Where is AEC UPS in the United States?
AEC UPS USA LLC, 4872 SW 72 Avenue, Miami, FL 33155, phone +1 786 553 2100, with stock in a warehouse in Doral, Florida. The Miami team sizes systems and supports customers across the Americas.
Answered on About AEC
Which companies are in the AEC Group?
Allis Electric serves Asia and Oceania from Taipei. AEC International Srl, founded in Lainate near Milan in 1998 in partnership with Allis Electric, serves Europe, Africa and the Middle East. PHD PowerHouse is AEC in South Africa. AEC UPS USA LLC, in Miami, serves the United States and Latin America.
Answered on About AEC
Which card fits my UPS?
SNMP-L fits LUMINA, ETHERNO, AUREON, INFINITE, INFINITE 1.5MW; SNMP-M fits FERRUS, FERRUS RT, FERRUS SP, FERRUS SP RT, RADIANT, RADIANT-IB, CIRRO-IB, CIRRO.
Answered on UPS Monitoring Cloud
Which AEC UPS replaces an APC 120 V?
The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 1 APC model; 1.5 kVA: LUM1500RT-2U-LI against 2 APC models; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 1 APC model; 3 kVA: LUM3000RT-2U-LI against 3 APC models.
Answered on AEC vs APC
Which AEC UPS replaces an APC 208 V?
The AEC ETHERNO: 10 kVA: ETH10-1X50A-LI, ETH10-2X50A-LI, ETH10-3X50A-LI against 2 APC models; 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 2 APC models; 30 kVA: ETH30-3X50A-LI against 2 APC models. The AEC AUREON: 10 kVA: AUR10-40X9A, AUR10-80X9A against 2 APC models; 20 kVA: AUR20-60X9A, AUR20-80X9A against 2 APC models; 30 kVA: AUR30-80X9A against 2 APC models.
Answered on AEC vs APC
Which AEC UPS replaces a CyberPower 120 V?
The AEC LUMINA: 1.5 kVA: LUM1500RT-2U-LI against 1 CyberPower model; 3 kVA: LUM3000RT-2U-LI against 1 CyberPower model.
Answered on AEC vs CyberPower
Which AEC UPS replaces a Delta 120 V?
The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 2 Delta models; 1.5 kVA: LUM1500RT-2U-LI against 1 Delta model; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 2 Delta models; 3 kVA: LUM3000RT-2U-LI against 2 Delta models.
Answered on AEC vs Delta
Which AEC UPS replaces a Delta 208 V?
The AEC ETHERNO: 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 1 Delta model; 30 kVA: ETH30-3X50A-LI against 1 Delta model. The AEC AUREON: 20 kVA: AUR20-60X9A, AUR20-80X9A against 1 Delta model; 30 kVA: AUR30-80X9A against 1 Delta model.
Answered on AEC vs Delta
Which AEC UPS replaces an Eaton 120 V?
The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 1 Eaton model; 1.5 kVA: LUM1500RT-2U-LI against 3 Eaton models; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 1 Eaton model; 3 kVA: LUM3000RT-2U-LI against 3 Eaton models.
Answered on AEC vs Eaton
Which AEC UPS replaces an Eaton 208 V?
The AEC ETHERNO: 10 kVA: ETH10-1X50A-LI, ETH10-2X50A-LI, ETH10-3X50A-LI against 1 Eaton model; 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 1 Eaton model; 30 kVA: ETH30-3X50A-LI against 1 Eaton model. The AEC AUREON: 10 kVA: AUR10-40X9A, AUR10-80X9A against 1 Eaton model; 20 kVA: AUR20-60X9A, AUR20-80X9A against 1 Eaton model; 30 kVA: AUR30-80X9A against 1 Eaton model.
Answered on AEC vs Eaton
Which AEC UPS replaces a Toshiba 120 V?
The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 1 Toshiba model; 1.5 kVA: LUM1500RT-2U-LI against 1 Toshiba model; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 1 Toshiba model; 3 kVA: LUM3000RT-2U-LI against 1 Toshiba model.
Answered on AEC vs Toshiba
Which AEC UPS replaces a Toshiba 208 V?
The AEC ETHERNO: 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 2 Toshiba models; 30 kVA: ETH30-3X50A-LI against 2 Toshiba models.
Answered on AEC vs Toshiba
Which AEC UPS replaces a Toshiba Modular three-phase UPS, 208 V?
The AEC RADIANT: 15 to 30 kVA: RAD90-1X15, RAD90-2X15, RADIB100-1X20 against 2 Toshiba models.
