IST6 400–1200 · Modular UPS

IST6-1200, 12 × 100 kVA Modular UPS, 400 V, for data centres

VRLA1200 kVAmodular online UPS, 100 kVA modules

The IST6-1200 is the largest AEC UPS: twelve 100 kVA modules in a double-column cabinet, 1.2 MW in 1.2 m² of floor. For large data centres and critical infrastructure with 1 to 1.2 MW per UPS, and up to 9.6 MW with eight in parallel.

1200 kVA / 1200 kWRating
1201 × 1000 × 2000 mmW × D × H
662 kg without modulesWeight

Quick answers

IST6-1200, 12 × 100 kVA: quick answers

What it is
The IST6-1200 is the largest AEC UPS: twelve 100 kVA modules in a double-column cabinet, 1.2 MW in 1.2 m² of floor.
Who it is for
For large data centres and critical infrastructure with 1 to 1.2 MW per UPS, and up to 9.6 MW with eight in parallel.
Supply and configuration
380 / 400 / 415 V
Battery and backup
480 V DC nominal (360–600 V), 30–50 × 12 V blocks, standard 40; neutral optional
Size and weight
1201 × 1000 × 2000 mm · 662 kg without modules
Ordering code
IST6-1200

IST6 400–1200

What sets apart the IST6-1200, 12 × 100 kVA

With all twelve slots used, the IST6-1200 draws 1982 A at the mains and needs 8785 m³/h of cooling air, the highest of the range. Eight units in parallel make 9.6 MW, with BSC dual-bus or three-bus layouts; a 7 m parallel cable comes with each UPS and the rings need N cables for N UPS.

Like every cabinet of the platform it runs without derating up to 40 °C, keeps 40% load with one fan failed and 15% with two, and records 200 ms of waveform before and after a fault. The energy storage mode lets the battery cut peaks and fill valleys on a plan curve.

  • Against the IST6-1000, 10 × 100 kVA (one size down): Power modules (100 kVA) 12 against 10.

Installation

Installing the IST6-1200, 12 × 100 kVA: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

IST6-1200, 12 × 100 kVA · installation
ItemFigureSource
Clearancesrear 800 mm; front, left, right and top: not givenIST6 400–1200 user manual §3.2.3 p.45; EMEA 2026 catalogue p.165 (600 kVA: 500 mm)
Cable entryTop (standard); Bottom, with the side wiring cabinetIST6 400–1200 user manual §3.2.3 p.45; EMEA 2026 catalogue p.165 (600 kVA: 500 mm)
Heat at full load34.6 kW at 1,200 kW load, 97.2 % efficiencyIST6 400–1200 AEC data; output PF 1 (EMEA 2026 catalogue)
Operating temperature0 to 40 °CIST6 400–1200 AEC user manual
Switches and terminals600 kVA: switches inside the UPS cabinet. 800–1200 kVA: in the 599 mm distribution cabinet on the left.IST6 400–1200 user manual §3.2.3 p.45; EMEA 2026 catalogue p.165 (600 kVA: 500 mm)
Module withdrawal760 mm in front of the cabinet to withdraw a moduleEMEA 2026 catalogue p.163, 180
Units in parallelUp to 8 unitsAEC IST6 400–1200 user manual; EMEA 2026 catalogue p.160–178

Size and floor

How big it is

1201 × 1000 × 2000 mm · 662 kg without modules.

1.2 m²footprint
2 mheight

1.75 mFrontSide120110002000

Efficiency

How efficient is the AEC IST6-1200, 12 × 100 kVA at your load?

IST6-1200, 12 × 100 kVA, 1,200 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 25%: 7.69 kW (η 97.5%) · 50%: 11.6 kW (η 98.1%) · 75%: 20.2 kW (η 97.8%) · 100%: 30.8 kW (η 97.5%). At 50% load, 24/7, it loses about 101,798 kWh a year.

98.1%50% · Typical curve, derived from the datasheet efficiency of 98.1% (AEC method)

How the curve is drawn and where each figure comes from: the IST6 400–1200 range page.

Load
—
Lost as heat
—
Energy lost in a year, 24/7
—
Its cost in a year at € per kWh
—
The catalogue's examples use €0.20 per kWh.
Where each figure comes from
ModeEfficiencyKindModelsSource
Online, double conversion25%: 97.5% · 50%: 98.1% · 75%: 97.8% · 100%: 97.5%Typical curve, derived from the datasheet efficiency of 98.1% (AEC method)allAEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape)
ECO99.2%Datasheet figure, load not statedall
W-ECO99%Datasheet figure, load not statedall

EMEA 2026 catalogue figures: Double conversion, General modules up to 97.2% · Double conversion, PLUS modules up to 98.1% · ECO up to 99.2% · W-ECO up to 99%.

AEC IST6-1200, 12 × 100 kVA, rendered from its 3D modelDrag to turn

In 3D

Look around the IST6-1200, 12 × 100 kVA

Technical data

Technical data IST6-1200, 12 × 100 kVA

Only this model's values, from the EMEA 2026 catalogue table.

