IST6 200–500 · Modular UPS

IST6-200, 4 × 50 kVA Hot-swappable modular UPS, 400 V

VRLA200 kVAmodular online UPS, 50 kVA modules

The IST6-200 is a single-column modular online UPS cabinet for up to four 50 kVA power modules: 200 kVA / 200 kW in 607 × 860 × 2000 mm. For data centres and critical buildings that grow in 50 kVA steps up to 200 kW per cabinet, or more with UPS in parallel.

200 kVA / 200 kWRating
607 × 860 × 2000 mmW × D × H
224 kg without modulesWeight

Quick answers

IST6-200, 4 × 50 kVA: quick answers

What it is
The IST6-200 is a single-column modular online UPS cabinet for up to four 50 kVA power modules: 200 kVA / 200 kW in 607 × 860 × 2000 mm.
Who it is for
For data centres and critical buildings that grow in 50 kVA steps up to 200 kW per cabinet, or more with UPS in parallel.
Supply and configuration
380 / 400 / 415 V
Battery and backup
±240 V DC nominal (±180 … ±300 V), 30–50 × 12 V blocks, standard 40
Size and weight
607 × 860 × 2000 mm · 224 kg without modules
Ordering code
IST6-200

IST6 200–500

What sets apart the IST6-200, 4 × 50 kVA

The IST6-200 is the narrowest way to 200 kW in the range: a 607 mm column, 224 kg without modules, holding a 3U bypass module of 200 kVA and four 50 kVA modules of 39 kg each (500 × 650 × 130 mm). The cabinet code is supplied without modules: order the IST6-50-J modules the load needs today.

Fully loaded it draws 345 A at the mains input (2 × (4 × 120) mm², 400 A 3P breaker), 303 A at bypass and output, and 434 A from a 40-block battery on 2 × (3 × 120) mm². It needs at least 2420 m³/h of cooling air, front to rear. Because all four slots carry power, redundancy at 200 kVA comes from a second UPS in parallel; at 150 kVA the fourth module is the N+1.

  • Against the IST6-300, 6 × 50 kVA (one size up): Power modules · rating 4 × 50 kVA against 6 × 50 kVA; Bypass module 200 kVA · 3U against 300 kVA · 3U; Weight without power modules 224 kg against 236 kg.

Planning data

IST6-200, 4 × 50 kVA: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST6-200, 4 × 50 kVA.

Four cabinets, one 50 kVA module

IST6-200, 4 × 50 kVA · Four cabinets, one 50 kVA module
Cabinet200 kVA
Power modules (50 kVA)4
Bypass module200 kVA · 3U
W × D × H (mm)607 × 860 × 2000
Weight without power modules224 kg
Mains input current345 A
Cooling air flow (min.)2420 m³/h

Site conditions and service

IST6-200, 4 × 50 kVA · Site conditions and service
Line200 kVA
Mains input345 A · 2×(4×120)
Bypass / output303 A · 2×(4×120)
Battery (40 blocks)434 A · 2×(3×120)
Mains breaker400 A 3P

Installation

Installing the IST6-200, 4 × 50 kVA: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

IST6-200, 4 × 50 kVA · installation
ItemFigureSource
Clearancesfront 800 mm, rear 500 mm, top 500 mm; left and right: not givenAEC user manual Table 3-1; EMEA 2026 catalogue p.157
Cable entryBottom (standard); Top (built to order)AEC user manual Table 3-1; EMEA 2026 catalogue p.157
Cooling air2,420 m³/hEMEA 2026 catalogue p.157
Heat at full load3.87 kW at 200 kW load, 98.1 % efficiencyIST6 200–500 data (up to 98.1 %, AEC); output PF 1 (EMEA 2026 catalogue)
Operating temperature0 to 40 °CIST6 200–500 AEC user manual
Switches and terminalsMains, bypass, maintenance bypass and output switches inside the front door (single column 1,148–1,711 mm up; double column on the left, 462–1,658 mm).IST6 200–500 user manual §3.5.1 p.43 (right-hand hinges, one door per column)
DoorOne leaf, hinged on the rightIST6 200–500 user manual §3.5.1 p.43 (right-hand hinges, one door per column)
Module withdrawal650 mm in front of the cabinet to withdraw a moduleEMEA 2026 catalogue p.143; AEC user manual A.2.1
Units in parallelUp to 8 unitsAEC user manual A.1.2; EMEA 2026 catalogue p.139

Size and floor

How big it is

607 × 860 × 2000 mm · 224 kg without modules.

0.52 m²footprint
2 mheight

1.75 mFrontSide6078602000

Efficiency

How efficient is the AEC IST6-200, 4 × 50 kVA at your load?

IST6-200, 4 × 50 kVA, 200 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 25%: 1.28 kW (η 97.5%) · 50%: 1.94 kW (η 98.1%) · 75%: 3.37 kW (η 97.8%) · 100%: 5.13 kW (η 97.5%). At 50% load, 24/7, it loses about 16,966 kWh a year.

98.1%50% · Typical curve, derived from the datasheet efficiency of 98.1% (AEC method)

How the curve is drawn and where each figure comes from: the IST6 200–500 range page. ECO and W-ECO modes are listed without an efficiency figure.

Load
—
Lost as heat
—
Energy lost in a year, 24/7
—
Its cost in a year at € per kWh
—
The catalogue's examples use €0.20 per kWh.
Where each figure comes from
ModeEfficiencyKindModelsSource
Online, double conversion25%: 97.5% · 50%: 98.1% · 75%: 97.8% · 100%: 97.5%Typical curve, derived from the datasheet efficiency of 98.1% (AEC method)allAEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape)
ECO99.2%Datasheet figure, load not statedallAEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape)

EMEA 2026 catalogue figures: Online, double conversion up to 98.1%.