Answered on AEC vs Toshiba
Which AEC UPS replaces a Tripp Lite 120 V?
The AEC LUMINA: 1.5 kVA: LUM1500RT-2U-LI against 1 Tripp Lite model; 3 kVA: LUM3000RT-2U-LI against 1 Tripp Lite model.
Answered on AEC vs Tripp Lite
Which AEC UPS replaces a Vertiv 120 V?
The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 1 Vertiv model; 1.5 kVA: LUM1500RT-2U-LI against 3 Vertiv models; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 1 Vertiv model; 3 kVA: LUM3000RT-2U-LI against 3 Vertiv models.
Answered on AEC vs Vertiv
Which AEC UPS replaces a Vertiv 208 V?
The AEC ETHERNO: 10 kVA: ETH10-1X50A-LI, ETH10-2X50A-LI, ETH10-3X50A-LI against 4 Vertiv models; 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 6 Vertiv models; 30 kVA: ETH30-3X50A-LI against 5 Vertiv models. The AEC AUREON: 10 kVA: AUR10-40X9A, AUR10-80X9A against 3 Vertiv models; 20 kVA: AUR20-60X9A, AUR20-80X9A against 5 Vertiv models; 30 kVA: AUR30-80X9A against 4 Vertiv models.
Answered on AEC vs Vertiv
Which AEC UPS replaces an Xtreme Power 120 V?
The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 3 Xtreme Power models; 1.5 kVA: LUM1500RT-2U-LI against 4 Xtreme Power models; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 3 Xtreme Power models; 3 kVA: LUM3000RT-2U-LI against 4 Xtreme Power models.
Answered on AEC vs Xtreme Power
Which AEC UPS replaces an Xtreme Power 208 V?
The AEC ETHERNO: 10 kVA: ETH10-1X50A-LI, ETH10-2X50A-LI, ETH10-3X50A-LI against 2 Xtreme Power models; 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 2 Xtreme Power models; 30 kVA: ETH30-3X50A-LI against 2 Xtreme Power models. The AEC AUREON: 10 kVA: AUR10-40X9A, AUR10-80X9A against 1 Xtreme Power model; 20 kVA: AUR20-60X9A, AUR20-80X9A against 1 Xtreme Power model; 30 kVA: AUR30-80X9A against 1 Xtreme Power model.
Answered on AEC vs Xtreme Power
Which makers are compared?
APC, Vertiv, Eaton, Xtreme Power, Delta, Toshiba: 28 current models, with 8 AEC INFINITE models.
Answered on Large 480 V UPS
How many UPS models does the AEC cross reference cover?
1,410 models of 28 brands on 120 V, 208/240 V, 208 V and 480 V supplies, each crossed to the AEC UPS of the same supply and at least the same kVA and kW. The ratings and supplies come from each maker's published listings, checked in October 2026.
Answered on Cross reference
What replaces the APC SRT3000RMXLA?
The AEC LUMINA LUM3000RT-2U-LI, lithium inside, for the 3 kVA / 2.7 kW APC SRT3000RMXLA on 120 V single-phase. With lead-acid (VRLA) batteries instead: the AEC FERRUS RT FER3000RT-6X9.
Answered on Cross reference
What replaces the Vertiv GXT5-3000LVRT2UXL?
The AEC LUMINA LUM3000RT-2U-LI, lithium inside, for the 3 kVA / 2.7 kW Vertiv GXT5-3000LVRT2UXL on 120 V single-phase. With lead-acid (VRLA) batteries instead: the AEC FERRUS RT FER3000RT-6X9.
Answered on Cross reference
Is the AEC model a drop-in replacement?
Not always: it takes the same load on the same supply, but it is a starting point, not an equal: runtime, outlets, size and options differ, so check both datasheets, the plugs and the rack before you order. Send us the label and the load and we confirm the match.
Answered on Cross reference
Can an L6 module be replaced with the load on?
Yes: each module reaches the UPS through its own isolated DC/DC converter, so one is slid out and a new one slid in with the load on, in about 5 minutes. New modules work beside old ones.
Answered on Lithium batteries
Which listings and tests does the L6 hold?
The AEC L6 lithium catalog (2026) gives the modules as UL 1973 listed, and UL 9540A and UN38.3 tested.
Answered on Lithium batteries
Which AEC UPS run on L6 cabinets?
INFINITE (100 to 600 kVA) and INFINITE 1.5MW (750 to 1,500 kVA) run on external L6 cabinets, or on a lead-acid bank. ETHERNO takes the same 50 Ah modules inside its tower, up to three.
