CIRRO · 480V three-phase UPS

CIR1200-12X100 CIRRO 1,200 kVA, 480V three-phase UPS

VRLA1,200 kVAOnline double conversion

The AEC CIRRO CIR1200-12X100 is a 1,200 kVA / 1,200 kW online double-conversion UPS for 480 V three-phase loads, built on 12 × 100 kVA power modules, with external battery cabinets. Kept at 80 % of its rating, it carries loads up to 960 kW.

All 12 module slots are fitted, so the frame is at its full 1,200 kVA; with one module held as a spare (N+1) it carries 1,100 kVA. As configured it weighs 2,618.9 lb (1,187.9 kg) net.

4-wire · 3P+N480 V 4-wire, wye: three phases, neutral and ground (277/480 V)

1,200 kVA / 1,200 kWRating
47.2 × 43.3 × 78.7 inW × D × H
2,618.9 lbWeight
VRLA, externalBattery

Load by load

The CIR1200-12X100 at 25, 50, 75 and 100 % load.

Its 1,200 kW rating in four steps, worked out from its own catalog figures.

At 25, 50, 75 and 100 % load
LoadOutput current per phase, at 480 VLoad on each of its 12 power modulesEfficiencyHeat to removeHeat to remove (BTU/h)
25 % of the CIR1200-12X100, 300 kW361 A per phase25 % on each module96.2 % efficient12 kW of heat40,430 BTU/h to cool
50 % of the CIR1200-12X100, 600 kW722 A per phase50 % on each module96.9 % efficient19 kW of heat65,490 BTU/h to cool
75 % of the CIR1200-12X100, 900 kW1,083 A per phase75 % on each module97.0 % efficient28 kW of heat94,970 BTU/h to cool
100 % of the CIR1200-12X100, 1,200 kW1,443 A per phase100 % on each module96.8 % efficient40 kW of heat135,350 BTU/h to cool

Current = kVA × load ÷ (√3 × volts).

Module load = load ÷ the kVA of the power modules fitted.

Heat = load × (100 ÷ efficiency − 1); 1 kW is 3,412 BTU/h.

From the 2026 catalog

What is the CIR1200-12X100?

The code CIR1200-12X100 orders these catalog items:

  • 1 × CIR1200-FRAME: 1,200 kVA frame, without power modules, 47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm)
  • 12 × CIR-PWR-100: 100 kVA hot-swappable power module, 103.6 lb (47 kg) each
  • Architecture: 12 × 100 kVA hot-swappable power modules in a 1,200 kVA / 1,200 kW frame (12 slots, scalable to 12 modules / 1,200 kVA); parallel up to 8 units.
  • Battery: external VRLA (battery bank sized separately). DC bus ±240 Vdc (480 Vdc total), 40 × 12 V blocks by default; selectable 30 to 50 blocks (±15 to ±25 per pole).
  • Switchgear: no breakers in the frame — external switchgear required for main input, output, bypass input and maintenance bypass.
  • Efficiency: up to 97%.

The lines every CIRRO shares, from technology to warranty, are in the CIRRO key facts and in the datasheet below.

12 × 100 kVA power modules fitted in a 12-slot frame: the frame is full.

Size and floor

How big it is

47.2" W × 43.3" D × 78.7" H (1,199 × 1,100 × 1,999 mm); 2,618.9 lb (1,187.9 kg) net.

14.2 ft²footprint (1.32 m²)
185 lb/ft²floor load of the cabinet alone
Modularform factor

Floor load = net weight ÷ footprint, without batteries outside the cabinet.

5′9″ FrontSide 47.2″43.3″78.7″

Datasheet

CIR1200-12X100 datasheet.

The CIR1200-12X100 in the AEC 2026 catalog, figure by figure. Compare it with every CIRRO model.

