUM1500RT-2U-LI, LUM2000RT-2U-LI, LUM3000RT-2U-LILUM2200RT-2U-LIminutes (log scale)
LUMINA 1 kVA · LiFePO4 inside and 3 more, same minutesLUMINA 2.2 kVA · LiFePO4, extended runtime

At 50 % of the rating

LUMINA 2.2 kVA

This model LiFePO4, extended runtime46 min

LUMINA 1 kVA

LiFePO4 inside27 min

LUMINA 1.5 kVA

LiFePO4 inside27 min

LUMINA 2 kVA

LiFePO4 inside27 min

LUMINA 3 kVA

LiFePO4 inside27 min
Table: this model at 25, 50, 75 and 100 % load
Model25% load50% load75% load100% load
LUMINA 2.2 kVA · LiFePO4, extended runtimeLUM2200RT-2U-LI98 min46 min34.5 min23 min

Every LUMINA set-up in one table

From the 2026 catalog

What is the LUM2200RT-2U-LI?

  • Output: 2,200 VA / 1,980 W (power factor 0.9).
  • Input: IEC C20 inlet, power cord with NEMA 5-20P plug supplied.
  • Battery: internal LiFePO4 lithium, 13.6 Ah · 979.2 Wh — 23 min at full load, 12–15 year life (3,000 cycles).
  • Efficiency: up to 92.6%.
  • Outlets: 6× NEMA 5-20R.

The lines every LUMINA shares, from technology to warranty, are in the LUMINA key facts and in the datasheet below.

Size and floor

How big it is

17.2" W × 24.2" D × 3.4" H (438 × 615 × 87 mm); 42.1 lb (19.1 kg) net. It ships in one carton of 21.5 × 29.5 × 9.6 in, 57.1 lb (25.9 kg) gross.

2.9 ft²footprint (0.27 m²)
15 lb/ft²floor load of the cabinet alone
Rack 2Uform factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

5′9″ FrontSide 17.24″24.21″3.43″

What is what

Inside the LUMINA, part by part.

Each number on the picture is named in the list.

Rear · 1 kVA

AEC LUMINA 1 kVA, rear panel in rack position: eight NEMA 5-15R outlets, circuit protector, C14 inlet, USB, EPO, battery connector, fan and intelligent slot
  1. Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
  2. Cooling fanOne fan on the 1 kVA; the air leaves at the rear.
  3. EPOEmergency power off contact.
  4. USB portTo a computer, for the monitoring and shutdown software.
  5. Circuit protectorThe input breaker: press it to reset after an overload.
  6. Input: C14 inletIEC C14 inlet for the supply cord.
  7. 8 × NEMA 5-15R outletsThe protected outputs, 120 V.
  8. Battery connectorDC input of the internal battery.

Rear · 1.5–2.2 kVA

AEC LUMINA 1.5–2.2 kVA, rear panel in rack position: six NEMA 5-20R outlets, circuit protector, C20 inlet, USB, EPO, battery connector, two fans and intelligent slot
  1. Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
  2. Two cooling fansTwo fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
  3. EPOEmergency power off contact.
  4. USB portTo a computer, for the monitoring and shutdown software.
  5. Circuit protectorThe input breaker: press it to reset after an overload.
  6. Input: C20 inlet + 5 ft cordIEC C20 inlet; the 5 ft supply cord plugs in with its C19 connector.
  7. 6 × NEMA 5-20R outletsThe protected outputs, 120 V, 20 A receptacles.
  8. Battery connectorDC input of the internal battery.

Rear · 3 kVA

AEC LUMINA 3 kVA, rear panel in rack position: four NEMA 5-20R outlets, an L5-30R outlet, input cord, circuit protector, USB, EPO, battery connector, two fans and intelligent slot
  1. Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
  2. Two cooling fansTwo fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
  3. EPOEmergency power off contact.
  4. USB portTo a computer, for the monitoring and shutdown software.
  5. Circuit protectorThe input breaker: press it to reset after an overload.
  6. Input: NEMA L5-30P plugLocking 30 A plug on a 5 ft cord.
  7. 1 × NEMA L5-30R outletA locking 30 A output for the larger load.
  8. 4 × NEMA 5-20R outletsThe protected outputs, 120 V, 20 A receptacles.
  9. Battery connectorDC input of the internal battery.

