LUMINA · 120V single-phase UPS
LUM3000RT-2U-LI LUMINA 3 kVA, 120V single-phase UPS
The AEC LUMINA LUM3000RT-2U-LI is a 3 kVA / 2.7 kW online double-conversion UPS for 120 V single-phase loads, with internal LiFePO4 lithium batteries: 11 minutes at full load, 27 at half load. Kept at 80 % of its rating, it carries loads up to 2.2 kW.
Drag to turnThe same on every LUMINA:The LUMINA display
Runtime
LUMINA 3 kVA · LiFePO4 inside at your load.
The same chart as the LUMINA page: this model in bold, the other set-ups faded behind it to compare. 2026 catalog, new batteries.
At 50 % of the rating
LUMINA 3 kVA
This model LiFePO4 inside27 minLUMINA 1 kVA
LiFePO4 inside27 minLUMINA 1.5 kVA
LiFePO4 inside27 minLUMINA 2 kVA
LiFePO4 inside27 minLUMINA 2.2 kVA
LiFePO4, extended runtime46 minTable: this model at 25, 50, 75 and 100 % load
| Model | 25% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|
| LUMINA 3 kVA · LiFePO4 insideLUM3000RT-2U-LI | 55 min | 27 min | 19 min | 11 min |
Load by load
The LUM3000RT-2U-LI at 25, 50, 75 and 100 % load.
Its 2.7 kW rating in four steps, worked out from its own catalog figures.
| Load | On battery | Output current, at 120 V | Efficiency | Heat to remove | Heat to remove (BTU/h) |
|---|---|---|---|---|---|
| 25 % of the LUM3000RT-2U-LI, 675 W | 55 min on battery | 6.3 A at the output | 89.1 % efficient | 83 W of heat | 280 BTU/h to cool |
| 50 % of the LUM3000RT-2U-LI, 1.4 kW | 27 min on battery | 12.5 A at the output | 92.1 % efficient | 116 W of heat | 400 BTU/h to cool |
| 75 % of the LUM3000RT-2U-LI, 2.0 kW | 19 min on battery | 18.8 A at the output | 92.5 % efficient | 164 W of heat | 560 BTU/h to cool |
| 100 % of the LUM3000RT-2U-LI, 2.7 kW | 11 min on battery | 25.0 A at the output | 92.4 % efficient | 222 W of heat | 760 BTU/h to cool |
Current = kVA × load ÷ volts.
Heat = load × (100 ÷ efficiency − 1); 1 kW is 3,412 BTU/h.
Runtime from the catalog's table, with new batteries; between its points, read on a straight line.
Efficiency
How efficient is the LUM3000RT-2U-LI at your load?
The LUM3000RT-2U-LI in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.
- Load
- —
- Lost as heat
- —
- Heat to remove
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at per kWh
- —
Sizing
What load fits the LUM3000RT-2U-LI?
At 80 % load the LUM3000RT-2U-LI's runtime table gives about 17 min on battery, with new batteries.
At 1.4 kW, half its rating, it runs 27 min.
At the same 1.4 kW, the other LUMINA models:
- LUM2200RT-2U-LI: 37.9 min on battery, at 68 % of its rating.
From the 2026 catalog
What is the LUM3000RT-2U-LI?
- Output: 3,000 VA / 2,700 W (power factor 0.9).
- Battery: internal LiFePO4 lithium, 10.2 Ah · 734.4 Wh — 11 min at full load, against 4.2 min for the VRLA FERRUS RT of the same kVA, each at its own full load, 12–15 year life (3,000 cycles).
- Efficiency: up to 92.5%.
- Outlets: 4× NEMA 5-20R + 1× NEMA L5-30R.
The lines every LUMINA shares, from technology to warranty, are in the LUMINA key facts and in the datasheet below.
Size and floor
How big it is
17.2" W × 22.4" D × 3.4" H (438 × 570 × 87 mm); 37.7 lb (17.1 kg) net. It ships in one carton of 21.5 × 27.7 × 9.6 in, 51.4 lb (23.3 kg) gross.
Floor load = net weight ÷ footprint, without batteries outside the cabinet.
Installation
The LUM3000RT-2U-LI takes the clearances, wiring, cable entry and breakers of every LUMINA model, from its AEC US user manual: see them on the LUMINA page.
Place the LUM3000RT-2U-LI in your room, to the inch, with Room fit
What is what
Inside the LUMINA, part by part.
Each number on the picture is named in the list.
Rear · 1 kVA
12345678- Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
- Cooling fanOne fan on the 1 kVA; the air leaves at the rear.
- EPOEmergency power off contact.
- USB portTo a computer, for the monitoring and shutdown software.
- Circuit protectorThe input breaker: press it to reset after an overload.
- Input: C14 inletIEC C14 inlet for the supply cord.
- 8 × NEMA 5-15R outletsThe protected outputs, 120 V.
- Battery connectorDC input of the internal battery.
Rear · 1.5–2.2 kVA
12345678- Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
- Two cooling fansTwo fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
- EPOEmergency power off contact.
- USB portTo a computer, for the monitoring and shutdown software.
- Circuit protectorThe input breaker: press it to reset after an overload.
- Input: C20 inlet + 5 ft cordIEC C20 inlet; the 5 ft supply cord plugs in with its C19 connector.
- 6 × NEMA 5-20R outletsThe protected outputs, 120 V, 20 A receptacles.
