All-in-One · Three-phase UPS

All-in-One 20 kVA Lithium UPS cabinet 20 kVA, 3/3 and 3/1

Lithium20 kVAUPS + lithium in one cabinet

The All-in-One 20 kVA is one cabinet with an IST9 20 kVA UPS, distribution and maintenance bypass switches, and 2–8 × 50 Ah or 4 × 100 Ah lithium modules. For data rooms, offices, finance, transport and education sites with a three-phase supply and loads up to 20 kW that want lithium backup on a 0.6 m² footprint.

20 kVA / 20 kWRating
600 × 1000 × 1110 mmW × D × H
2–8 × 50 Ah or 4 × 100 Ah LFPBattery

Quick answers

All-in-One 20 kVA: quick answers

What it is
The All-in-One 20 kVA is one cabinet with an IST9 20 kVA UPS, distribution and maintenance bypass switches, and 2–8 × 50 Ah or 4 × 100 Ah lithium modules.
Who it is for
For data rooms, offices, finance, transport and education sites with a three-phase supply and loads up to 20 kW that want lithium backup on a 0.6 m² footprint.
Supply and configuration
3/3 · 3/1 · 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L (IST9, 3/3 · 3/1)
Battery and backup
2–8 × 50 Ah or 4 × 100 Ah LFP · 15–60 min at 20 kW (50 Ah) · 60 min at 20 kW, 200 min at 6 kW (4 × 100 Ah)
Size and weight
600 × 1000 × 1110 mm · 232 kg with 2 × 50 Ah, up to 460 kg with 8 × 50 Ah
Ordering code
AIO-20K-2X50 … AIO-20K-8X50 (2 to 8 × 50 Ah) · AIO-20K-4X100 (4 × 100 Ah)

All-in-One

What sets apart the All-in-One 20 kVA

There is one All-in-One: the 20 kVA, with the IST9 20 kVA inside, working 3/3 or 3/1. Mains, bypass and output are the only wires to run on site; the modules are connected to the UPS at the factory, and AEC sets their number and charge current (up to 10 A) at commissioning. In 3/3 the IST9 draws 35 A per phase on a 63 A 3P input breaker; in 3/1 the bypass and output carry 91 A on 125 A 1P breakers.

Each 50 Ah module gives up to 10 kW through its own DC/DC converter, so two of them already carry the full 20 kW: 15 minutes at 20 kW, 60 minutes with eight. The 100 Ah version always has four modules of 5 kW each: 23.0 kWh, 60 minutes at 20 kW and 200 minutes at 6 kW, in the same footprint and 108 kg lighter than eight 50 Ah modules.

Size and floor

How big it is

600 × 1000 × 1110 mm · 232 kg with 2 × 50 Ah, up to 460 kg with 8 × 50 Ah.

0.6 m²footprint
387–767 kg/m²floor load
1.11 mheight

Floor load = weight ÷ footprint: 387 kg/m² at the lowest weight given (232 kg), 767 kg/m² at the highest (460 kg).

1.75 mFrontSide60010001110

Backup time

How long does the AEC All-in-One 20 kVA run at your load?

AEC's backup times for every ordering code: the minutes AEC publishes from 50 to 100% load, AEC's calculator below 50% and for a string you compose. Pick a battery option: the curve redraws, and every point says where it comes from.

Load50% · 10 kW

Loading AEC's data…

Source: AEC EMEA product data: ordering codes, cabinets, blocks and strings, and the times AEC publishes from 50 to 100% load. Below 50%, AEC's calculator (W per cell = load ÷ 96% ÷ cells, read on a straight line between the columns of the battery maker's constant-power table at 1.70 V/cell), scaled to meet the published 50% figure. Lithium: published times only. All-in-One lithium modules: the catalogue's reference values, to be confirmed by actual measurement. New batteries, 25 °C. AEC checks every sizing.

Table: the All-in-One 20 kVA minutes at 20, 50, 80 and 100% load
All-in-One 20 kVA: backup time in minutes at the load shown (100% = 20 kW)
BatteriesCode20%50%80%100%
2 × lithium modules 50 AhAIO-20K-2X50—301915
8 × lithium modules 50 AhAIO-20K-8X50—1207560
4 × lithium modules 100 Ah——120—60

For each battery type the smallest and the largest configuration; new batteries, 25 °C. AEC published figures or EMEA 2026 catalogue figures. Every option is in the chart and the table of codes.

All 7 ordering codes of the All-in-One 20 kVA and their backup times
All-in-One 20 kVA: ordering codes and backup time in minutes at the load shown
CodeBatteriesCabinet100%90%80%70%60%50%
Lithium modules, 50 Ah
AIO-20K-2X502 × lithium modules 50 Ahinternal151719212530
AIO-20K-3X503 × lithium modules 50 Ahinternal222528323745
AIO-20K-4X504 × lithium modules 50 Ahinternal303338435060
AIO-20K-5X505 × lithium modules 50 Ahinternal374147536275
AIO-20K-6X506 × lithium modules 50 Ahinternal455056647590
AIO-20K-7X507 × lithium modules 50 Ahinternal5258657587105
AIO-20K-8X508 × lithium modules 50 Ahinternal60677586100120

Minutes from AEC EMEA product data: from 50 to 100% load, the times AEC publishes. The chart above adds AEC's calculation from 10 to 40%.

