IST6 400–1200 · Modular UPS

IST6-800, 8 × 100 kVA Modular UPS, 400 V, for data centres

VRLA800 kVAmodular online UPS, 100 kVA modules

The IST6-800 is a single-column modular online UPS for eight 100 kVA modules: 800 kW on 0.8 m², 801 × 1000 × 2000 mm. For large data centres that need the most power per square metre: 800 kW in one 801 mm column.

800 kVA / 800 kWRating
801 × 1000 × 2000 mmW × D × H
435 kg without modulesWeight

Quick answers

IST6-800, 8 × 100 kVA: quick answers

What it is
The IST6-800 is a single-column modular online UPS for eight 100 kVA modules: 800 kW on 0.8 m², 801 × 1000 × 2000 mm.
Who it is for
For large data centres that need the most power per square metre: 800 kW in one 801 mm column.
Supply and configuration
380 / 400 / 415 V
Battery and backup
480 V DC nominal (360–600 V), 30–50 × 12 V blocks, standard 40; neutral optional
Size and weight
801 × 1000 × 2000 mm · 435 kg without modules
Ordering code
IST6-800

IST6 400–1200

What sets apart the IST6-800, 8 × 100 kVA

The IST6-800 is the catalogue's density figure: 800 kW on 0.8 m², about 1 MW per square metre, at 435 kg without modules. To fit eight modules in one column it has no internal power switches: they come in the optional distribution cabinet fitted at the factory on the left (mains, bypass, maintenance bypass and output), which brings the line-up to 1400 mm.

From 800 kVA the top air outlet kit is factory fitted and the rear clearance grows to 800 mm. At full load the IST6-800 draws 1322 A at the mains and needs 7140 m³/h of air.

  • Against the IST6-600H, 6 × 100 kVA (one size down): Power modules (100 kVA) 8 against 6; Weight without modules 435 kg against 434 kg.
  • Against the IST6-1000, 10 × 100 kVA (one size up): Power modules (100 kVA) 8 against 10; W × D × H 801 × 1000 × 2000 mm against 1201 × 1000 × 2000 mm; With distribution cabinet 1400 mm wide against 1800 mm wide; Weight without modules 435 kg against 662 kg.

Installation

Installing the IST6-800, 8 × 100 kVA: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

IST6-800, 8 × 100 kVA · installation
ItemFigureSource
Clearancesrear 800 mm; front, left, right and top: not givenIST6 400–1200 user manual §3.2.3 p.45; EMEA 2026 catalogue p.165 (600 kVA: 500 mm)
Cable entryTop (standard); Bottom, with the side wiring cabinetIST6 400–1200 user manual §3.2.3 p.45; EMEA 2026 catalogue p.165 (600 kVA: 500 mm)
Cooling air7,140 m³/hIST6 400–1200 AEC data
Heat at full load23.0 kW at 800 kW load, 97.2 % efficiencyIST6 400–1200 AEC data; output PF 1 (EMEA 2026 catalogue)
Operating temperature0 to 40 °CIST6 400–1200 AEC user manual
Switches and terminals600 kVA: switches inside the UPS cabinet. 800–1200 kVA: in the 599 mm distribution cabinet on the left.IST6 400–1200 user manual §3.2.3 p.45; EMEA 2026 catalogue p.165 (600 kVA: 500 mm)
Module withdrawal760 mm in front of the cabinet to withdraw a moduleEMEA 2026 catalogue p.163, 180
Units in parallelUp to 8 unitsAEC IST6 400–1200 user manual; EMEA 2026 catalogue p.160–178

Size and floor

How big it is

801 × 1000 × 2000 mm · 435 kg without modules.

0.8 m²footprint
2 mheight

1.75 mFrontSide80110002000

Efficiency

How efficient is the AEC IST6-800, 8 × 100 kVA at your load?

IST6-800, 8 × 100 kVA, 800 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 25%: 5.13 kW (η 97.5%) · 50%: 7.75 kW (η 98.1%) · 75%: 13.5 kW (η 97.8%) · 100%: 20.5 kW (η 97.5%). At 50% load, 24/7, it loses about 67,865 kWh a year.

98.1%50% · Typical curve, derived from the datasheet efficiency of 98.1% (AEC method)

How the curve is drawn and where each figure comes from: the IST6 400–1200 range page.

Load
—
Lost as heat
—
Energy lost in a year, 24/7
—
Its cost in a year at € per kWh
—
The catalogue's examples use €0.20 per kWh.
Where each figure comes from
ModeEfficiencyKindModelsSource
Online, double conversion25%: 97.5% · 50%: 98.1% · 75%: 97.8% · 100%: 97.5%Typical curve, derived from the datasheet efficiency of 98.1% (AEC method)allAEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape)
ECO99.2%Datasheet figure, load not statedall
W-ECO99%Datasheet figure, load not statedall

EMEA 2026 catalogue figures: Double conversion, General modules up to 97.2% · Double conversion, PLUS modules up to 98.1% · ECO up to 99.2% · W-ECO up to 99%.

