RADIANT-IB · 208 V three-phase UPS

RADIB100 RADIANT-IB 100 kVA frame, 20–100 kVA fitted

VRLA20–100 kVA5 ordering codes

The AEC RADIANT-IB RADIB100 is a 100 kVA modular UPS frame for 208 V three-phase loads with five slots for 20 kVA hot-swappable power modules. The 2026 catalog lists it with 1, 2, 3, 4 or 5 modules fitted, 20–100 kVA in all; each code is a row below.

20–100 kVARating
23.6 × 39.3 × 78.7 inW × D × H
1,998–2,174 lbWeight, by code
VRLA, insideBattery

Series picture.

5 ordering codes

Which RADIB100 do you need?

One 100 kVA frame, a row per number of modules fitted. Only what changes from one code to the next is here; what they share is under the table.

RADIB100: the ordering codes and what changes from one to the next
Ordering codePowerFree slotsWith one module spare (N+1)Net weightFloor loadCurrent per phase at 208 VCartons
RADIB100-1X201 × 20 kVA power module3DAsk20 kVA / 20 kW4 of 5no spare with one module1,998 lb (906.3 kg)310 lb/ft²55.5 A26
RADIB100-2X202 × 20 kVA power modules3DAsk40 kVA / 40 kW3 of 520 kVA2,042 lb (926.2 kg)317 lb/ft²111 A27
RADIB100-3X203 × 20 kVA power modules3DAsk60 kVA / 60 kW2 of 540 kVA2,086 lb (946.2 kg)324 lb/ft²167 A28
RADIB100-4X204 × 20 kVA power modules3DAsk80 kVA / 80 kW1 of 560 kVA2,130 lb (966.2 kg)331 lb/ft²222 A29
RADIB100-5X205 × 20 kVA power modules3DAsk100 kVA / 100 kWnone of 580 kVA2,174 lb (986.1 kg)338 lb/ft²278 A30

This model

What sets the RADIB100 apart

The RADIANT-IB is a 100 kVA frame for 208 V three-phase that carries its own batteries: five slots for 20 kVA power modules and 240 blocks of 12 V 9 Ah on internal trays, in one 23.6 × 39.3 × 78.7 in cabinet. The catalog lists it with one to five modules, 20 to 100 kVA.

With its blocks it weighs 1,998 lb (906.3 kg) at 20 kVA and 2,174 lb (986.1 kg) at 100 kVA, 310 to 338 lb/ft² on 6.4 ft²: check the floor rating before it is placed. Each module adds 44 lb and 55.5 A per phase at full load. It is the 208 V counterpart of the CIRRO-IB.

AEC RADIB100-5X20, rendered from its 3D modelDrag to turn

In 3D

Look around the RADIB100-5X20

Efficiency

How efficient is the RADIB100-5X20 at your load?

The RADIB100-5X20 in normal double-conversion mode, from the 2026 catalog's efficiency curve. Drag along it to see the heat lost and its yearly cost.

—%

Load
—
Lost as heat
—
Heat to remove
—
Energy lost in a year, 24/7
—
Its cost in a year at per kWh
—

Every RADIANT-IB size on one curve

From the 2026 catalog

What every RADIB100 code shares

  • Each 20 kVA power module, RADIB-PWR-20: 44 lb (20 kg), hot-swappable
  • Technology: 3-level IGBT; unity power factor (kVA = kW); 40 A settable charger.
  • Input / Output: 208/120 V three-phase.
  • Battery: internal hot-swappable VRLA, up to 240 × 12 V 9 Ah blocks.
  • Efficiency: up to 94%.
  • Display: 7-inch color touchscreen.
  • Comms: RS-232, EPO and USB, standard.
  • Warranty: 3 years on UPS · 2 years on VRLA batteries.
  • Cabinet: 23.6" W × 39.3" D × 78.7" H (599 × 998 × 1,999 mm), the same for every code above

The lines every RADIANT-IB shares, from technology to warranty, are in the RADIANT-IB key facts.

Size and floor

How big it is

23.6" W × 39.3" D × 78.7" H (599 × 998 × 1,999 mm); from 1,998 lb (906.3 kg) to 2,174 lb (986.1 kg) net, code by code.

6.4 ft²footprint (0.60 m²)
338 lb/ft²floor load of the heaviest code
Modularform factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

5′9″ FrontSide 23.6″39.3″78.7″

Datasheet

RADIB100 datasheet, code by code.

Every figure of the 5 codes in the AEC 2026 catalog. Compare them with every RADIANT-IB model.

RADIANT-IB datasheet, 5 models
ModelRADIB100-1X20RADIB100-2X20RADIB100-3X20RADIB100-4X20RADIB100-5X20
Power
Rated power (kVA)20406080100
Active power (kW)20406080100
Output power factor1.01.01.01.01.0
Electrical
Input / output208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)208 V three-phase, 4-wire (3P+N)
TopologyOnline double conversion, modular N+XOnline double conversion, modular N+XOnline double conversion, modular N+XOnline double conversion, modular N+XOnline double conversion, modular N+X
Efficiency, up to94%94%94%94%94%
Battery DC bus240 V DC240 V DC240 V DC240 V DC240 V DC
Battery and runtime
Battery typeVRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)VRLA (sealed lead-acid)
Battery configurationInternal Tray SystemInternal Tray SystemInternal Tray SystemInternal Tray SystemInternal Tray System
Runtime at 50% load85 min32 min21.5 min14 min12 min
Runtime at 100% load32 min14 min8 min6 min3 min
Mechanical
Form factorModularModularModularModularModular
Dimensions W × D × H23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm)23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm)23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm)23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm)23.6 × 39.3 × 78.7 in (599 × 998 × 1,999 mm)
Net weight1,998 lb (906.3 kg)2,042 lb (926.2 kg)2,086 lb (946.2 kg)2,130 lb (966.2 kg)2,174 lb (986.1 kg)
Footprint6.4 ft² (0.60 m²)6.4 ft² (0.60 m²)6.4 ft² (0.60 m²)6.4 ft² (0.60 m²)6.4 ft² (0.60 m²)
Shipping
Cartons2627282930

From the AEC 2026 catalog. Efficiency is the catalog's “up to” figure; runtimes are AEC's runtime tables with new batteries; weights are the unit alone, without batteries outside it. Figures may change; the order confirmation governs.

RADIANT-IB

Other RADIANT-IB models

The RADIANT-IB series, with pictures

The RADIANT-IB has this one model page; its datasheet sets every code side by side.

The RADIB100 for your project

Send the load, the voltage and the minutes you need from the RADIB100. We reply with the code, the batteries and the lead time.