Answered on Lithium batteries
What is a split-phase UPS?
A UPS whose input and output are 120/240 V split phase: two 120 V legs 180 degrees apart and a neutral. Loads connect at 240 V between the legs or at 120 V from a leg to the neutral.
Answered on 120/240V split-phase UPS
240 V or 208 V: what is the difference?
240 V comes from a split-phase service; 208 V is measured between two legs of a three-phase 208Y/120 V service. Check the equipment's nameplate: some equipment accepts both, some only one. For a three-phase 208 V panel, see the 208V three-phase UPS.
Answered on 120/240V split-phase UPS
Can a split-phase UPS run a motor or a well pump?
Yes, if the UPS is sized for the starting current: motors draw several times their running current when they start, so size for that, not for the running watts: send us the motor's nameplate and our engineers size it.
Answered on 120/240V split-phase UPS
How many amps does a 30 kVA UPS draw at 208 V?
About 83 A per phase at full load: 30,000 VA ÷ (√3 × 208 V). The breakers follow the UPS's own input current at full charge, in its datasheet.
Answered on 208V three-phase UPS
What is a three-phase UPS?
A UPS that takes and delivers three-phase power: three lines 120 degrees apart, at 208 V or 480 V in the United States. It carries larger loads than a single-phase UPS with less current per conductor, which is why server rooms, data centers, hospitals and factories use it.
Answered on Three-phase UPS
Single-phase or three-phase UPS?
Single-phase for loads up to about 20 kVA on 120 V or 120/240 V circuits; three-phase when the panel is three-phase or the load is larger. AEC three-phase UPS start at 10 kVA.
Answered on Three-phase UPS
How many amps does a three-phase UPS draw?
Current per phase = kVA × 1,000 ÷ (√3 × voltage): a 30 kVA UPS carries about 83 A per phase at 208 V and 36 A at 480 V, at full load and unity power factor.
Answered on Three-phase UPS
Runtime and batteries 12 questions
Where do the figures come from?
Rival figures from each maker's own published documents, read 10 Oct 2026; each document is named, model by model, under Sources. AEC figures from the AEC 2026 catalog and AEC's runtime tables; a model without a runtime table of its own reads not published. Where a maker's documents disagree, the more conservative figure is used.
Answered on Large 480 V UPS
Which battery cabinets and packs fit the FERRUS?
BAT0424, 31.4 lb; BAT0848, 58.8 lb; BAT1272, 86.2 lb, from the AEC 2026 catalog. AEC sizes the number of cabinets for the load and the minutes.
Answered on VRLA batteries and cabinets
Which battery cabinets and packs fit the FERRUS RT?
BAT0424RT, 35.4 lb; BAT0848RT, 64.8 lb; BAT1272RT, 94.2 lb, from the AEC 2026 catalog. AEC sizes the number of cabinets for the load and the minutes.
Answered on VRLA batteries and cabinets
Which battery cabinets and packs fit the FERRUS SP?
BB4US, 110 lb, from the AEC 2026 catalog. AEC sizes the number of cabinets for the load and the minutes.
Answered on VRLA batteries and cabinets
Which battery cabinets and packs fit the FERRUS SP RT?
BAT16192RT, 123.6 lb, from the AEC 2026 catalog. AEC sizes the number of cabinets for the load and the minutes.
Answered on VRLA batteries and cabinets
Which battery cabinets and packs fit the RADIANT-IB?
RADIB-BATTR-EMPTY, 5 lb; RADIB-BATTR-10x9A, 63.5 lb, from the AEC 2026 catalog. AEC sizes the number of cabinets for the load and the minutes.
Answered on VRLA batteries and cabinets
Which battery cabinets and packs fit the CIRRO-IB?
CIRIB-BATTR-10x9A, 63.5 lb; CIRIB-BATTR-EMPTY, 5 lb, from the AEC 2026 catalog. AEC sizes the number of cabinets for the load and the minutes.
Answered on VRLA batteries and cabinets
How long does a VRLA battery last in a UPS?
AEC's AGM blocks have a design life of 10–12 years at 77 °F (25 °C). A common rule of thumb for VRLA: life halves for about every 14 °F (8 °C) above 77 °F, so the battery room's temperature matters as much as the block.
Answered on VRLA batteries and cabinets
How long does the containerized UPS run on battery?
15 minutes at full load: one L6 lithium cabinet of 58 kWh per 200 kW, 348 kWh at 1.2 MW with six cabinets.
Answered on Containerized UPS
How long does one L6 cabinet run a UPS?