CIR1200-12X100 datasheet
ParameterCIR1200-12X100
Power
Rated power (kVA)1,200
Active power (kW)1,200
Output power factor1.0
Electrical
Input / output480 V three-phase, 4-wire (3P+N)
TopologyOnline double conversion, modular N+X
Efficiency, up to97%
Battery DC bus480 V DC
Battery and runtime
Battery typeVRLA (sealed lead-acid)
Battery configurationExternal battery bank
Mechanical
Form factorModular
Dimensions W × D × H47.2 × 43.3 × 78.7 in (1,199 × 1,100 × 1,999 mm)
Net weight2,618.9 lb (1,187.9 kg)
Footprint14.2 ft² (1.32 m²)
Common to every CIRRO
Technology3-level IGBT; unity power factor (kVA = kW); 80 A settable charger
Displaypersonalized AEC red color touchscreen
CommsRS232, RS485, USB, dry contacts, intelligent slot and EPO standard; battery cold start
Battery, CIR1200-12X100external VRLA (battery bank sized separately). DC bus ±240 Vdc (480 Vdc total), 40 x 12 V blocks by default; selectable 30 to 50 blocks (±15 to ±25 per pole)
Network cardSNMP-M (SNMP)
Warranty3 years on UPS · 2 years on VRLA batteries
Quality systemISO 9001:2015, the group's quality system (SGS)

From the AEC 2026 catalog. Figures can change: the order confirmation rules.

Quick answers

CIR1200-12X100: what people ask

What is the output current of the CIR1200-12X100?

1,443.4 A per phase at full load: 1,200 kVA ÷ (√3 × 480 V). Size the input breaker and the cables of the CIR1200-12X100 from its installation manual and the local electrical code, not from this figure alone.

How much heat does the CIR1200-12X100 give off?

About 40 kW, 135,350 BTU/h, at full load, where it is 96.8% efficient. Plan the room's cooling for a little more than that: the CIR1200-12X100 is less efficient at part load and while its battery recharges.

Will the CIR1200-12X100 fit through a standard door?

Not upright through a standard 36 × 80-inch door, which clears about 34 in: at 43.3 in (1,100 mm) across it needs an opening wider than 43.3 in. Check elevators and the floor load on the way in too.

The method, for any UPS: runtime explained · amps from kVA · heat output in BTU/h

CIRRO

Other CIRRO models

The CIRRO series, with pictures

By power, the CIR1200-12X100 is number 17 of 21 in the CIRRO series, which runs from 60 to 1,600 kVA. One size down is the CIR1200-11X100 (100 kVA less and 104 lb lighter). One size up is the CIR1600-13X100 (100 kVA more and 866 lb heavier).

Every CIRRO model side by side (21)
CIRRO models side by side
ModelPowerPower against this modelNet weightWeight against this model
CIR360-1X6060 kVA1,140 kVA less636 lb1,983 lb lighter
CIR600-1X100100 kVA1,100 kVA less997 lb1,622 lb lighter
CIR360-2X60120 kVA1,080 kVA less727 lb1,892 lb lighter
CIR360-3X60180 kVA1,020 kVA less817 lb1,802 lb lighter
CIR600-2X100200 kVA1,000 kVA less1,100 lb1,519 lb lighter
CIR360-4X60240 kVA960 kVA less908 lb1,711 lb lighter
CIR360-5X60300 kVA900 kVA less998 lb1,621 lb lighter
CIR360-6X60360 kVA840 kVA less1,088 lb1,531 lb lighter
CIR600-4X100400 kVA800 kVA less1,307 lb1,312 lb lighter
CIR600-5X100500 kVA700 kVA less1,411 lb1,208 lb lighter
CIR600-6X100600 kVA600 kVA less1,515 lb1,104 lb lighter
CIR800-7X100700 kVA500 kVA less1,799 lb820 lb lighter
CIR800-8X100800 kVA400 kVA less1,902 lb717 lb lighter
CIR1200-9X100900 kVA300 kVA less2,308 lb311 lb lighter
CIR1200-10X1001,000 kVA200 kVA less2,412 lb207 lb lighter
CIR1200-11X1001,100 kVA100 kVA less2,515 lb104 lb lighter
CIR1200-12X1001,200 kVAthis page2,619 lbthis page
CIR1600-13X1001,300 kVA100 kVA more3,485 lb866 lb heavier
CIR1600-14X1001,400 kVA200 kVA more3,589 lb970 lb heavier
CIR1600-15X1001,500 kVA300 kVA more3,693 lb1,074 lb heavier
CIR1600-16X1001,600 kVA400 kVA more3,796 lb1,177 lb heavier

The CIR1200-12X100 for your project