AEC vs APC
AEC against APC, model by model.
The AEC alternative to APC, size class by size class: AEC LUMINA for the Smart-UPS On-Line SRT; AEC ETHERNO for the Galaxy VS 208 V; AEC AUREON for the Galaxy VS 208 V; AEC RADIANT for the Galaxy VS 208 V; AEC CIRRO-IB for the Galaxy VS 480 V; AEC INFINITE for the Galaxy VL; AEC CIRRO for the Galaxy VS 480 V.
1–3 kVA rack UPS, 120 V
AEC LUMINA vs APC.
1 kVA
- Runtime, full load11 minLUM1000RT-2U-LI, lithium · best rival 10.5 min, APC, VRLA
- Runtime, half load27 minLUM1000RT-2U-LI, lithium · best rival 25.4 min, APC, VRLA
- Depth16.5 in (420 mm)LUM1000RT-2U-LI · best rival 20 in (508 mm), APC
- Weight20 lb (9 kg)LUM1000RT-2U-LI, lithium · best rival 49 lb (22 kg), APC, VRLA
- Warranty, UPS / battery5 years incl. lithium batteriesLUM1000RT-2U-LI · best rival 3 yr / 2 yr, APC
1.5 kVA
- Runtime, full load11 minLUM1500RT-2U-LI, lithium · best rival 4.6 min, APC, VRLA
- Runtime, half load27 min (AEC runtime table)LUM1500RT-2U-LI, lithium · best rival 26 min, APC, VRLA
- Efficiency, online92.5 %LUM1500RT-2U-LI · best rival 91.5 %, APC
- Weight32 lb (15 kg)LUM1500RT-2U-LI, lithium · best rival 49 lb (22 kg), APC, VRLA
- Warranty, UPS / battery5 years incl. lithium batteriesLUM1500RT-2U-LI · best rival 3 yr / 2 yr, APC
- DepthAPC: 18.8 in (478 mm)
2 to 2.2 kVA
- Runtime, full load23 minLUM2200RT-2U-LI, lithium · best rival 3.2 min, APC, VRLA
- Runtime, half load46 minLUM2200RT-2U-LI, lithium · best rival 10.3 min, APC, VRLA
- Efficiency, online92.5 %LUM2000RT-2U-LI · best rival 91.5 %, APC
- Depth22.4 in (570 mm)LUM2000RT-2U-LI · best rival 23 in (584 mm), APC
- Weight30 lb (14 kg)LUM2000RT-2U-LI, lithium · best rival 58 lb (26 kg), APC, VRLA
- Warranty, UPS / battery5 years incl. lithium batteriesLUM2000RT-2U-LI · best rival 3 yr / 2 yr, APC
3 kVA
- Runtime, full load11 minLUM3000RT-2U-LI, lithium · best rival 4 min, APC, lithium
- Runtime, half load27 minLUM3000RT-2U-LI, lithium · best rival 10.4 min, APC, VRLA
- Efficiency, online92.5 %LUM3000RT-2U-LI · best rival 91.5 %, APC
- Rack unitsAPC: 1U
- WeightAPC: 35 lb (16 kg), lithium
1 kVA
| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|---|---|
| LUM1000RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 900 W | 11 min | 27 min | 91.7 % | 2U | 16.5 in (420 mm) | 20 lb (9 kg) | 5 years incl. lithium batteries |
| APC1 model at this size | Online | VRLA, inside | 900 W | 10.5 min | 25.4 min | 91.5 % | 2U | 20 in (508 mm) | 49 lb (22 kg) | 3 yr / 2 yr |
1.5 kVA
| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|---|---|
| LUM1500RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 1,350 W | 11 min | 27 min (AEC runtime table) | 92.5 % | 2U | 22.6 in (574 mm) | 32 lb (15 kg) | 5 years incl. lithium batteries |
| APC2 models at this size | Line-interactive / Online | VRLA, inside | 1,000 W / 1,350 W | 4.6 min (Smart-UPS On-Line SRT) | 13.2 min – 26 min | 91.5 % (Smart-UPS On-Line SRT) | 2U | 18.8 in (478 mm) – 20 in (508 mm) | 49 lb (22 kg) – 58 lb (26 kg) | 3 yr / 2 yr |
2 to 2.2 kVA
| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|---|---|
| LUM2000RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 1,800 W | 11 min | 27 min | 92.5 % | 2U | 22.4 in (570 mm) | 30 lb (14 kg) | 5 years incl. lithium batteries |
| LUM2200RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 1,980 W | 23 min | 46 min | 92.6 % | 2U | 24.2 in (615 mm) | 42 lb (19 kg) | 5 years incl. lithium batteries |
| APC1 model at this size | Online | VRLA, inside | 1,800 W | 3.2 min | 10.3 min | 91.5 % | 2U | 23 in (584 mm) | 58 lb (26 kg) | 3 yr / 2 yr |
3 kVA
| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|---|---|
| LUM3000RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 2,700 W | 11 min | 27 min | 92.5 % | 2U | 22.4 in (570 mm) | 38 lb (17 kg) | 5 years incl. lithium batteries |
| APC3 models at this size | Line-interactive / Online | VRLA, inside / Lithium, inside | 2,700 W / 2,850 W | 3 min – 4 min | 10 min (Smart-UPS Ultra); 10.4 min (Smart-UPS On-Line SRT) | 91.5 % (Smart-UPS On-Line SRT) | 1U – 2U | 22.1 in (560 mm) – 26.9 in (683 mm) | 35 lb (16 kg) – 98 lb (44 kg) | 3 yr / 2 yr – 5 yr / 5 yr |
10–30 kVA three-phase UPS, 208 V
AEC ETHERNO vs APC.