About 15 minutes at 200 kW from one cabinet of 20 modules of 50 Ah: each module is rated 10 kW for 15 minutes, 2.88 kWh nominal. Runtime grows module by module, and up to 15 cabinets run in one system.
Answered on Lithium batteries
How large can a 480 V AEC UPS go?
One CIRRO frame carries up to 1,600 kVA (16 power modules of 100 kVA); INFINITE reaches 600 kVA with three 200 kVA frames, and one INFINITE 1.5MW frame 1,500 kVA, up to eight in parallel. Our engineers size the frames, the modules and the batteries for the load and the minutes.
Answered on 480V three-phase UPS
Are the batteries covered?
Yes: VRLA batteries have 2 years. Lithium batteries are covered with the UPS: 5 years on LUMINA and ETHERNO, and 5 years on the L6 lithium cabinets for INFINITE, batteries included.
Answered on Warranty
Lithium batteries 11 questions
Is AEC UPS reliable?
Yes, on what can be checked: ETHERNO and AUREON hold a UL certificate of compliance to UL 1778 issued to AEC UPS USA LLC (UL file E543003). INFINITE 1.5MW is UL 1778 listed under the same UL file; LUMINA is ETL Listed to UL 1778 and CSA C22.2 No. 107.3; the group's quality management system is certified to ISO 9001:2015 (SGS, valid to June 2027); every AEC UPS has 3 years of warranty from start-up, LUMINA and ETHERNO 5 years with their lithium batteries; and Allis Electric publishes its accounts as a listed company in Taipei.
Answered on About AEC
Is AEC a good alternative to APC?
Yes, in the 7 size classes on this page, where 25 APC models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 10.5 min for the APC SRT1000RMXLA (VRLA); runtime, half load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 27 min against 25.4 min for the APC SRT1000RMXLA (VRLA); runtime, full load at 10 kVA, the AEC ETH10-1X50A-LI (lithium) with 14 min against 10.5 min for the APC GVSUPS10KB4FS (VRLA). Where APC's leads: depth at 1.5 kVA against AEC LUMINA, the APC SMT1500RM2UC with 18.8 in (478 mm); runtime, full load at 10 kVA against AEC AUREON, the APC GVSUPS10KB4FS (VRLA) with 10.5 min. The cards above each table give every column, size by size.
Answered on AEC vs APC
Is AEC a good alternative to CyberPower?
Yes, in the 1 size class on this page, where 2 CyberPower models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1.5 kVA, the AEC LUM1500RT-2U-LI (lithium) with 11 min against 4 min for the CyberPower OL1500RTXL2U (VRLA); runtime, half load at 1.5 kVA, the AEC LUM1500RT-2U-LI (lithium) with 27 min (AEC runtime table) against 12.5 min for the CyberPower OL1500RTXL2U (VRLA). Where CyberPower's leads: depth at 1.5 kVA against AEC LUMINA, the CyberPower OL1500RTXL2U with 16.9 in (429 mm). The cards above each table give every column, size by size.
Answered on AEC vs CyberPower
Is AEC a good alternative to Delta?
Yes, in the 7 size classes on this page, where 17 Delta models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 4 min for the Delta RT-1K; runtime, half load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 27 min against 10 min for the Delta RT-1K; footprint W × D at 20 kVA, the AEC ETH20-2X50A-LI (lithium) with 12.6 × 39.1 in (320 × 993 mm) against 20.5 × 31.5 in (520 × 800 mm) for the Delta HPH-20K-LV-B (VRLA). Where Delta's leads: depth at 1 kVA against AEC LUMINA, the Delta RX-1K with 12.2 in (310 mm); efficiency, online at 40 to 60 kVA against AEC RADIANT, the Delta DPH-60K-LV with 95 %. The cards above each table give every column, size by size.
Answered on AEC vs Delta
Is AEC a good alternative to Eaton?
Yes, in the 7 size classes on this page, where 19 Eaton models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 6.3 min for the Eaton 9PX1000RT (VRLA); runtime, half load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 27 min against 18 min for the Eaton 9PX1000RT (VRLA); runtime, full load at 10 kVA, the AEC ETH10-1X50A-LI (lithium) with 14 min against 8 min for the Eaton 9355 10 kVA 208 V (VRLA). Where Eaton's leads: depth at 1.5 kVA against AEC LUMINA, the Eaton 5PX1500RTG2 with 17.6 in (447 mm); footprint W × D at 10 kVA against AEC ETHERNO, the Eaton 9355 10 kVA 208 V (VRLA) with 12 × 33.5 in (305 × 851 mm). The cards above each table give every column, size by size.
