Comparisons

AEC and Socomec, datasheet by datasheet.

5 Socomec UPS sold in EMEA, each next to the AEC model that replaces it, figure by figure: rating, online and ECO efficiency, battery, size and weight. The Socomec figures are those of its own datasheets, the AEC figures those of the EMEA 2026 catalogue.

In short

What the two datasheets say

  • Online efficiency, where both datasheets give it (5 pairs): AEC higher in 4, Socomec higher in 1.
  • Weight is not compared row by row: each maker weighs something different (with or without the batteries inside). The table gives both figures.
  • A pair is a starting point, not an equal: runtime, options and test conditions differ. Compare the full datasheets before you choose.

Datasheets side by side

Socomec and AEC, model by model.

For each Socomec model, the figures of its own datasheet and, below it, the AEC model that replaces it with the figures of AEC's product data. A figure the datasheet does not give is "—".

ModelRatingOnline efficiencyECOBatterySize W × D × HWeight
ITYS 1 kVA (ITY3)ITYS 1–10 kVA1 kVA / 1 kW93%—sealed lead-acid, internal145 × 404 × 224 mm14.4 kg
AEC IST3-1IST3Datasheet · UPS finder1 kVA / 1 kW90.8%98.3%internal, 12 V 9 Ah blocks, 24 V; long backup model (-L): external145 × 357 × 226 mm8.5 kg with batteries; -L 4.6 kg, no battery
ITYS 3 kVA (ITY3)ITYS 1–10 kVA3 kVA / 3 kW93%—sealed lead-acid, internal192 × 428 × 322 mm26 kg
AEC IST3-J 3 kVAIST3-JDatasheet · UPS finder3 kVA / 3 kW93.3%98.3%internal, 12 V 9 Ah blocks, 72 V438 × 572 × 86 mm26 kg with batteries
ITYS 10 kVA (ITY3)ITYS 1–10 kVA10 kVA / 10 kW95%—sealed lead-acid, internal225 × 416 × 589 mm61 kg
AEC IST3-J 10 kVAIST3-JDatasheet · UPS finder10 kVA / 10 kW95.5%98.3%external, 192 V default (12–20 × 12 V settable)438 × 500 × 86 mm12.2 kg, no battery
Masterys BC+ 40 kVA (S4, internal battery)Masterys BC+ 10–160 kVA40 kVA / 40 kW95%99%VRLA (normal life), internal444 × 800 × 800 mm—
AEC IST7-40IST7 10–40Datasheet · UPS finder40 kVA / 40 kW96%99%lead-acid, external or inside (S model), ± 144 … ± 240 V DC300 × 842 × 1250 mm102.5 kg standard, no battery; 249.7 kg S model, with batteries
Masterys BC+ 80 kVA (T6, internal battery)Masterys BC+ 10–160 kVA80 kVA / 72 kW95%99%VRLA (normal life), internal600 × 855 × 1,930 mm—
AEC IST7-80IST7 60–200Datasheet · UPS finder80 kVA / 80 kW96.5%99%VRLA or lithium, external cabinets, ±192 V400 × 960 × 1193 mm163 kg, no battery

Socomec figures from the documents Socomec publishes on its own site, read between 8 and 13 November 2026; they may have changed since. Efficiency and weight depend on each maker's configuration and test conditions: compare the full datasheets before you choose.

Model by model

Each Socomec and its AEC

  • ITYS 1 kVA (ITY3) (1 kVA, ITYS 1–10 kVA) → AEC IST3-1: online efficiency 90.8% against 93%.
  • ITYS 3 kVA (ITY3) (3 kVA, ITYS 1–10 kVA) → AEC IST3-J 3 kVA: online efficiency 93.3% against 93%.
  • ITYS 10 kVA (ITY3) (10 kVA, ITYS 1–10 kVA) → AEC IST3-J 10 kVA: online efficiency 95.5% against 95%.
  • Masterys BC+ 40 kVA (S4, internal battery) (40 kVA, Masterys BC+ 10–160 kVA) → AEC IST7-40: online efficiency 96% against 95%.
  • Masterys BC+ 80 kVA (T6, internal battery) (80 kVA, Masterys BC+ 10–160 kVA) → AEC IST7-80: online efficiency 96.5% against 95%.

AEC against the other makers: AEC vs APC · AEC vs Eaton · AEC vs Vertiv · AEC vs Riello UPS · AEC vs Legrand

By size, with every maker: Single-phase UPS 1–3 kVA · Single-phase UPS 6–11 kVA · Three-phase UPS 10–40 kVA · Three-phase UPS 50–250 kVA

The AEC model for any other Socomec UPS

Questions

AEC vs Socomec

Which AEC UPS replaces the Socomec ITYS 1 kVA (ITY3)?

The AEC IST3-1 (IST3 range, 1 kVA / 1 kW), the model the UPS replacement tool gives for the ITYS 1 kVA (ITY3) (1 kVA, 1/1). Both sets of figures are in this page's table.

Which AEC UPS replaces the Socomec ITYS 3 kVA (ITY3)?

The AEC IST3-J 3 kVA (IST3-J range, 3 kVA / 3 kW), the model the UPS replacement tool gives for the ITYS 3 kVA (ITY3) (3 kVA, 1/1). Both sets of figures are in this page's table.

Where do the Socomec figures come from?

From the documents Socomec publishes on its own site (datasheets, brochures, specifications), read between 8 and 13 November 2026; each document is named at the foot of the page. A figure the datasheet does not give is "—", never estimated.

Sources

The Socomec documents read

  • ITYS 1 kVA (ITY3): maker catalogue pages (Socomec ITYS 1-10 kVA, DCG0066102, 2022, socomec.com), read 13 November 2026.
  • ITYS 3 kVA (ITY3): maker catalogue pages (Socomec ITYS 1-10 kVA, DCG0066102, 2022, socomec.com), read 13 November 2026.
  • ITYS 10 kVA (ITY3): maker catalogue pages (Socomec ITYS 1-10 kVA, DCG0066102, 2022, socomec.com), read 13 November 2026.
  • Masterys BC+ 40 kVA (S4, internal battery): maker product page, technical data (Socomec MASTERYS BC+ 10-160 kVA, socomec.com), read 13 November 2026.
  • Masterys BC+ 80 kVA (T6, internal battery): maker product page, technical data (Socomec MASTERYS BC+ 10-160 kVA, socomec.com), read 13 November 2026.

Other makers' names and model numbers are trademarks of their owners, used only to identify the models; AEC is not affiliated with them.

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need: we answer with the model and the batteries that fit.