10 kVA
- Runtime, full load14 minETH10-1X50A-LI, lithium · best rival 10.5 min, APC, VRLA
- Footprint W × D12.6 × 39.1 in (320 × 993 mm)ETH10-1X50A-LI, lithium · best rival 20.5 × 33.4 in (521 × 847 mm), APC, VRLA
- Weight298 lb (135 kg)ETH10-1X50A-LI, lithium · best rival 705 lb (320 kg), APC, VRLA
20 kVA
- Runtime, full load14 minETH20-2X50A-LI, lithium · best rival 10.5 min, APC, VRLA
- Footprint W × D12.6 × 39.1 in (320 × 993 mm)ETH20-2X50A-LI, lithium · best rival 20.5 × 33.4 in (521 × 847 mm), APC, VRLA
- Weight390 lb (177 kg)ETH20-2X50A-LI, lithium · best rival 1,014 lb (460 kg), APC, VRLA
30 kVA
- Runtime, full load14 minETH30-3X50A-LI, lithium · best rival 10.5 min, APC, VRLA
- Footprint W × D12.6 × 39.1 in (320 × 993 mm)ETH30-3X50A-LI, lithium · best rival 21.7 × 33.4 in (550 × 847 mm), APC, VRLA
- Weight485 lb (220 kg)ETH30-3X50A-LI, lithium · best rival 1,466 lb (665 kg), APC, VRLA
10 kVA
| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|
| ETH10-1X50A-LIAEC ETHERNODatasheet · Size it for your load | 10 kW | Lithium, 1 × 50 Ah module, inside | 14 min | 27 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 298 lb (135 kg) | 5 years |
| ETH10-2X50A-LIAEC ETHERNODatasheet · Size it for your load | 10 kW | Lithium, 2 × 50 Ah modules, inside | 27 min | 55 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 379 lb (172 kg) | 5 years |
| ETH10-3X50A-LIAEC ETHERNODatasheet · Size it for your load | 10 kW | Lithium, 3 × 50 Ah modules, inside | 41 min | 82 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 461 lb (209 kg) | 5 years |
| APC2 models at this size | 10 kW | VRLA, inside / VRLA, sold separately | 10.5 min (Galaxy VS 208 V) | — | 92.2 % – 93.7 % | 20.5 × 33.4 in (521 × 847 mm) (Galaxy VS 208 V); 15 × 37.8 in (381 × 960 mm) (Easy UPS 3S) | 705 lb (320 kg) (Galaxy VS 208 V); 265 lb (120 kg) (UPS only) (Easy UPS 3S) | 1 yr / not stated |
20 kVA
| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|
| ETH20-2X50A-LIAEC ETHERNODatasheet · Size it for your load | 20 kW | Lithium, 2 × 50 Ah modules, inside | 14 min | 27 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 390 lb (177 kg) | 5 years |
| ETH20-3X50A-LIAEC ETHERNODatasheet · Size it for your load | 20 kW | Lithium, 3 × 50 Ah modules, inside | 20 min | 41 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 472 lb (214 kg) | 5 years |
| APC2 models at this size | 20 kW | VRLA, inside / VRLA, sold separately | 10.5 min (Galaxy VS 208 V) | — | 93.3 % – 94.3 % | 20.5 × 33.4 in (521 × 847 mm) (Galaxy VS 208 V); 15 × 37.8 in (381 × 960 mm) (Easy UPS 3S) | 1,014 lb (460 kg) (Galaxy VS 208 V); 291 lb (132 kg) (UPS only) (Easy UPS 3S) | 1 yr / not stated |
30 kVA
| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|
| ETH30-3X50A-LIAEC ETHERNODatasheet · Size it for your load | 30 kW | Lithium, 3 × 50 Ah modules, inside | 14 min | 27 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 485 lb (220 kg) | 5 years |
| APC2 models at this size | 30 kW | VRLA, inside / VRLA, sold separately | 10.5 min (Galaxy VS 208 V) | — | 93 % – 94 % | 21.7 × 33.4 in (550 × 847 mm) (Galaxy VS 208 V); 15 × 41.3 in (381 × 1,049 mm) (Easy UPS 3S) | 1,466 lb (665 kg) (Galaxy VS 208 V); 342 lb (155 kg) (UPS only) (Easy UPS 3S) | 1 yr / not stated |
10–30 kVA lead-acid three-phase UPS, 208 V
AEC AUREON vs APC.
