IST3 · Single-phase UPS

IST3-1 Single-phase online UPS 1 kVA, tower, 230 V

VRLA1 kVAonline tower UPS, 230 V

The IST3-1 is a 1 kVA / 1000 W single-phase online double-conversion tower UPS with two internal 12 V 9 Ah batteries. For a workstation, a small server, a switch or a till: it plugs into a wall socket and feeds the loads from two Schuko outlets.

1 kVA / 1 kWRating
145 × 357 × 226 mmW × D × H
8.5 / 4.6 kgWeight
24 VBattery

Quick answers

IST3-1: quick answers

What it is
The IST3-1 is a 1 kVA / 1000 W single-phase online double-conversion tower UPS with two internal 12 V 9 Ah batteries.
Who it is for
For a workstation, a small server, a switch or a till: it plugs into a wall socket and feeds the loads from two Schuko outlets.
Supply and configuration
208 / 220 / 230 / 240 V
Battery and backup
24 V · 3 min at full load
Size and weight
145 × 357 × 226 mm · 8.5 / 4.6 kg
Ordering code
IST3-1-2X9 · IST3-1-L

IST3

What sets apart the IST3-1

The IST3-1 is the smallest AEC online UPS: 145 × 357 × 226 mm and 8.5 kg, so it sits under a desk or on a shelf. Its two 9 Ah blocks make a 24 V battery that gives 2 minutes at full load and 8 at half load in AEC's data (the catalogue prints 3 minutes), enough to ride through short outages and close files on a long one. The long backup version (IST3-1-L, 4.6 kg) has no internal batteries and runs on a 36 V external string instead.

Like the 2 and 3 kVA models it runs from the mains, not the battery, through brownouts: full load from 176 to 295 V, and down to 120 V when the load is below 50%. The battery is saved for real outages. Mains comes in through an IEC socket with a fuse; the rear also has USB, RS232, the EPO connector and the intelligent slot for an SNMP or RS485 / dry-contact card.

  • Against the IST3-2 (one size up): Power 1000 VA / 1000 W against 2000 VA / 2000 W; Voltage, standard model 24 V against 48 V; Voltage, long backup model 36 V against 72 V; Dimensions W × D × H, standard 145 × 357 × 226 against 190 × 397 × 330; Dimensions W × D × H, long backup 145 × 357 × 226 against 190 × 397 × 330.

Planning data

IST3-1: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST3-1.

Wall socket or terminal bar

IST3-1 · Wall socket or terminal bar
Model1 kVA
AC input max. (A)6
AC breaker (A)10
DC input max. (A, long backup)37
DC breaker (A)50
AC cable (mm²)1.5
Battery cable (mm²)6

Installation

Installing the IST3-1: space, cables

Each figure with its source.

IST3-1 · installation
ItemFigureSource
Clearancesrear 300 mm (recommended 500), left 300 mm (recommended 500), right 300 mm (recommended 500); front and top: not givenAEC IST3 user manual p.6 §1.2
Cable entryPlugs and sockets at the rearAEC IST3 user manual
Operating temperature−5 to 40 °C, best 20–25 °CAEC IST3 user manual p.6 §1.2
Switches and terminalsSockets, over-current protector and the battery connector on the rear panel.AEC IST3 user manual p.6 §1.2

Size and floor

How big it is

145 × 357 × 226 mm · 8.5 / 4.6 kg.

0.05 m²footprint
89–164 kg/m²floor load
0.23 mheight

Floor load = weight ÷ footprint: 89 kg/m² at the lowest weight given (4.6 kg), 164 kg/m² at the highest (8.5 kg).

1.75 mFrontSide145357226

Efficiency

How efficient is the AEC IST3-1 at your load?

IST3-1, 1 kW at its rating, online, double conversion (AEC's measured curve). Heat to remove on this curve: 50%: 0.06 kW (η 88.7%) · 75%: 0.08 kW (η 90.06%) · 100%: 0.10 kW (η 90.83%). At 50% load, 24/7, it loses about 558 kWh a year.

90.83%100% · Measured (AEC datasheet)

How the curve is drawn and where each figure comes from: the IST3 range page. The IST3 pages of the EMEA 2026 catalogue give no efficiency figure. The 1, 2 and 3 kVA curves are the ones AEC measured on the IST3-J of the same rating (AEC technical datasheet IST3-J 1–3 kVA), which AEC states has the same electronics; the 6 and 10 kVA curve has the same shape, moved to their 95.5% figure.

