OZ Power VRLA · Batteries and cabinets
OZ Power 12 V 9 Ah AGM VRLA battery for UPS
The OZ Power 12 V 9 Ah is a sealed AGM valve-regulated lead-acid block, 151 × 65 × 94 mm and 2.3 kg, the battery inside AEC single-phase UPS. For replacing or extending the batteries of IST3, IST3-J, IST9 and IST7 UPS and of the BB1–BB5 and BBJ cabinets.

Quick answers
OZ Power 12 V 9 Ah: quick answers
- What it is
- The OZ Power 12 V 9 Ah is a sealed AGM valve-regulated lead-acid block, 151 × 65 × 94 mm and 2.3 kg, the battery inside AEC single-phase UPS.
- Who it is for
- For replacing or extending the batteries of IST3, IST3-J, IST9 and IST7 UPS and of the BB1–BB5 and BBJ cabinets.
- Supply and configuration
- 12 V
- Battery and backup
- 8.4 · 9.0 Ah
- Size and weight
- 151 × 65 × 94 mm · 2.3 kg
- Ordering code
- OZ-1209 (OZ Power 12 V 9 Ah)
OZ Power VRLA
What sets apart the OZ Power 12 V 9 Ah
The 9 Ah belongs to the general-purpose series, with a design life of 6–8 years in float at 25 °C (the 40–200 Ah long-life series reach 12 years). Its capacity is rated at 20 hours (9.0 Ah) to 1.75 V per cell; at the UPS's usual end voltage it delivers 161 W per block for 15 minutes and 56.8 W for 1 hour. Internal resistance is ≤ 22 mΩ, the maximum charge current 2.7 A.
In the catalogue's sizing example, a 15 kW load on one string of 32 blocks needs 493 W per block, beyond what the 9 Ah gives for 5–10 minutes: it is a battery for single-phase UPS and small strings, or for long strings of 100–160 blocks in BB5 and BBJ2 cabinets.
- Against the OZ Power 12 V 24 Ah (one size up): Capacity C10 · C20 8.4 · 9.0 Ah against 22.4 · 24.0 Ah; Capacity C3 · C5 6.8 · 7.7 Ah against 18.0 · 20.4 Ah; L × W × H 151 × 65 × 94 mm against 166 × 175 × 125 mm; Total height 100 mm against 125 mm; Weight (approx.) 2.3 kg against 7.0 kg.
Planning data
OZ Power 12 V 9 Ah: currents, breakers, cables, batteries
The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the OZ Power 12 V 9 Ah.
Power when it matters
| W per 12 V block, 1.75 V/cell | 9 Ah |
|---|---|
| 15 min | 161 |
| 30 min | 100 |
| 60 min | 57 |
From load to backup time
| Battery | Backup time, 15 kW on 32 blocks |
|---|---|
| 12 V 9 Ah | below 5–10 min: not suitable for this load |
Size and floor
How big it is
151 × 65 × 94 mm · 2.3 kg.
Technical data
Technical data OZ Power 12 V 9 Ah
Only this model's values, from the EMEA 2026 catalogue table.
| OZ Power 12 V | |
|---|---|
| Capacity C10 · C20 | 8.4 · 9.0 Ah |
| Capacity C3 · C5 | 6.8 · 7.7 Ah |
| L × W × H (mm) | 151 × 65 × 94 |
| Total height (mm) | 100 |
| Weight (approx.) | 2.3 kg |
| Internal resistance | ≤ 22 mΩ |
| Terminal | F2 |
| Max. discharge (5 s) | 90 A |
| Short-circuit current | 450 A |
| Max. charge current | 2.7 A |
| Design life (float) | 6–8 years |
| Used in | IST3 · IST3-J · IST9 · IST7 · BB1–BB5 · BBJ · BBJ2 |
Values at 25 °C, fully charged, from the battery data sheets; C3–C20 = capacity at 3, 5, 10 and 20 h discharge (C3, C5 and C10 to 1.80 V/cell, C20 to 1.75 V/cell). Weight tolerance ± 5%. Terminal: default type, others optional. Specifications are subject to change without notice.