Answered on AEC vs Eaton
Is AEC a good alternative to Toshiba?
Yes, in the 6 size classes on this page, where 16 Toshiba models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 5 min for the Toshiba T1S0A1000AXAR2 (VRLA); efficiency, online at 1 kVA, the AEC LUM1000RT-2U-LI with 91.7 % against 86 % for the Toshiba T1S0A1000AXAR2; efficiency, online at 20 kVA, the AEC ETH20-2X50A-LI with 94 % against 92.9 % for the Toshiba 11A0H020KCXC. Where Toshiba's leads: depth at 1.5 kVA against AEC LUMINA, the Toshiba T1S0A1500AXAR2 with 19.7 in (500 mm); efficiency, online at 90 to 150 kVA against AEC CIRRO-IB, the Toshiba T90S3S10KS6XSN2 with 96.6 %. The cards above each table give every column, size by size.
Answered on AEC vs Toshiba
Is AEC a good alternative to Tripp Lite?
Yes, in the 1 size class on this page, where 2 Tripp Lite models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1.5 kVA, the AEC LUM1500RT-2U-LI (lithium) with 11 min against 5.8 min for the Tripp Lite SU1500RTXLCD2U (VRLA); runtime, half load at 1.5 kVA, the AEC LUM1500RT-2U-LI (lithium) with 27 min (AEC runtime table) against 16.5 min for the Tripp Lite SU1500RTXLCD2U (VRLA). Where Tripp Lite's leads: depth at 1.5 kVA against AEC LUMINA, the Tripp Lite SU1500RTXLCD2U with 17.7 in (450 mm). The cards above each table give every column, size by size.
Answered on AEC vs Tripp Lite
Is AEC a good alternative to Vertiv?
Yes, in the 7 size classes on this page, where 31 Vertiv models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 6.7 min for the Vertiv GXT5-1000LVRT2UXL (VRLA); runtime, half load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 27 min against 17.9 min for the Vertiv GXT5-1000LVRT2UXL (VRLA); runtime, full load at 10 kVA, the AEC ETH10-1X50A-LI (lithium) with 14 min against 6 min for the Vertiv EXS10KN (VRLA). Where Vertiv's leads: efficiency, online at 1 kVA against AEC LUMINA, the Vertiv GXT5-1000LVRT2UXL with 95 %; efficiency, online at 10 kVA against AEC ETHERNO, the Vertiv EXS10KN with 96.2 %. The cards above each table give every column, size by size.
Answered on AEC vs Vertiv
Is AEC a good alternative to Xtreme Power?
Yes, in the 7 size classes on this page, where 30 Xtreme Power models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 8 min for the Xtreme Power P91c-1000 (VRLA); runtime, half load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 27 min against 20 min for the Xtreme Power P91c-1000 (VRLA); efficiency, online at 15 to 30 kVA, the AEC RAD90-1X15 with 94 % against 93 % for the Xtreme Power M90C-6S24K. Where Xtreme Power's leads: efficiency, online at 1 kVA against AEC LUMINA, the Xtreme Power P91c-1000 with 94 %; runtime, full load at 10 kVA against AEC ETHERNO, the Xtreme Power Li90-10K (lithium) with 15 min. The cards above each table give every column, size by size.
Answered on AEC vs Xtreme Power
How long does an L6 lithium battery last?
The AEC L6 lithium catalog (2026) gives a 15-year life and 5,000+ cycles; the cabinets carry a 5-year warranty with their batteries.
Answered on Lithium batteries
Lithium or VRLA for a 120 V UPS?
Lithium (LUMINA) weighs less, lasts longer and gives more minutes in the same 2U; VRLA (FERRUS, FERRUS RT) costs less up front. From the catalog: LUMINA 1 kVA runs 11 minutes at full load and 27 at half load; FERRUS RT 1 kVA runs 4.2 minutes at full load, and up to 66 minutes with four battery packs by AEC's estimate.
Answered on 120V single-phase UPS
Installation, size and connections 22 questions
Which Large 480 V UPS has the best UPS weight per kW at 200 to 600 kW?
In this comparison, the AEC INF-200: 2.96 lb (1.34 kg), against 3.43 lb (1.56 kg) for the APC GVL500KDS, the lowest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on Large 480 V UPS
Which Modular three-phase UPS, 208 V has the best footprint W × D at 75 to 100 kVA?