AEC All-in-One 20 kVA, rendered from its 3D modelDrag to turn

In 3D

Look around the All-in-One 20 kVA

Technical data

Technical data All-in-One 20 kVA

Only this model's values, from the EMEA 2026 catalogue table.

All-in-One 20 kVA · Technical data
Model
AEC codesAIO-20K-2X50 … AIO-20K-8X50 · AIO-20K-4X100
UPS insideIST9 20 kVA, rack 3U
Rated power (kVA / kW)20 / 20
Input / output3/3 · 3/1
Technologyonline double conversion · IGBT rectifier with PFC · DSP control · battery from isolated DC/DC lithium modules
Input
Voltage rangephase 176–280 V full load · 80–176 V with linear derating
Frequency40–70 Hz
Power factor · THDi≥ 0.99 · ≤ 3% resistive, ≤ 5% non-linear full load
Output
Voltage220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L · fine adjustment ± 5 V
Frequency on battery50 or 60 ± 0.1 Hz
Voltage distortion≤ 2% resistive full load
Power factor1.0 (kVA = kW)
Transfer time< 1 ms synchronised · < 10 ms not synchronised
Overload≤ 105% continuous · 105–110% 60 min · 110–130% 10 min · 130–155% 1 min · > 155% 200 ms
Efficiency (AC/AC)up to 96% · 99% in ECO mode
Modesonline · ECO · battery · bypass · generator · frequency converter · impact load · test load
Battery system
Lithium modules2 to 8 × 50 Ah (5.76–23.0 kWh) or 4 × 100 Ah (23.0 kWh)
Backup time15–60 min at 20 kW (50 Ah) · 60 min at 20 kW, 200 min at 6 kW (4 × 100 Ah)
Charge current, max.10 A (UPS charger); per module set from the number of modules
General
CommunicationRS232 · EPO · RS485 · options: SNMP, RS485 + dry contact
System display4.3" touch screen, tilted, on the door, with 3-colour LED status bar · LCD of the UPS · USB for records and upgrades
Noise< 65 dB at full load
Working temperature · humidityUPS −5 … 40 °C · battery 0–40 °C (15–30 °C recommended) · humidity 5–95%, non-condensing
Altitude · protection degree≤ 2000 m (above: derating to IEC 62040-3) · IP20
Earthing systemsTN-S · TN-C · TN-C-S
Cabinet size W × D × H (mm), on castors600 × 1000 × 1110 · 1000 mm high without castors
Cabinet weight with distribution, without UPS and modules (kg)138 ± 5 (50 Ah) · 134 ± 5 (100 Ah)
System weight (kg)232 (2 × 50 Ah) to 460 (8 × 50 Ah) · 352 (4 × 100 Ah)
UPS size W × D × H (mm)438 × 535 × 130 (3U)
UPS weight (kg)18.4
All-in-One 20 kVA · Models
ItemAll-in-One 20 kVA
UPS insideIST9 20 kVA
Input / output3/3 · 3/1
UPS height3U
Number of modules (from backup tables)50 Ah: 2–8 · 100 Ah: 4

UPS data from the IST9 user manual; system data from the AEC All-in-One 20 kVA user manual and the EMEA 2026 catalogue. Specifications are subject to change without notice.

More technical detailsrange tables, ordering codes

Planning data

All-in-One range tables

Eight codes, one 20 kVA system

Every code: IST9 20 kVA, input / output 3/3 or 3/1. Weight: UPS 18.4 kg + cabinet with distribution 138 ± 5 kg (134 ± 5 kg for 100 Ah) + modules of more than 38 kg (50 Ah) or 50 kg (100 Ah) each. Backup times: reference values, to be confirmed by actual measurement; AEC sizes every system.

All-in-One 20 kVA · Eight codes, one 20 kVA system
AEC codeLithium moduleskWhmin at 20 kWmin at 10 kWmin at 6 kWWeight (kg)
AIO-20K-2X502 × 50 Ah5.76153050232
AIO-20K-3X503 × 50 Ah8.64224575270
AIO-20K-4X504 × 50 Ah11.53060100308
AIO-20K-5X505 × 50 Ah14.43775125346
AIO-20K-6X506 × 50 Ah17.34590150384
AIO-20K-7X507 × 50 Ah20.252105175422
AIO-20K-8X508 × 50 Ah23.060120200460
AIO-20K-4X1004 × 100 Ah23.060120200352

50 Ah modules · minutes

Backup grows one module at a time: 2 to 8 modules of 50 Ah, 2.88 kWh each. Load in kW; backup in minutes. 6 kW: catalogue reference values at 25 °C; 10 to 20 kW (50 to 100% load): AEC's product data. To be confirmed by actual measurement; AEC sizes every system. –: configuration not possible (at least two modules).