- Battery connectorDC input of the internal battery.
Rear · 3 kVA
123456789- Intelligent slotFor an SNMP network card or a dry-contact card; the -NC models ship with the SNMP card fitted.
- Two cooling fansTwo fans on the 1.5, 2, 2.2 and 3 kVA; the air leaves at the rear.
- EPOEmergency power off contact.
- USB portTo a computer, for the monitoring and shutdown software.
- Circuit protectorThe input breaker: press it to reset after an overload.
- Input: NEMA L5-30P plugLocking 30 A plug on a 5 ft cord.
- 1 × NEMA L5-30R outletA locking 30 A output for the larger load.
- 4 × NEMA 5-20R outletsThe protected outputs, 120 V, 20 A receptacles.
- Battery connectorDC input of the internal battery.
Datasheet
LUM3000RT-2U-LI datasheet.
The LUM3000RT-2U-LI in the AEC 2026 catalog, figure by figure. Compare it with every LUMINA model.
| Parameter | LUM3000RT-2U-LI |
|---|---|
| Power | |
| Rated power (kVA) | 3 |
| Active power (kW) | 2.7 |
| Output power factor | 0.9 |
| Electrical | |
| Input / output | 120 V single-phase |
| Topology | Online Double Conversion |
| Efficiency, up to | 92.5% |
| Battery DC bus | 72 V DC |
| Battery and runtime | |
| Battery type | Lithium LiFePO4 |
| Battery configuration | Internal |
| Runtime at 50 % load | 27 min |
| Runtime at 100 % load | 11 min |
| Mechanical | |
| Form factor | Rack 2U |
| Dimensions W × D × H | 17.2 × 22.4 × 3.4 in (438 × 570 × 87 mm) |
| Net weight | 37.7 lb (17.1 kg) |
| Footprint | 2.7 ft² (0.25 m²) |
| Shipping | |
| Cartons | 1 |
| Shipping weight | 51.4 lb |
| Common to every LUMINA | |
| Battery, LUM3000RT-2U-LI | internal LiFePO4 lithium, 10.2 Ah · 734.4 Wh — 11 min at full load, against 4.2 min for the VRLA FERRUS RT of the same kVA, each at its own full load, 12–15 year life (3,000 cycles) |
| Display | rotating color LCD |
| Comms | RS-232, EPO and USB, standard |
| Form factor | 2U rack; telescopic rail kit available |
| Network card | SNMP-L (SNMP) |
| Warranty | 5 years incl. lithium batteries |
| Certification | ETL Listed to UL 1778 and CSA C22.2 No. 107.3 |
| Quality system | ISO 9001:2015, the group's quality system (SGS) |
From the AEC 2026 catalog. Figures can change: the order confirmation rules.
Downloads
Manuals and catalogs.
The LUMINA documents cover every model of the series, this one included. PDF, in English.
Quick answers
LUM3000RT-2U-LI: what people ask
How long does the LUM3000RT-2U-LI run on battery?
11 min at 100 % load (2.7 kW), 27 min at 50 % load (1.4 kW), 2 h 5 min at 10 % load (270 W), from the catalog runtime table at the start of battery life. Runtime falls faster than the load rises, so the LUM3000RT-2U-LI chart above gives the minutes at any load in between.
What is the output current of the LUM3000RT-2U-LI?
25.0 A at 120 V at full load: 3.0 kVA ÷ 120 V. Size the input breaker and the cables of the LUM3000RT-2U-LI from its installation manual and the local electrical code, not from this figure alone.
How much heat does the LUM3000RT-2U-LI give off?
About 222 W, 760 BTU/h, at full load, where it is 92.4% efficient. Plan the room's cooling for a little more than that: the LUM3000RT-2U-LI is less efficient at part load and while its battery recharges.
How many rack units does the LUM3000RT-2U-LI take?
2U of a 19-inch rack: 3.4 in high, 22.4 in deep. Check the rack's usable depth, rails and rear clearance for the cables.
The method, for any UPS: runtime explained · amps from kVA · heat output in BTU/h
LUMINA
Other LUMINA models
By power, the LUM3000RT-2U-LI is the largest in the LUMINA series, which runs from 1 to 3 kVA. One size down is the LUM2200RT-2U-LI (0.8 kVA less and 4 lb heavier).
Every LUMINA model side by side (5)
| Model | Power | Power against this model | Net weight | Weight against this model | Runtime at 50 % load |
|---|---|---|---|---|---|
| LUM1000RT-2U-LI | 1 kVA | 2 kVA less | 20 lb | 18 lb lighter | 27 min at 50 % load |
| LUM1500RT-2U-LI | 1.5 kVA | 1.5 kVA less | 32 lb | 5 lb lighter | 27 min at 50 % load, AEC estimate |
| LUM2000RT-2U-LI | 2 kVA | 1 kVA less | 30 lb | 8 lb lighter | 27 min at 50 % load |
| LUM2200RT-2U-LI | 2.2 kVA | 0.8 kVA less | 42 lb | 4 lb heavier | 46 min at 50 % load |
| LUM3000RT-2U-LI | 3 kVA | this page | 38 lb | this page | 27 min at 50 % load |
Install and run it:LUMINA operating guide
The LUM3000RT-2U-LI for your project
Send the load, the voltage and the minutes you need from the LUM3000RT-2U-LI. We reply with the configuration, the batteries and the lead time.