In this comparison, the AEC RADIB100-5X20: 23.6 × 39.3 in (599 × 998 mm), against 47.2 × 42.1 in (1,199 × 1,069 mm) for the APC SY90K100F, the lowest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on Modular three-phase UPS, 208 V
Which Modular 480 V UPS up to 1,600 kVA has the best UPS weight per kW at 100 to 400 kVA?
In this comparison, the AEC CIR360-6X60: 3.02 lb (1.37 kg), against 5.33 lb (2.42 kg) for the Toshiba T90S3S22KS6XSN2, the lowest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on Modular 480 V UPS up to 1,600 kVA
Which Modular 480 V UPS up to 1,600 kVA has the best UPS weight per kW at 500 to 800 kVA?
In this comparison, the AEC CIR800-8X100: 2.38 lb (1.08 kg), against 3.43 lb (1.56 kg) for the APC GVL500KDS, the lowest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on Modular 480 V UPS up to 1,600 kVA
Which Modular 480 V UPS up to 1,600 kVA has the best UPS weight per kW at 1,000 to 1,600 kVA?
In this comparison, the AEC CIR1200-12X100: 2.18 lb (0.99 kg), against 2.91 lb (1.32 kg) for the Eaton 9395XC-1500/1500, the lowest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on Modular 480 V UPS up to 1,600 kVA
Which 1–3 kVA rack UPS, 120 V has the best runtime, full load at 1 kVA?
In this comparison, the AEC LUM1000RT-2U-LI: 11 min, against 10.5 min for the APC SRT1000RMXLA, the highest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on 1–3 kVA rack UPS, 120 V
Which 1–3 kVA rack UPS, 120 V has the best runtime, half load at 1 kVA?
In this comparison, the AEC LUM1000RT-2U-LI: 27 min, against 25.4 min for the APC SRT1000RMXLA, the highest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on 1–3 kVA rack UPS, 120 V
Which 1–3 kVA rack UPS, 120 V has the best weight at 1 kVA?
In this comparison, the AEC LUM1000RT-2U-LI: 20 lb (9 kg), against 26 lb (12 kg) for the Xtreme Power P91-1000, the lowest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on 1–3 kVA rack UPS, 120 V
What supply does the AEC containerized UPS need?
480 V, 60 Hz three-phase, 3 wires and ground, in and out, by the AEC containerized UPS catalog (2026). The INFINITE UPS inside is 3-wire, without a neutral: loads that need 277 V line to neutral go behind a transformer.
Answered on Containerized UPS
How much does the containerized UPS weigh?
The catalog gives 16,980 lb (7,702 kg) of UPS and battery at 1 MW and 19,390 lb (8,795 kg) at 1.2 MW, in a 40 ft container. Ask AEC for the container's own weight and the pad drawing of your project.
Answered on Containerized UPS
How is the container cooled and protected?
Four in-row A/C units with four outdoor units, a cold aisle in front of the cabinets and a hot aisle behind them. Fire, water, humidity and temperature are watched, every L6 cabinet has a smoke detector and fire protection, and entry is by fingerprint, with CCTV inside and out.
Answered on Containerized UPS
What size UPS do I need for a small server rack?
Add up the watts of everything on the UPS, then choose a model whose kW rating is at least 20 to 25 % higher, so it is not running at its limit. The UPS sizing tool does it from your load and the minutes you need.
Answered on 120V single-phase UPS
Rack or tower?
LUMINA is rack-mount (2U); FERRUS is a tower; FERRUS RT goes either way. Choose by where it lives: a 19-inch rack, or the floor next to the equipment.
Answered on 120V single-phase UPS
What is a 208V UPS?
A three-phase UPS for 208Y/120 V supplies: 208 V between any two lines, 120 V from a line to the neutral. It carries server rooms, small data centers and critical building loads.
Answered on 208V three-phase UPS
Tower or modular?
A tower (ETHERNO, AUREON) is one unit of fixed size. A modular UPS (RADIANT, RADIANT-IB) holds power modules in a frame: it grows by adding modules and stays on line while one is swapped (N+1).
Answered on 208V three-phase UPS
3-wire or 4-wire 480 V UPS?
Match the supply. A 4-wire supply carries the neutral: CIRRO and CIRRO-IB. A 3-wire (delta) supply has none: INFINITE or INFINITE 1.5MW. Loads that need 277 V line-to-neutral go on a 4-wire UPS.
Answered on 480V three-phase UPS
208 V or 480 V?
208 V (208Y/120 V) suits server rooms and buildings that distribute at 208 V; 480 V suits large loads and data centers, with less than half the current for the same power. The UPS follows the panel it is connected to.