All-in-One 20 kVA · 50 Ah modules · minutes
Load · modules12345678
6 kW–5075100125150175200
10 kW–3045607590105120
12 kW–253750627587100
14 kW–21324353647586
16 kW–19283847566575
18 kW–17253341505867
20 kW–15223037455260

100 Ah modules · minutes

Long backup with four 100 Ah modules, 23.0 kWh in all (AIO-20K-4X100); the 100 Ah version always has four. Catalogue reference values at 25 °C, to be confirmed by actual measurement. –: configuration not possible.

All-in-One 20 kVA · 100 Ah modules · minutes
Load · modules1234
6 kW–––200
10 kW–––120
20 kW–––60

One cabinet to connect · IST9 20 kVA max. steady-state current (A)

Only mains, bypass and output are wired on site; the lithium modules are already connected to the UPS inside the cabinet.

All-in-One 20 kVA · One cabinet to connect · IST9 20 kVA max. steady-state current (A)
kVAModeAC inBypassAC out
203/335—30
203/1359191

IST9 20 kVA · recommended breakers (A)

From the IST9 user manual. Breaker 1.5–2 × max. input current, without leakage protection.

All-in-One 20 kVA · IST9 20 kVA · recommended breakers (A)
kVAModeAC inBypassAC out
203/363 × 3P50 × 3P50 × 3P
203/163 × 3P125 × 1P125 × 1P

50 Ah or 100 Ah?

Same cabinet, same UPS: the module decides the backup. Catalogue reference values; AEC sizes every system.

All-in-One 20 kVA · 50 Ah or 100 Ah?
50 Ah100 Ah
Modules2 to 8, two per row4, one per row
Module width223 mm440 mm
Cells4C1C
Energy per module2.88 kWh5.76 kWh
Energy in all5.76–23.0 kWh23.0 kWh
Backup at 20 kW15–60 min60 min
System weight232–460 kg352 kg
Best forshort and medium backuplong backup, low and medium loads

Ordering codes

Ordering codes All-in-One 20 kVA

Ordering codes All-in-One 20 kVA
CodeDescription
AIO-20K-2X50IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 2 × 50 Ah lithium modules (5.76 kWh)
AIO-20K-3X50IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 3 × 50 Ah lithium modules (8.64 kWh)
AIO-20K-4X50IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 4 × 50 Ah lithium modules (11.5 kWh)
AIO-20K-5X50IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 5 × 50 Ah lithium modules (14.4 kWh)
AIO-20K-6X50IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 6 × 50 Ah lithium modules (17.3 kWh)
AIO-20K-7X50IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 7 × 50 Ah lithium modules (20.2 kWh)
AIO-20K-8X50IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 8 × 50 Ah lithium modules (23.0 kWh)
AIO-20K-4X100IST9 20 kVA (3/3 · 3/1), distribution switches with maintenance bypass, 4 × 100 Ah lithium modules (23.0 kWh), one per row
OptionsSNMP card · dry-contact card · extra 50 Ah modules, up to 8 per cabinet

Questions

Questions about the All-in-One 20 kVA

What backup does the All-in-One 20 kVA give?

At 20 kW: 15, 22, 30, 37, 45, 52 or 60 minutes with two to eight 50 Ah modules, and 60 minutes with four 100 Ah modules. At 6 kW: 50 to 200 minutes with 50 Ah modules, 200 minutes with the 100 Ah version. Reference values, confirmed by AEC for each system.

Is there a single-phase All-in-One, or one above 20 kVA?

No. The All-in-One is built as 20 kVA only, three-phase input, 3/3 or 3/1: the 3/1 mode feeds single-phase loads. For a single-phase supply look at the IST3, IST3-J or IST8; for lithium above 20 kVA, at the L6 cabinets with the IST7 60–200 kVA or the IST6.

Can modules be added later?

Yes, with 50 Ah modules, up to eight: each module has its own DC/DC converter, so new modules work beside the ones in service and go in with the load supplied. The 100 Ah version is always four modules.

What are the ordering codes of the All-in-One 20 kVA?

AIO-20K-2X50 to AIO-20K-8X50 with 2 to 8 modules of 50 Ah, and AIO-20K-4X100 with four modules of 100 Ah. Tell us the load and the backup time: AEC chooses the code.

Lithium All-in-One or UPS with VRLA batteries?

AEC's comparison in the catalogue: one cabinet instead of UPS plus battery cabinet, installed by one person in 30–60 minutes instead of two people in 2–4 hours. The lithium lasts 10+ years with 5,000 cycles at 50% depth of discharge against 3–5 years and about 500 cycles for VRLA.

How long does a 20 kVA UPS like the All-in-One 20 kVA run?

15 to 60 minutes at full load (20 kW), and 30 to 120 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 2 × lithium modules 50 Ah (AIO-20K-2X50): 15 minutes at 100% and 30 at 50%. For other loads and batteries use the backup-time tool.

How big is the AEC All-in-One 20 kVA and how much does it weigh?

The AEC All-in-One 20 kVA measures 600 × 1000 × 1110 mm; weight: 232 kg with 2 × 50 Ah, up to 460 kg with 8 × 50 Ah (EMEA 2026 catalogue).

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC All-in-One 20 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.