More technical detailsrange tables, ordering codes
Planning data
OZ Power VRLA range tables
12 V 9 Ah · constant power, W per 12 V block, 25 °C
AGM VRLA battery · design life 6–8 years in float · used in IST3 · IST3-J · IST9 · IST7 · BB1–BB5 · BBJ.
| End V/cell · V/block | 5 min | 10 min | 15 min | 30 min | 1 h | 2 h | 3 h | 4 h | 5 h | 8 h | 10 h | 20 h |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.60 V · 9.6 V | 350 | 251 | 185 | 110 | 62.0 | 38.4 | 29.1 | 23.6 | 19.6 | 12.8 | 10.5 | 5.50 |
| 1.65 V · 9.9 V | 329 | 242 | 179 | 107 | 60.2 | 37.3 | 28.3 | 23.1 | 19.2 | 12.7 | 10.4 | 5.50 |
| 1.70 V · 10.2 V | 304 | 227 | 170 | 103 | 58.6 | 36.3 | 27.7 | 22.5 | 18.8 | 12.5 | 10.2 | 5.40 |
| 1.75 V · 10.5 V | 278 | 211 | 161 | 99.7 | 56.8 | 35.2 | 26.9 | 22.0 | 18.4 | 12.4 | 10.1 | 5.30 |
| 1.80 V · 10.8 V | 249 | 195 | 151 | 96.3 | 55.0 | 34.1 | 26.2 | 21.5 | 17.9 | 12.2 | 10.0 | 5.30 |
| 1.85 V · 11.1 V | 202 | 162 | 127 | 83.8 | 49.6 | 31.4 | 24.3 | 20.0 | 16.8 | 11.5 | 9.40 | 5.00 |
12 V 9 Ah · constant current, A, 25 °C
Constant current discharge of the 12 V 9 Ah block, by end voltage and discharge time.
| End V/cell · V/block | 5 min | 10 min | 15 min | 30 min | 1 h | 2 h | 3 h | 4 h | 5 h | 8 h | 10 h | 20 h |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.60 V · 9.6 V | 35.2 | 24.6 | 17.6 | 10.1 | 5.50 | 3.38 | 2.54 | 2.05 | 1.70 | 1.09 | 0.89 | 0.47 |
| 1.65 V · 9.9 V | 32.7 | 23.3 | 16.9 | 9.72 | 5.31 | 3.27 | 2.46 | 1.99 | 1.65 | 1.08 | 0.88 | 0.46 |
| 1.70 V · 10.2 V | 29.5 | 21.4 | 15.8 | 9.29 | 5.14 | 3.16 | 2.39 | 1.94 | 1.61 | 1.06 | 0.86 | 0.46 |
| 1.75 V · 10.5 V | 26.4 | 19.6 | 14.7 | 8.88 | 4.95 | 3.05 | 2.32 | 1.89 | 1.57 | 1.05 | 0.85 | 0.45 |
| 1.80 V · 10.8 V | 23.2 | 17.7 | 13.6 | 8.48 | 4.76 | 2.94 | 2.25 | 1.83 | 1.53 | 1.03 | 0.84 | 0.45 |
| 1.85 V · 11.1 V | 18.4 | 14.5 | 11.2 | 7.31 | 4.27 | 2.69 | 2.08 | 1.71 | 1.43 | 0.97 | 0.79 | 0.42 |
Ordering codes
Ordering codes OZ Power 12 V 9 Ah
| Code | Description |
|---|---|
| OZ-1209 · OZ-1224 · OZ-1240 · OZ-1260 · OZ-1280 · OZ-12100 · OZ-12200 | OZ Power 12 V AGM VRLA blocks: 9 · 24 · 40 · 60 · 80 · 100 · 200 Ah |
Catalogue
This range's pages of the catalogue.
Questions
Questions about the OZ Power 12 V 9 Ah
How long can a 9 Ah block be stored?
Self-discharge is below 3% a month at 25 °C: recharge every 6 months in storage, or when the open-circuit voltage falls below 12.6 V.
Can I mix new 9 Ah blocks with old ones?
No. The catalogue asks for the same model, capacity and batch across the whole string when batteries are replaced.
How big is the AEC OZ Power 12 V 9 Ah and how much does it weigh?
The AEC OZ Power 12 V 9 Ah measures 151 × 65 × 94 mm; weight: 2.3 kg (EMEA 2026 catalogue).
Talk to an AEC engineer
Tell us the load, the supply and the backup time you need for the AEC OZ Power 12 V 9 Ah: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.