Datasheet

LUM2200RT-2U-LI datasheet.

The LUM2200RT-2U-LI in the AEC 2026 catalog, figure by figure. Compare it with every LUMINA model.

LUM2200RT-2U-LI datasheet
ParameterLUM2200RT-2U-LI
Power
Rated power (kVA)2.2
Active power (kW)1.98
Output power factor0.9
Electrical
Input / output120 V single-phase
TopologyOnline Double Conversion
Efficiency, up to92.6%
Battery DC bus72 V DC
Battery and runtime
Battery typeLithium LiFePO4
Battery configurationInternal
Runtime at 50 % load46 min
Runtime at 100 % load23 min
Mechanical
Form factorRack 2U
Dimensions W × D × H17.2 × 24.2 × 3.4 in (438 × 615 × 87 mm)
Net weight42.1 lb (19.1 kg)
Footprint2.9 ft² (0.27 m²)
Shipping
Cartons1
Shipping weight57.1 lb
Common to every LUMINA
Battery, LUM2200RT-2U-LIinternal LiFePO4 lithium, 13.6 Ah · 979.2 Wh — 23 min at full load, 12–15 year life (3,000 cycles)
Displayrotating color LCD
CommsRS-232, EPO and USB, standard
Form factor2U rack; telescopic rail kit available
Network cardSNMP-L (SNMP)
Warranty5 years incl. lithium batteries
CertificationETL Listed to UL 1778 and CSA C22.2 No. 107.3
Quality systemISO 9001:2015, the group's quality system (SGS)

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

LUM2200RT-2U-LI: what people ask

How long does the LUM2200RT-2U-LI run on battery?

23 min at 100 % load (2.0 kW), 46 min at 50 % load (990 W), 3 h 56 min at 10 % load (198 W), from the catalog runtime table at the start of battery life. Runtime falls faster than the load rises, so the LUM2200RT-2U-LI chart above gives the minutes at any load in between.

What is the output current of the LUM2200RT-2U-LI?

18.3 A at 120 V at full load: 2.2 kVA ÷ 120 V. Size the input breaker and the cables of the LUM2200RT-2U-LI from its installation manual and the local electrical code, not from this figure alone.

How much heat does the LUM2200RT-2U-LI give off?

About 163 W, 560 BTU/h, at full load, where it is 92.4% efficient. Plan the room's cooling for a little more than that: the LUM2200RT-2U-LI is less efficient at part load and while its battery recharges.

How many rack units does the LUM2200RT-2U-LI take?

2U of a 19-inch rack: 3.4 in high, 24.2 in deep. Check the rack's usable depth, rails and rear clearance for the cables.

The method, for any UPS: runtime explained · amps from kVA · heat output in BTU/h

LUMINA

Other LUMINA models

The LUMINA series, with pictures

By power, the LUM2200RT-2U-LI is number 4 of 5 in the LUMINA series, which runs from 1 to 3 kVA. One size down is the LUM2000RT-2U-LI (0.2 kVA less and 12 lb lighter). One size up is the LUM3000RT-2U-LI (0.8 kVA more and 4 lb lighter).

Every LUMINA model side by side (5)
LUMINA models side by side
ModelPowerPower against this modelNet weightWeight against this modelRuntime at 50 % load
LUM1000RT-2U-LI1 kVA1.2 kVA less20 lb23 lb lighter27 min at 50 % load
LUM1500RT-2U-LI1.5 kVA0.7 kVA less32 lb10 lb lighter27 min at 50 % load, AEC estimate
LUM2000RT-2U-LI2 kVA0.2 kVA less30 lb12 lb lighter27 min at 50 % load
LUM2200RT-2U-LI2.2 kVAthis page42 lbthis page46 min at 50 % load
LUM3000RT-2U-LI3 kVA0.8 kVA more38 lb4 lb lighter27 min at 50 % load

The LUM2200RT-2U-LI for your project

Send the load, the voltage and the minutes you need from the LUM2200RT-2U-LI. We reply with the configuration, the batteries and the lead time.