AEC IST6-800, 8 × 100 kVA, rendered from its 3D model

In 3D

Look around the IST6-800, 8 × 100 kVA

Technical data

Technical data IST6-800, 8 × 100 kVA

Only this model's values, from the EMEA 2026 catalogue table.

IST6-800, 8 × 100 kVA · Technical data
Cabinet
Power modules (100 kVA)8
Bypass module4.5U
Input
System · voltage3Ph+N+PE · 380 / 400 / 415 V; 138–485 V (full power 324–485 V, linear derating below)
Frequency · PF · THDi40–70 Hz · ≥ 0.99 · ≤ 3% at full load
Bypass304–438 V; synchronisation 50 / 60 ± 6 Hz; settable window
Battery
Lead-acid480 V DC nominal (360–600 V), 30–50 × 12 V blocks, standard 40; neutral optional
Lithium (with BMS card)512 V DC nominal (384–640 V), 120–200 cells, standard 160
Charging current20 A × number of modules · cold start · shared battery
Output
System · voltage3Ph+N+PE · 380 / 400 / 415 V ± 1%
Power factor · THDvsettable 0.8–1.0 (default 1.0) · ≤ 1% linear, ≤ 3% non-linear
Frequency · phase errortracks the bypass; 50 / 60 ± 0.1 Hz with mains abnormal · ≤ 1° balanced, ≤ 2° unbalanced
Transfermains ↔ battery 0 ms · bypass ↔ inverter < 1 ms synchronised, < 15 ms
Inverter overload (PF ≥ 0.95)≤ 105% continuous · 105–110% 60 min · 110–125% 10 min · 125–150% 1 min · > 150% to bypass
Bypass overload≤ 135% continuous · 135–150% 5 min · 150–200% 1 s · 200–300% 100 ms
System
Efficiency · modes97.2% (General) / 98.1% (PLUS) · ECO 99.2% · W-ECO 99% · energy storage, sleep, generator
Parallelup to 8 UPS, current imbalance ≤ 5% · BSC dual bus and multi-bus (3 buses)
CommunicationModbus · RS232 · RS485 · 4 inputs / 3 outputs dry contact · options: SNMP, expansion, BMS
Environment0 … 40 °C · 0–95% RH · ≤ 2000 m · IP20 · < 80 dB · EMC category C3
W × D × H (mm)801 × 1000 × 2000
With distribution cabinet1400 mm wide
Weight without modules435 kg
IST6-800, 8 × 100 kVA · Models
ItemIST6-800, 8 × 100 kVA
Power modules (100 kVA)8
Columns · doors1 · 1
Internal power switchesoption¹
W × D (mm) · H 2000801 × 1000
Weight without modules435 kg
Mains input current1322 A
Cooling air flow (min.)7140 m³/h

Power module 440 × 760 × 130 mm (without ears and handles), 54 kg. Data from the IST6 400–1200 kVA user manual. Specifications are subject to change without notice.

More technical detailshow it works, ordering codes

Diagrams

How the power flows: AEC IST6-800, 8 × 100 kVA

Pick an operating mode: the path the power takes to the load lights up.

Power module × NMaintenance bypassMainsRectifierDC busBatteryInverterStatic switchLoadStatic bypassPower module × NMaintenance bypassMainsRectifierDC busBatteryInverterStatic switchLoadStatic bypass

Normal. Double conversion: the rectifier feeds the DC bus, the inverter rebuilds a clean voltage and the load always runs on the inverter. The battery stays on charge. Efficiency up to 98.1% (PLUS modules; 97.2% with General modules).

Modules and redundancy

Move the slider: the modules the load needs light up, and the spare slot holds the N+1 redundancy. Each slot takes one 100 kVA module.

modules working · redundant · free slot

Ordering codes

Ordering codes IST6-800, 8 × 100 kVA

Ordering codes IST6-800, 8 × 100 kVA
CodeDescription
IST6-800Modular cabinet, max. 8 × 100 kVA power modules, without modules
IST6-100-J100 kVA / 100 kW power module
PAR - IST6Parallel kit

Questions

Questions about the IST6-800, 8 × 100 kVA

How wide is an IST6-800 with its switchgear?

801 mm for the UPS alone, 1400 mm with the optional distribution cabinet fitted on the left at the factory, which holds the mains, bypass, maintenance bypass and output switches.

How does the IST6-800 behave on a generator?

Power walk-in limits the inrush on the mains or generator, and in multi-UPS sites the rectifiers restart in sequence. Smart generator mode starts and stops the generator by dry contact and can take part of the power from the battery.

How long does a 800 kVA UPS like the IST6-800, 8 × 100 kVA run?

4 to 39 minutes at full load (800 kW), and 9 to 78 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 180 × 12 V 100 Ah · 6 × 30 (IST6-800-180X100): 4 minutes at 100% and 9 at 50%. For other loads and batteries use the backup-time tool.

How big is the AEC IST6-800, 8 × 100 kVA and how much does it weigh?

The AEC IST6-800, 8 × 100 kVA measures 801 × 1000 × 2000 mm; weight: 435 kg without modules (EMEA 2026 catalogue).