IST6-120 · Modular UPS
IST6-120, 2 × 30 kVA Modular UPS, 30 kVA modules
The IST6-120 with two 30 kVA power modules is a 60 kVA / 60 kW modular online UPS in a 0.52 m² cabinet, with room for two more modules and a redundancy slot. For server rooms and telecom or banking sites of 30 to 60 kW that want hot-swap modules and room to grow.
Quick answers
IST6-120, 2 × 30 kVA: quick answers
- What it is
- The IST6-120 with two 30 kVA power modules is a 60 kVA / 60 kW modular online UPS in a 0.52 m² cabinet, with room for two more modules and a redundancy slot.
- Who it is for
- For server rooms and telecom or banking sites of 30 to 60 kW that want hot-swap modules and room to grow.
- Supply and configuration
- 3 ph + N + PE · 220 / 230 / 240 V L-N · 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L
- Size and weight
- 600 × 860 × 2000 mm · 195 kg + 2 × 24 kg modules
- Ordering code
- IST6-120 + 2 × IST6-30-J (3 × for N+1)
IST6-120
What sets apart the IST6-120, 2 × 30 kVA
Two modules share a 60 kVA load equally, under digital control with no master and no slave. Add a third for N+1: with 60 kVA of load and three modules, any one of them can fail or be pulled out for service and the load stays on the inverter. The charger gives up to 20 A with two modules.
At light load, the redundancy sleep function (Smart mode › Sleep redundancy) lets spare modules rest within a sleep safety load set on the screen, with an alarm if the load goes above it. The cabinet is the same as at 120 kVA, so cables and switchgear are sized once.
Planning data
IST6-120, 2 × 30 kVA: currents, breakers, cables, batteries
The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST6-120, 2 × 30 kVA.
Power added one 30 kVA module at a time
| Load up to | Modules (N) | Modules for N+1 |
|---|---|---|
| 60 kVA | 2 | 3 |
Installation
Installing the IST6-120, 2 × 30 kVA: space, heat, cables
Each figure with its source. Heat is the power lost at the peak efficiency stated.
| Item | Figure | Source |
|---|---|---|
| Clearances | front 800 mm, rear 800 mm, top 500 mm; left and right: not given | IST6 user manual Fig. 3-2 p.44 |
| Cable entry | Bottom (standard); Top, with the top wiring accessory (cables up to 120 mm²) | IST6 user manual Fig. 3-2 p.44 |
| Heat at full load | 1.86 kW at 60 kW load, 97 % efficiency | EMEA 2026 catalogue p.109, 122; output PF 1 (EMEA 2026 catalogue) |
| Operating temperature | −5 to 40 °C | IST6 30–120 user manual |
| Switches and terminals | Mains, SPD and output switches (796 mm up) and bypass and maintenance bypass (549 mm up) inside the front door. | IST6 user manual Fig. 2-3 p.13, Fig. 3-2 p.44 |
| Door | One leaf, hinged on the right | IST6 user manual Fig. 2-3 p.13, Fig. 3-2 p.44 |
| Module withdrawal | 700 mm in front of the cabinet to withdraw a module | IST6 user manual Fig. 2-6 p.15; EMEA 2026 catalogue p.125–126 |
Size and floor
How big it is
600 × 860 × 2000 mm · 195 kg + 2 × 24 kg modules.
Floor load = weight ÷ footprint: cabinet and modules, 195 + 2 × 24 = 243 kg.
Efficiency
How efficient is the AEC IST6-120, 2 × 30 kVA at your load?
IST6-120, 2 × 30 kVA, 60 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 25%: 0.56 kW (η 96.4%) · 50%: 0.93 kW (η 97%) · 75%: 1.54 kW (η 96.7%) · 100%: 2.24 kW (η 96.4%). At 50% load, 24/7, it loses about 8,128 kWh a year.
How the curve is drawn and where each figure comes from: the IST6-120 range page.
- Load
- —
- Lost as heat
- —
- Energy lost in a year, 24/7
- —
- Its cost in a year at € per kWh
- —
- The catalogue's examples use €0.20 per kWh.
Where each figure comes from
| Mode | Efficiency | Kind | Models | Source |
|---|---|---|---|---|
| Online, double conversion | 25%: 96.4% · 50%: 97% · 75%: 96.7% · 100%: 96.4% | Typical curve, derived from the datasheet efficiency of 97% (AEC method) | all | AEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape) |
| ECO | 99% | Datasheet figure, load not stated | all |
EMEA 2026 catalogue figures: Online, double conversion up to 97% · ECO up to 99%.
Drag to turnIn 3D
Look around the IST6-120, 2 × 30 kVA
The turntable shows the IST6 120 kVA; the full 3D view opens on the IST6 60 kVA.