AEC IST6-200, 4 × 50 kVA, rendered from its 3D model

In 3D

Look around the IST6-200, 4 × 50 kVA

Technical data

Technical data IST6-200, 4 × 50 kVA

Only this model's values, from the EMEA 2026 catalogue table.

IST6-200, 4 × 50 kVA · Technical data
Cabinet
Power modules · rating4 × 50 kVA
Bypass module200 kVA · 3U
Input
System · voltage3Ph+N+PE · 380 / 400 / 415 V; 138–485 V (full power 324–485 V, linear derating below)
Frequency · PF · THDi40–70 Hz · ≥ 0.99 · ≤ 1.5% at full load
Bypass304–438 V; synchronisation 50 ± 5 / 60 ± 6 Hz; settable window
Battery
Lead-acid±240 V DC nominal (±180 … ±300 V), 30–50 × 12 V blocks, standard 40
Lithium (with BMS card)±256 V DC nominal (±192 … ±294.4 V), 120–200 cells, standard 160
Charging currentup to 30 A × number of modules · cold start · shared battery
Output
System · voltage3Ph+N+PE (3Ph+PE optional) · 380 / 400 / 415 V ± 1%
Power factor · THDvsettable 0.8–1.0 (default 1.0) · ≤ 1% linear, ≤ 4% non-linear
Frequency · phase errortracks the bypass; 50 / 60 ± 0.1 Hz with mains abnormal · ≤ 1° balanced, ≤ 3° unbalanced
Transfermains ↔ battery 0 ms · bypass ↔ inverter < 1 ms synchronised, < 15 ms
Inverter overload (PF 1)≤ 105% continuous · 105–110% 60 min · 110–125% 10 min · 125–150% 1 min · > 150% to bypass
Bypass overload≤ 130% continuous · 130–150% 5 min · 150–200% 1 min · 200–300% 100 ms
System
Efficiency · modesup to 98.1% · ECO, WECO, source share, redundancy sleep
Parallelup to 8 UPS, current imbalance ≤ 5% · BSC dual bus and multi-bus (3 buses)
CommunicationModbus · RS232 · RS485 · 4 inputs / 3 outputs dry contact · options: SNMP, expansion, BMS
Environment0 … 40 °C · 0–95% RH · ≤ 2000 m (derating to 4000 m) · IP20 · < 70 dB · EMC C3
W × D × H (mm)607 × 860 × 2000
Weight without power modules224 kg
IST6-200, 4 × 50 kVA · Models
ItemIST6-200, 4 × 50 kVA
Power modules (50 kVA)4
Bypass module200 kVA · 3U
W × D × H (mm)607 × 860 × 2000
Weight without power modules224 kg
Mains input current345 A
Cooling air flow (min.)2420 m³/h

Power module 500 × 650 × 130 mm, 39 kg. Data from the IST6 200–500 kVA user manual. Specifications are subject to change without notice.

More technical detailshow it works, ordering codes

Diagrams

How the power flows: AEC IST6-200, 4 × 50 kVA

Pick an operating mode: the path the power takes to the load lights up.

Power module × NMaintenance bypassMainsRectifierDC busBatteryInverterStatic switchLoadStatic bypassPower module × NMaintenance bypassMainsRectifierDC busBatteryInverterStatic switchLoadStatic bypass

Normal. Double conversion: the rectifier feeds the DC bus, the inverter rebuilds a clean voltage and the load always runs on the inverter. The battery stays on charge. Efficiency up to 98.1% (double conversion, up to; ECO and WECO modes stated without a figure).

Modules and redundancy

Move the slider: the modules the load needs light up, and the spare slot holds the N+1 redundancy. Each slot takes one 50 kVA module.

modules working · redundant · free slot

Ordering codes

Ordering codes IST6-200, 4 × 50 kVA

Ordering codes IST6-200, 4 × 50 kVA
CodeDescription
IST6-200Modular cabinet, max. 4 × 50 kVA power modules, without modules
IST6-50-J50 kVA / 50 kW power module
PAR - IST6Parallel kit

Questions

Questions about the IST6-200, 4 × 50 kVA

How do I get N+1 with an IST6-200?

Run up to 150 kVA on three modules and fit the fourth as the redundant one, or parallel a second UPS (up to eight in a system, N+X between UPS). Redundancy sleep lets spare modules rest at light load.

What breaker and cables does an IST6-200 need?

A 400 A 3P mains breaker. Mains 345 A on 2 × (4 × 120) mm², bypass and output 303 A on 2 × (4 × 120) mm², battery 434 A (40 blocks) on 2 × (3 × 120) mm², copper at 90 °C, breakers valid for short-circuit currents below 65 kA.

How long does a 200 kVA UPS like the IST6-200, 4 × 50 kVA run?

3 to 156 minutes at full load (200 kW), and 8 to 311 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 40 × 12 V 100 Ah (IST6-200-40X100): 3 minutes at 100% and 8 at 50%. For other loads and batteries use the backup-time tool.

How big is the AEC IST6-200, 4 × 50 kVA and how much does it weigh?

The AEC IST6-200, 4 × 50 kVA measures 607 × 860 × 2000 mm; weight: 224 kg without modules (size from AEC's CAD drawing, weight from the EMEA 2026 catalogue).

What is the ordering code of the AEC IST6-200, 4 × 50 kVA?

In the EMEA 2026 catalogue the AEC IST6-200, 4 × 50 kVA is listed as IST6-200; AEC gives the full code, batteries included, from the load and the backup time.

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST6-200, 4 × 50 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.