Load
—
Lost as heat
—
Energy lost in a year, 24/7
—
Its cost in a year at € per kWh
—
The catalogue's examples use €0.20 per kWh.
Where each figure comes from
ModeEfficiencyKindModelsSource
Online, double conversion30%: 86.14% · 50%: 88.7% · 75%: 90.06% · 100%: 90.83%Measured (AEC datasheet)IST3-1AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
ECO98.3%Datasheet figure, load not statedallAEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
Online, double conversion30%: 89.36% · 50%: 91.23% · 75%: 92.16% · 100%: 92.56%Measured (AEC datasheet)IST3-2AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
Online, double conversion30%: 90.84% · 50%: 91.85% · 75%: 93.3% · 100%: 93.1%Measured (AEC datasheet)IST3-3AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
Online, double conversion30%: 93.04% · 50%: 94.05% · 75%: 95.5% · 100%: 95.3%Typical curve, derived from the datasheet efficiency of 95.5% (AEC method)IST3-6 · IST3-10AEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
AEC IST3-1, rendered from its 3D modelDrag to turn

In 3D

Look around the IST3-1

Technical data

Technical data IST3-1

Only this model's values, from the EMEA 2026 catalogue table.

IST3-1 · Technical data
Rating
Power (VA / W)1000 / 1000
Efficiency (AC/AC)up to 90.8% · 98.3% in ECO mode
Input
Voltage range176–295 V full load · 154–176 V load < 75% · 120–154 V load < 50%
Frequency · connection50 / 60 Hz ± 10%, self-adapting · single phase, L + N + PE
Output
Voltage220 V ± 2% (default) · 208 / 220 / 230 / 240 V settable from the panel
Frequency · waveform50 / 60 Hz ± 0.2% in battery mode · sine wave
Voltage distortionTHD < 3% (linear load)
Power factor · transfer time1.0 (kVA = kW) · 0 ms mains to battery
Overload100–130% 1 min · 130–150% 1 s · > 150% 200 ms
Battery
Voltage, standard model24 V
Voltage, long backup model36 V
Backup time, standard model3 min at full load
Charge recoverystandard model < 10 h · long backup: depends on the battery pack
General
CommunicationRS232 and USB standard · SNMP card or RS485 and dry-contact card optional · EPO
Protectionsbattery undervoltage, overload, short circuit, over-temperature, input overvoltage
Noise< 50 dB
Environment−5 … 40 °C · 0–95% RH non-condensing · ≤ 1000 m without derating
Dimensions W × D × H, standard145 × 357 × 226
Dimensions W × D × H, long backup145 × 357 × 226
Weight standard / long backup (kg)8.5 / 4.6
IST3-1 · Models
ItemIST3-1
VA / W1000 / 1000
Internal batteries2 × 9 Ah · 24 V
Backup, full / half load3 min
W × D × H (mm)145 × 357 × 226
kg8.5
Long backup: battery36 V
Long backup: kg4.6

Specifications are subject to change without notice.

More technical detailsordering codes

Ordering codes

Ordering codes IST3-1

Ordering codes IST3-1
CodeDescription
IST3-1-2X9 · IST3-2-4X9 · IST3-3-6X9Standard models with internal 12 V 9 Ah batteries (2, 4, 6)
IST3-1-L · IST3-2-L · IST3-3-LLong backup, external batteries only (36 / 72 / 96 V)
IST3-[kVA]-[n]X9UPS with battery cabinet BB1, BB2 or BB3, n × 12 V 9 Ah in total
DRYCNT-IST3/9 · SNMPDry-contact relay board · internal SNMP board
MBYP-3K · MBYP-6KExternal manual maintenance bypass, rack, max. 3 kVA · max. 10 kVA

Questions

Questions about the IST3-1

How long does the IST3-1 run on battery?

2 minutes at full load (1000 W) and 8 at half load with its two internal 12 V 9 Ah batteries, in AEC's data (the catalogue prints 3 minutes). For longer backup, a BB1 tower cabinet takes up to 6 × 12 V 9 Ah (code IST3-1-6X9), or the long backup model IST3-1-L runs on an external 36 V battery.

What breaker does the IST3-1 need upstream?

The catalogue gives 6 A maximum AC input current and a 10 A breaker, without leakage protection, on a 1.5 mm² cable for about 5 m. The long backup model draws up to 37 A from its battery, on a 50 A DC breaker and 6 mm² cable.

How long does a 1 kVA UPS like the IST3-1 run?

2 to 41 minutes at full load (1 kW), and 8 to 101 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 2 × 12 V 9 Ah (IST3-1-2X9): 2 minutes at 100% and 8 at 50%. For other loads and batteries use the backup-time tool.

How big is the AEC IST3-1 and how much does it weigh?

The AEC IST3-1 measures 145 × 357 × 226 mm; weight: 8.5 / 4.6 kg (size from AEC's CAD drawing, weight from the EMEA 2026 catalogue).

What is the ordering code of the AEC IST3-1?

In the EMEA 2026 catalogue the AEC IST3-1 is listed as IST3-1-2X9, IST3-1-L; AEC gives the full code, batteries included, from the load and the backup time.

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST3-1: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.