Technical data
Technical data IST6-120, 2 × 30 kVA
Only this model's values, from the EMEA 2026 catalogue table.
| General | |
|---|---|
| Model | IST6-120 with IST6-30-J power modules |
| Rated power | 30 to 120 kVA / kW in 30 kVA steps (1–4 modules) + 1 redundancy slot |
| Topology | online double conversion, modular, hot-swap power modules, removable bypass module |
| Input | |
| Connection · voltage | 3 ph + N + PE · 220 / 230 / 240 V L-N |
| Voltage range | 176–280 V full power · 80–176 V derated (linear load) |
| Frequency · power factor · THDi | 40–70 Hz · ≥ 0.99 · ≤ 2% resistive, ≤ 3% non-linear full load |
| Bypass | 220 / 230 / 240 V L-N; synchronisation 50 / 60 Hz ± 6 Hz |
| Battery | |
| Voltage · blocks | ±168 … ±276 V DC · ±14 … ±23 × 12 V (default ±16; below ±16 load 80%) |
| Charging current | 10 A × number of modules (max.) |
| Functions | cold start · standard / deep test · common battery · lithium with BMS card |
| Output | |
| Connection · voltage | 3 ph + N + PE · 220 / 230 / 240 V L-N, 380 / 400 / 415 V L-L |
| Power factor · THDv | 1 · ≤ 1% linear, ≤ 4% non-linear |
| Frequency · phase error | tracks the bypass; 50 / 60 Hz ± 0.2% without mains · ≤ 1° (balanced load) |
| Transfer · dynamic response | 0 ms synchronised, < 15 ms not synchronised · < 5% for 0↔100% step |
| Inverter overload (PF 1) | ≤ 105% continuous · 106–110% 60 min · 111–125% 10 min · 126–150% 1 min · > 151% to bypass |
| Bypass overload | < 130% continuous · 131–150% 5 min · 151–200% 1 s · 201–300% 100 ms |
| Unbalanced load | 100% |
| System | |
| Efficiency | 97% double conversion · up to 99% ECO |
| Display · records | 7" colour touch screen · 10,000 events · 5 LEDs · status light bar |
| Communication | Modbus · RS232 · RS485 · 4 dry-contact inputs, 3 outputs · options: SNMP, dry-contact expansion, BMS card |
| Parallel | with parallel kit, ring cables; BSC dual bus |
| Environment | −5 … 40 °C · 0–95% RH · ≤ 2000 m · IP20 · < 65 dB · EMC class C3 |
| Dimensions W × D × H | 600 × 860 × 2000 mm · cable entry bottom (top with accessory) |
| Weight | cabinet without power modules 195 kg · power module 24 kg · bypass module 17 kg |
| Item | IST6-120, 2 × 30 kVA |
|---|---|
| Modules (N) | 2 |
| Modules for N+1 | 3 |
Specifications are subject to change without notice.
More technical detailshow it works, ordering codes
Diagrams
How the power flows: AEC IST6-120, 2 × 30 kVA
Pick an operating mode: the path the power takes to the load lights up.
Normal. Double conversion: the rectifier feeds the DC bus, the inverter rebuilds a clean voltage and the load always runs on the inverter. The battery stays on charge. Efficiency up to 97%.
Battery. The mains fails: the battery feeds the DC bus and the inverter carries on without a break. The load does not notice. Transfer: mains → battery with no break; inverter ↔ bypass 0 ms synchronised.
Bypass. Overload or internal fault: the static switch moves the load to the bypass line, fed by the mains.
ECO. The load runs on the bypass and the inverter stands ready: if the mains leaves the set window, the load goes back to the inverter. Higher efficiency, less protection. Efficiency up to 99%.
Maintenance. The maintenance bypass feeds the load straight from the mains, so the UPS can be isolated for service without switching the load off.
Modules and redundancy
Move the slider: the modules the load needs light up, and the spare slot holds the N+1 redundancy. Each slot takes one 30 kVA module.
modules working · redundant · free slot
Ordering codes
Ordering codes IST6-120, 2 × 30 kVA
| Code | Description |
|---|---|
| IST6-120 | Modular cabinet, max. 4 × 30 kVA power modules, supplied without modules |
| IST6-30-J | 30 kVA / 30 kW power module |
| PAR - IST6 | Parallel kit |
Questions
Questions about the IST6-120, 2 × 30 kVA
How many modules for 60 kVA with redundancy?
Three: two carry the load (N = 2) and the third is the redundant one (N+1), as in the catalogue's table. Each module is 30 kVA / 30 kW, 2U and 24 kg.
Can a module be replaced with the load on?
Yes. Each module has a ready switch and RUN / ALARM / FAULT LEDs; a faulty module is isolated automatically and replaced online. Wait at least 10 minutes after removal before opening it; replacement by AEC or authorised personnel.
How big is the AEC IST6-120, 2 × 30 kVA and how much does it weigh?
The AEC IST6-120, 2 × 30 kVA measures 600 × 860 × 2000 mm; weight: 195 kg + 2 × 24 kg modules (EMEA 2026 catalogue).