Technology · monitoring

UPS monitoring and communication: display, SNMP, Modbus, dry contacts

Every AEC UPS can tell people and machines how it is: on its own display, over a network card, and to a building management system by Modbus or dry contacts.

Range by range

Ports and network card.

The standard ports and the network card that fits, from the EMEA 2026 catalogue.

RangeStandard communicationNetwork cardDisplay
IST8USB + EPO + intelligent slot (RS232 + dry contact) standardSNMP card, optionalLCD, rack or tower reading
IST3RS232 + USB + EPO standardSNMP card, optionalLCD
IST3-JRS232 + EPO standard; USB on 1–3 kVASNMP card, optionalLCD, rack or tower reading (1–3 kVA)
All-in-OneRS485, RS232, EPO and USB on the touch screen standardSNMP card, optionaltilted system touch screen with 3-colour LED status bar
IST9RS232 + EPO standardSNMP card, optionaltouch screen that turns with the unit
IST7 10–40RS485, dry contacts, USB and two intelligent slots standardSNMP card, optionalcolour touch screen
IST7-TRS232 / RS485 Modbus RTU and 8 + 4 dry contacts standardSNMP card, optionaltouch screen
IST7 60–200Modbus RTU, RS232, RS485, 4 in / 3 out dry contacts, EPO and USB standardSNMP card, optionalcolour touch screen with ambient light bar
IST6-120Modbus, RS232, RS485, EPO and 4 in / 3 out dry contacts standardSNMP card, optional7-inch colour touch screen
IST6 200–500Modbus, RS232, RS485, EPO and 4 in / 3 out dry contacts standardSNMP card, optionalcolour touch screen
IST6 400–1200Modbus, RS232, RS485, EPO and 4 in / 3 out dry contacts standardSNMP card, optional7-inch colour touch screen
L6 LithiumRS485 to the UPS, TCP/IP (LAN) and EPO standardLAN port, standard10-inch touch screen (master cabinet)
SNMP network cardOptional on every AEC UPS range.Remote monitoring of input and output voltage, frequency and load, and remote ON / OFF over the network.In the intelligent slot on IST3, IST8, IST9 and IST7 10–40.
RS485 and dry-contact cardOptional on IST3, IST3-J, IST8 and IST9.Function: potential-free relay outputs for remote alarm signalling, plus an RS485 port.Installation: plug-in intelligent slot.
Dry contact expansion cardOptional on IST7 60–200, IST6-120, IST6 200–500 and IST6 400–1200.Function: +3 inputs and +2 outputs, for 7 inputs and 5 outputs in total.
BMS expansion cardOptional on IST7 60–200, IST6-120, IST6 200–500 and IST6 400–1200.Function: BMS port for lithium batteries, with charge- and discharge-disable inputs.
Lithium cabinet touch screenWork mode, status, current, voltage and SOC; the screen connects to the UPS over RS485 and to a network server over TCP/IP.
SNMP cardNetwork port and COM1 for a temperature and humidity sensor.