10 kVA
- Runtime, full loadAPC: 10.5 min, VRLA
20 kVA
- Runtime, full loadAPC: 10.5 min, VRLA
30 kVA
- Runtime, full loadAPC: 10.5 min, VRLA
10 kVA
| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|
| AUR10-40X9AAEC AUREONDatasheet · Size it for your load | 10 kW | VRLA, 40 × 12 V 9 Ah blocks, inside | 7 min | 25 min | 94 % | 14.9 × 39.1 in (378 × 993 mm) | 465 lb (211 kg) | 3 years on UPS · 2 years on VRLA batteries |
| AUR10-80X9AAEC AUREONDatasheet · Size it for your load | 10 kW | VRLA, 80 × 12 V 9 Ah blocks, inside | 20 min | 60 min | 94 % | 14.9 × 39.1 in (378 × 993 mm) | 699 lb (317 kg) | 3 years on UPS · 2 years on VRLA batteries |
| APC2 models at this size | 10 kW | VRLA, inside / VRLA, sold separately | 10.5 min (Galaxy VS 208 V) | — | 92.2 % – 93.7 % | 20.5 × 33.4 in (521 × 847 mm) (Galaxy VS 208 V); 15 × 37.8 in (381 × 960 mm) (Easy UPS 3S) | 705 lb (320 kg) (Galaxy VS 208 V); 265 lb (120 kg) (UPS only) (Easy UPS 3S) | 1 yr / not stated |
20 kVA
| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|
| AUR20-60X9AAEC AUREONDatasheet · Size it for your load | 20 kW | VRLA, 60 × 12 V 9 Ah blocks, inside | 4.5 min (AEC runtime table) | 13.5 min (AEC runtime table) | 94 % | 14.9 × 39.1 in (378 × 993 mm) | 609 lb (276 kg) | 3 years on UPS · 2 years on VRLA batteries |
| AUR20-80X9AAEC AUREONDatasheet · Size it for your load | 20 kW | VRLA, 80 × 12 V 9 Ah blocks, inside | 7.5 min (AEC runtime table) | 20 min (AEC runtime table) | 94 % | 14.9 × 39.1 in (378 × 993 mm) | 726 lb (329 kg) | 3 years on UPS · 2 years on VRLA batteries |
| APC2 models at this size | 20 kW | VRLA, inside / VRLA, sold separately | 10.5 min (Galaxy VS 208 V) | — | 93.3 % – 94.3 % | 20.5 × 33.4 in (521 × 847 mm) (Galaxy VS 208 V); 15 × 37.8 in (381 × 960 mm) (Easy UPS 3S) | 1,014 lb (460 kg) (Galaxy VS 208 V); 291 lb (132 kg) (UPS only) (Easy UPS 3S) | 1 yr / not stated |
30 kVA
| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|
| AUR30-80X9AAEC AUREONDatasheet · Size it for your load | 30 kW | VRLA, 80 × 12 V 9 Ah blocks, inside | 4 min | 14 min | 94 % | 14.9 × 39.1 in (378 × 993 mm) | 750 lb (340 kg) | 3 years on UPS · 2 years on VRLA batteries |
| APC2 models at this size | 30 kW | VRLA, inside / VRLA, sold separately | 10.5 min (Galaxy VS 208 V) | — | 93 % – 94 % | 21.7 × 33.4 in (550 × 847 mm) (Galaxy VS 208 V); 15 × 41.3 in (381 × 1,049 mm) (Easy UPS 3S) | 1,466 lb (665 kg) (Galaxy VS 208 V); 342 lb (155 kg) (UPS only) (Easy UPS 3S) | 1 yr / not stated |
Modular three-phase UPS, 208 V
AEC RADIANT vs APC.
