INFINITE · 480V three-phase UPS

INF-100+1 INFINITE 100 kVA, 480V three-phase UPS

Lithium or VRLA100 kVAOnline double conversion

The AEC INFINITE INF-100+1 is a 100 kVA / 100 kW online double-conversion UPS for 480 V three-phase loads, built on two 100 kVA power modules (N+1), with external VRLA or lithium cabinets. Kept at 80 % of its rating, it carries loads up to 80 kW.

3-wire · Delta480 V 3-wire, delta: three phases and ground, no neutral

100 kVA / 100 kWRating
23.6 × 39.4 × 81.4 inW × D × H
571.3 lbWeight
VRLA or lithium, externalBattery
AEC INFINITE 100 kVA, 1 power module, rendered from its 3D modelDrag to turn

In 3D

Look around the INF-100+1

The turntable shows the 100 kVA, 1 power module configuration; the full 3D view opens on this model.

Runtime

The INF-100+1 with its batteries, at your load.

The INF-100+1 has no batteries of its own: the chart draws in bold the catalog set-ups built on it, the other INFINITE set-ups faded behind. The same chart as the INFINITE page. 2026 catalog, new batteries.

50 %
102050100200500100010%25%50%75%100%INF-100+L6-CAB-10x50LI, INF-200+1+L6-CAB-20x50LI, INF-200+L6-CAB-20x50LI, INF-400+2xL6-CAB-20x50LI, INF-600+3xL6-CAB-20x50LIINF-100+1+L6-CAB-20x50LI, INF-100+L6-CAB-20x50LIminutes (log scale)
INFINITE 100 kVA N+1 · 1 L6 cabinet, 20 lithium modules · INFINITE 100 kVA · 1 L6 cabinet, 20 lithium modulesINFINITE 100 kVA · half L6 cabinet, 10 modules and 4 more, same minutes
Table: this model at 25, 50, 75 and 100 % load
Model25% load50% load75% load100% load
INFINITE 100 kVA N+1 · 1 L6 cabinet, 20 lithium modulesINF-100+1+L6-CAB-20x50LI120 min60 min40 min30 min

Every INFINITE set-up in one table

From the 2026 catalog

What is the INF-100+1?

The code INF-100+1 orders these catalog items, shipped in 2 cartons:

  • 1 × INF-100: 100 kVA UPS, 23.6 × 39.4 × 81.4 in (600 × 1,000 × 2,068 mm), 452.2 lb (205.1 kg)
  • 1 × INFINITE-PWR-100: 100 kVA hot-swappable power module, 119 lb (54 kg)
  • Architecture: 2 × 100 kVA hot-swappable power modules in a 100 kVA frame.

Its other catalog lines are those of the INF-100, built in the same frame: see them on its page.

Size and floor

How big it is

23.6" W × 39.4" D × 81.4" H (600 × 1,000 × 2,068 mm); 571.3 lb (259.1 kg) net.

6.5 ft²footprint (0.60 m²)
88 lb/ft²floor load of the cabinet alone
Modularform factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

5′9″ FrontSide 23.62″39.37″81.42″

Datasheet

INF-100+1 datasheet.

The INF-100+1 in the AEC 2026 catalog, figure by figure. Compare it with every INFINITE model.

INF-100+1 datasheet
ParameterINF-100+1
Power
Rated power (kVA)100
Active power (kW)100
Output power factor1.0
Electrical
Input / output480 V three-phase, 3-wire (delta)
TopologyOnline double conversion, modular N+1
Efficiency, up to97.3%
Battery DC bus480 V DC
Battery and runtime
Battery typeVRLA or lithium LiFePO4
Battery configurationExternal VRLA bank or L6 lithium cabinets
Mechanical
Form factorModular
Dimensions W × D × H23.6 × 39.4 × 81.4 in (600 × 1,000 × 2,068 mm)
Net weight571.3 lb (259.1 kg)
Footprint6.5 ft² (0.60 m²)
Common to every INFINITE
Battery, INF-100+1external, lead-acid (30–50 blocks) or AEC L6 lithium cabinets
Technology, display, communications, warrantyAs on the INF-100 datasheet

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

INF-100+1: what people ask

What is the output current of the INF-100+1?

120.3 A per phase at full load: 100 kVA ÷ (√3 × 480 V). Size the input breaker and the cables of the INF-100+1 from its installation manual and the local electrical code, not from this figure alone.

How much heat does the INF-100+1 give off?

About 2.8 kW, 9,470 BTU/h, at full load, where it is 97.3% efficient. Plan the room's cooling for a little more than that: the INF-100+1 is less efficient at part load and while its battery recharges.

Will the INF-100+1 fit through a standard door?

Not upright through a standard 36 × 80-inch door, which clears about 79 in in height: at 81.4 in (2,068 mm) high it needs an opening taller than 81.4 in. Check elevators and the floor load on the way in too.

The method, for any UPS: runtime explained · amps from kVA · heat output in BTU/h

INFINITE

Other INFINITE models

The INFINITE series, with pictures

By power, the INF-100+1 is the smallest in the INFINITE series, which runs from 100 to 600 kVA. One size up are the INF-200, INF-200+1, INF-200+1+L6-CAB-20x50LI and INF-200+L6-CAB-20x50LI, all 100 kVA more. The same 100 kVA also comes as the INF-100, INF-100+1+L6-CAB-20x50LI, INF-100+L6-CAB-10x50LI and INF-100+L6-CAB-20x50LI: the table below gives each one's weight and battery.

Every INFINITE model side by side (13)
INFINITE models side by side
ModelPowerPower against this modelNet weightWeight against this modelBattery configuration
INF-100100 kVAthe same power452 lb119 lb lighterExternal VRLA bank or L6 lithium cabinets
INF-100+1100 kVAthis page571 lbthis pageExternal VRLA bank or L6 lithium cabinets
INF-100+1+L6-CAB-20x50LI100 kVAthe same power2,743 lb2,172 lb heavierExternal L6 lithium cabinets
INF-100+L6-CAB-10x50LI100 kVAthe same power1,808 lb1,237 lb heavierExternal L6 lithium cabinets
INF-100+L6-CAB-20x50LI100 kVAthe same power2,624 lb2,053 lb heavierExternal L6 lithium cabinets
INF-200200 kVA100 kVA more591 lb20 lb heavierExternal VRLA bank or L6 lithium cabinets
INF-200+1200 kVA100 kVA more710 lb139 lb heavierExternal VRLA bank or L6 lithium cabinets
INF-200+1+L6-CAB-20x50LI200 kVA100 kVA more2,882 lb2,311 lb heavierExternal L6 lithium cabinets
INF-200+L6-CAB-20x50LI200 kVA100 kVA more2,763 lb2,192 lb heavierExternal L6 lithium cabinets
INF-400400 kVA300 kVA more1,183 lb611 lb heavierExternal VRLA bank or L6 lithium cabinets
INF-400+2xL6-CAB-20x50LI400 kVA300 kVA more5,526 lb4,954 lb heavierExternal L6 lithium cabinets
INF-600600 kVA500 kVA more1,774 lb1,203 lb heavierExternal VRLA bank or L6 lithium cabinets
INF-600+3xL6-CAB-20x50LI600 kVA500 kVA more8,597 lb8,026 lb heavierExternal L6 lithium cabinets

The INF-100+1 for your project

Send the load, the voltage and the minutes you need from the INF-100+1. We reply with the configuration, the batteries and the lead time.