Answered on Three-phase UPS
What is the difference between 480 V 3-wire and 4-wire?
A 4-wire supply carries the neutral, a 3-wire (delta) supply does not. CIRRO is built for 480 V 4-wire, INFINITE for 480 V 3-wire: pick the UPS by the supply on site.
Answered on Three-phase UPS
Modular or tower?
A tower UPS is one unit of fixed size; a modular UPS holds power modules in a frame, so it grows by adding modules and stays on line when one is swapped (N+1). AEC offers both.
Answered on Three-phase UPS
How much working space does a UPS need in front?
3 ft in front of equipment up to 150 V to ground, under NEC 110.26(A)(1). From 151 to 600 V, 3 ft with nothing grounded opposite, 3.5 ft facing a grounded wall, 4 ft facing other live equipment. At least 30 in wide or the width of the equipment, and 6.5 ft high. Room fit draws it and checks it.
Answered on Room fit
How high can the UPS breakers be?
NEC 240.24(A): the center of the handle in its highest position no more than 6 ft 7 in above the floor. Room fit marks that line on the front view and checks every breaker it knows the height of.
Answered on Room fit
Does Room fit check the way in?
Yes: every door, corridor and elevator between the truck and the room, against the cabinet's size and weight as it travels.
Answered on Room fit
Communication and monitoring 14 questions
What does a site need?
The UPS, an AEC SNMP card in it and an internet connection on site. Nothing else: no server and no software to install.
Answered on UPS Monitoring Cloud
How do alarms arrive?
By email, the moment something happens: a mains failure, a battery alarm, a fault.
Answered on UPS Monitoring Cloud
Can the card also talk to our own systems?
Yes. The SNMP cards work over SNMP and Modbus TCP/IP, for remote monitoring, alarm notification and shutdown management over the network; a dry contact relay card fits every series.
Answered on UPS Monitoring Cloud
What is a dry contact card on a UPS?
A card of potential-free relays: each relay opens or closes when the UPS enters a state, such as a mains failure, a low battery, a fault or bypass. A building management system, an alarm panel or a PLC reads the contacts without any network or protocol.
Answered on Dry contact card
Which AEC UPS takes the dry contact card?
Every AEC series: it goes into the UPS's intelligent slot, according to the AEC accessories catalog (2026), which gives the slots of each series in the table above.
Answered on Dry contact card
What signals does the dry contact card give?
Mains failure, battery low, UPS fault and bypass, as potential-free relays, by the AEC accessories catalog (2026). The relay rating and the pin-out of the card are not published on this site: ask AEC for them with your project.
Answered on Dry contact card
Dry contacts or SNMP?
Dry contacts give a few on/off signals to wired systems; the SNMP card gives every measurement and alarm over the network. Many sites use both: dry contacts to the building system, SNMP to IT.
Answered on Dry contact card
What is an SNMP card for a UPS?
A network card that goes into the UPS's communication slot and gives the UPS an IP address. Monitoring software, a network management system or a web browser can then read its status, measurements and alarms, receive SNMP traps when something changes, and shut servers down before the battery runs out.
Answered on SNMP card
Which SNMP card fits my AEC UPS?
SNMP-L fits LUMINA, ETHERNO, AUREON, INFINITE, INFINITE 1.5MW; SNMP-M fits FERRUS, FERRUS RT, FERRUS SP, FERRUS SP RT, RADIANT, RADIANT-IB, CIRRO-IB, CIRRO. The two are not interchangeable: each speaks its own series' protocol.
Answered on SNMP card
Do the cards support SNMPv3?
Yes. Both cards support SNMP v1, v2c and v3 (user names with authentication and encryption), as their user manuals describe.
Answered on SNMP card
Does the card work with my network management system?
Yes, if it reads the standard UPS MIB: the cards answer on RFC 1628, which most network management systems read, and send traps to the receivers you set (port 162). Polling uses the standard SNMP port 161.
Answered on SNMP card
Can the UPS shut down my servers?
Yes. AEC's shutdown program (SNMP-L) runs on each server and closes it safely during a long outage, before the battery runs out; the card also sends the alarm by email and trap.
Answered on SNMP card
SNMP or USB: which one do I need?
USB (or RS-232) connects one computer directly to one UPS, usually for a single server's shutdown. The SNMP card puts the UPS on the network, so many computers and the monitoring system can read it at once, from anywhere.
Answered on SNMP card
Is Modbus available?