IST6-1200, 12 × 100 kVA · Technical data
Cabinet
Power modules (100 kVA)12
Bypass module4.5U
Input
System · voltage3Ph+N+PE · 380 / 400 / 415 V; 138–485 V (full power 324–485 V, linear derating below)
Frequency · PF · THDi40–70 Hz · ≥ 0.99 · ≤ 3% at full load
Bypass304–438 V; synchronisation 50 / 60 ± 6 Hz; settable window
Battery
Lead-acid480 V DC nominal (360–600 V), 30–50 × 12 V blocks, standard 40; neutral optional
Lithium (with BMS card)512 V DC nominal (384–640 V), 120–200 cells, standard 160
Charging current20 A × number of modules · cold start · shared battery
Output
System · voltage3Ph+N+PE · 380 / 400 / 415 V ± 1%
Power factor · THDvsettable 0.8–1.0 (default 1.0) · ≤ 1% linear, ≤ 3% non-linear
Frequency · phase errortracks the bypass; 50 / 60 ± 0.1 Hz with mains abnormal · ≤ 1° balanced, ≤ 2° unbalanced
Transfermains ↔ battery 0 ms · bypass ↔ inverter < 1 ms synchronised, < 15 ms
Inverter overload (PF ≥ 0.95)≤ 105% continuous · 105–110% 60 min · 110–125% 10 min · 125–150% 1 min · > 150% to bypass
Bypass overload≤ 135% continuous · 135–150% 5 min · 150–200% 1 s · 200–300% 100 ms
System
Efficiency · modes97.2% (General) / 98.1% (PLUS) · ECO 99.2% · W-ECO 99% · energy storage, sleep, generator
Parallelup to 8 UPS, current imbalance ≤ 5% · BSC dual bus and multi-bus (3 buses)
CommunicationModbus · RS232 · RS485 · 4 inputs / 3 outputs dry contact · options: SNMP, expansion, BMS
Environment0 … 40 °C · 0–95% RH · ≤ 2000 m · IP20 · < 80 dB · EMC category C3
W × D × H (mm)1201 × 1000 × 2000
With distribution cabinet1800 mm wide
Weight without modules662 kg
IST6-1200, 12 × 100 kVA · Models
ItemIST6-1200, 12 × 100 kVA
Power modules (100 kVA)12
Columns · doors2 · 2
Internal power switchesoption¹
W × D (mm) · H 20001201 × 1000
Weight without modules662 kg
Mains input current1982 A
Cooling air flow (min.)8785 m³/h

Power module 440 × 760 × 130 mm (without ears and handles), 54 kg. Data from the IST6 400–1200 kVA user manual. Specifications are subject to change without notice.

More technical detailshow it works, ordering codes

Diagrams

How the power flows: AEC IST6-1200, 12 × 100 kVA

Pick an operating mode: the path the power takes to the load lights up.

Power module × NMaintenance bypassMainsRectifierDC busBatteryInverterStatic switchLoadStatic bypassPower module × NMaintenance bypassMainsRectifierDC busBatteryInverterStatic switchLoadStatic bypass

Normal. Double conversion: the rectifier feeds the DC bus, the inverter rebuilds a clean voltage and the load always runs on the inverter. The battery stays on charge. Efficiency up to 98.1% (PLUS modules; 97.2% with General modules).

Modules and redundancy

Move the slider: the modules the load needs light up, and the spare slot holds the N+1 redundancy. Each slot takes one 100 kVA module.

modules working · redundant · free slot

Ordering codes

Ordering codes IST6-1200, 12 × 100 kVA

Ordering codes IST6-1200, 12 × 100 kVA
CodeDescription
IST6-1200Modular cabinet, max. 12 × 100 kVA power modules, without modules
IST6-100-J100 kVA / 100 kW power module
PAR - IST6Parallel kit

Questions

Questions about the IST6-1200, 12 × 100 kVA

How many IST6-1200 can work in parallel?

Up to eight, for 9.6 MW, with current imbalance within 5% and N+X redundancy between UPS. Each UPS output is kept within ± 2 V and ± 0.1 Hz of the system setting.

What noise and environment does the IST6-1200 need?

Below 80 dB at 1 m from the front; 0–40 °C without derating, 0–95% humidity, up to 2000 m, IP20. It is not for open installations within 3.7 km of the sea.

How long does a 1200 kVA UPS like the IST6-1200, 12 × 100 kVA run?

3 to 26 minutes at full load (1,200 kW), and 8 to 52 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 240 × 12 V 100 Ah · 8 × 30 (IST6-1200-240X100): 3 minutes at 100% and 8 at 50%. For other loads and batteries use the backup-time tool.

How big is the AEC IST6-1200, 12 × 100 kVA and how much does it weigh?

The AEC IST6-1200, 12 × 100 kVA measures 1201 × 1000 × 2000 mm; weight: 662 kg without modules (EMEA 2026 catalogue).

What is the ordering code of the AEC IST6-1200, 12 × 100 kVA?

In the EMEA 2026 catalogue the AEC IST6-1200, 12 × 100 kVA is listed as IST6-1200; AEC gives the full code, batteries included, from the load and the backup time.

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST6-1200, 12 × 100 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.