Yes: the catalog lists both cards for Modbus TCP/IP remote monitoring, and ETHERNO and CIRRO also have Modbus or RS-485 and dry contacts as standard ports.
Answered on SNMP card
Efficiency and operation 2 questions
How do I get it?
Ask us with the contact form: we tell you the card for each UPS and put your sites online.
Answered on UPS Monitoring Cloud
Which Modular three-phase UPS, 208 V has the best efficiency, online at 15 to 30 kVA?
In this comparison, the AEC RAD90-1X15: 94 %, against 93 % for the Xtreme Power M90C-6S24K, the highest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on Modular three-phase UPS, 208 V
Warranty, service and maintenance 9 questions
What is AEC UPS?
AEC UPS is the UPS brand of the AEC Group, whose parent company, Allis Electric Co., Ltd., has worked in power equipment since 1968 and has been listed on the Taiwan Stock Exchange since 1994 (TWSE 1514). In the United States and Latin America, AEC UPS USA LLC in Miami sells, stocks and services online UPS from 1 kVA to 1.6 MW.
Answered on About AEC
How do I become an AEC partner or dealer?
Apply on the AEC partner page: dealers, integrators, installers and consulting engineers who sell, specify or service AEC UPS send their company, what they sell or specify, and where, and an AEC engineer calls within one business day.
Answered on About AEC
Is it included with the UPS?
No: it is a new, optional service from AEC, set up on request. Ask us with the contact form and we tell you what your sites need.
Answered on UPS Monitoring Cloud
How do I get an account?
AEC opens it when it sets up the service. The site owner then signs in and sees every UPS of every site online.
Answered on UPS Monitoring Cloud
Which Modular three-phase UPS, 208 V has the best warranty, UPS / battery at 40 to 60 kVA?
In this comparison, the AEC RAD90-3X15: 3 years on UPS · 2 years on VRLA batteries, against 2 yr / 2 yr for the Xtreme Power M90U-60, the highest figure among the other makers' models here. Figures from each maker's published documents, read 10 Oct 2026.
Answered on Modular three-phase UPS, 208 V
How long is the warranty on an AEC UPS?
3 years from start-up on every AEC UPS. LUMINA and ETHERNO have 5 years, their lithium batteries included, and an INFINITE registered with its serial number and invoice gets 5 years.
Answered on Warranty
When does the warranty start?
On the day of the start-up, and no later than 6 months after the UPS leaves AEC. With no start-up date on record, it runs from AEC's invoice. Three-phase systems need the start-up by AEC or a technician AEC authorizes.
Answered on Warranty
Do I need to register my UPS?
Yes for an INFINITE: registering it with the serial number and the invoice takes its warranty from 3 to 5 years. For every other AEC UPS it puts the UPS on record with AEC and confirms its dates.
Answered on Warranty
How do I make a warranty claim?
Request service with the serial number, the invoice and what the display shows. Support answers 24/7 by phone and WhatsApp and tries to solve it remotely first; if the unit must come back, AEC gives an RMA number and the unit goes to the AEC warehouse in Doral, Florida, which ships it back repaired or replaced.
Answered on Warranty
About the product and AEC 9 questions
Where do the APC figures come from?
From APC's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two APC documents disagree, the more conservative figure is used.
Answered on AEC vs APC
Where do the CyberPower figures come from?
From CyberPower's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two CyberPower documents disagree, the more conservative figure is used.
Answered on AEC vs CyberPower
Where do the Delta figures come from?
From Delta's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two Delta documents disagree, the more conservative figure is used.
Answered on AEC vs Delta
Where do the Eaton figures come from?
From Eaton's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two Eaton documents disagree, the more conservative figure is used.
Answered on AEC vs Eaton
Where do the Toshiba figures come from?
From Toshiba's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two Toshiba documents disagree, the more conservative figure is used.
Answered on AEC vs Toshiba
Where do the Tripp Lite figures come from?
From Tripp Lite's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two Tripp Lite documents disagree, the more conservative figure is used.
Answered on AEC vs Tripp Lite
Where do the Vertiv figures come from?
From Vertiv's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two Vertiv documents disagree, the more conservative figure is used.
Answered on AEC vs Vertiv
Where do the Xtreme Power figures come from?
From Xtreme Power's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two Xtreme Power documents disagree, the more conservative figure is used.
Answered on AEC vs Xtreme Power
Can I get the layout as a PDF or for CAD?
Yes, with the project: ask AEC and an engineer sends the PDF layout and the plan for CAD.
Answered on Room fit
By series
Still a question?
Tell us the load, the voltage and the minutes you need: an AEC engineer answers.