40 to 60 kVA
- Efficiency, onlineAPC: 94.8 %
- Footprint W × DAPC: 21.7 × 33.4 in (550 × 847 mm), VRLA
75 to 100 kVA
- Footprint W × D23.6 × 39.3 in (599 × 998 mm)RADIB100-5X20, VRLA · best rival 47.2 × 42.1 in (1,199 × 1,069 mm), APC, VRLA
40 to 60 kVA
| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| RAD90-3X15AEC RADIANTDatasheet · Size it for your load | 45 kW | Modular, 15 kVA modules | VRLA, external bank | 94 % | 17.4 × 33.1 in (442 × 840 mm) | 3 years on UPS · 2 years on VRLA batteries |
| RAD90-4X15AEC RADIANTDatasheet · Size it for your load | 60 kW | Modular, 15 kVA modules | VRLA, external bank | 94 % | 17.4 × 33.1 in (442 × 840 mm) | 3 years on UPS · 2 years on VRLA batteries |
| RADIB100-2X20AEC RADIANT-IBDatasheet · Size it for your load | 40 kW | Modular, 20 kVA modules | VRLA, inside | 94 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| RADIB100-3X20AEC RADIANT-IBDatasheet · Size it for your load | 60 kW | Modular, 20 kVA modules | VRLA, inside | 94 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| APC2 models at this size | 40 kW / 50 kW | Modular, 25 kW modules | VRLA, inside | 94.3 % – 94.8 % | 21.7 × 33.4 in (550 × 847 mm) | 1 yr / not stated |
75 to 100 kVA
| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| RAD90-6X15AEC RADIANTDatasheet · Size it for your load | 90 kW | Modular, 15 kVA modules | VRLA, external bank | 94 % | 17.4 × 33.1 in (442 × 840 mm) | 3 years on UPS · 2 years on VRLA batteries |
| RADIB100-5X20AEC RADIANT-IBDatasheet · Size it for your load | 100 kW | Modular, 20 kVA modules | VRLA, inside | 94 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| APC1 model at this size | 90 kW | Modular, 10 kW modules | VRLA, inside | — | 47.2 × 42.1 in (1,199 × 1,069 mm) | 1 yr / not stated |
30–150 kVA 480 V UPS with internal batteries
AEC CIRRO-IB vs APC.
30 to 60 kVA
- Warranty, UPS / battery3 years on UPS · 2 years on VRLA batteriesCIRIB150-1X30 · best rival 1 yr / not stated, APC
- Efficiency, onlineAPC: 97 %
- Footprint W × DAPC: 20.5 × 33.4 in (521 × 847 mm), VRLA
90 to 150 kVA
- Warranty, UPS / battery3 years on UPS · 2 years on VRLA batteriesCIRIB150-3X30 · best rival 1 yr / not stated, APC
- Efficiency, onlineAPC: 97.3 %
- Footprint W × DAPC: 21.7 × 33.4 in (551 × 847 mm), VRLA
30 to 60 kVA
| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIRIB150-1X30AEC CIRRO-IBDatasheet · Size it for your load | 30 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| CIRIB150-2X30AEC CIRRO-IBDatasheet · Size it for your load | 60 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| APC2 models at this size | 30 kW / 50 kW | Modular, 20 or 50 kW modules | VRLA, inside | 97 % | 20.5 × 33.4 in (521 × 847 mm) | 1 yr / not stated |
90 to 150 kVA
| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIRIB150-3X30AEC CIRRO-IBDatasheet · Size it for your load | 90 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| CIRIB150-4X30AEC CIRRO-IBDatasheet · Size it for your load | 120 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| CIRIB150-5X30AEC CIRRO-IBDatasheet · Size it for your load | 150 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| APC2 models at this size | 100 kW | Single unit / Modular, 20 or 50 kW modules | External / VRLA, inside | 96.6 % – 97.3 % | 21.7 × 33.4 in (551 × 847 mm) (GVSUPS100KB5GS); 20.5 × 33.4 in (521 × 847 mm) (GVSUPS100KGS) | 1 yr / not stated |
Large 480 V UPS
AEC INFINITE vs APC.
200 to 600 kW
- Warranty, UPS / battery3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteriesINF-200 · best rival 1 yr / not stated, APC
750 to 1,500 kW
- Efficiency, online97.5 %INF15-750 · best rival 96 %, APC
- UPS weight per kW4.11 lb (1.87 kg)INF15-1500 · best rival 6.05 lb (2.74 kg), APC
- Warranty, UPS / battery3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteriesINF15-750 · best rival 1 yr / not stated, APC
200 to 600 kW
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| INF-200AEC INFINITEDatasheet · Size it for your load | 200 kW | Modular, 100 kVA modules | 97.3 % | 591 lb (268 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF-200+1AEC INFINITEDatasheet · Size it for your load | 200 kW | Modular, 100 kVA modules | 97.3 % | 710 lb (322 kg) | 3.55 lb (1.61 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF-400AEC INFINITE · 2 frames in parallelDatasheet · Size it for your load | 400 kW | Modular, 100 kVA modules | 97.3 % | 1,183 lb (536 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF-600AEC INFINITE · 3 frames in parallelDatasheet · Size it for your load | 600 kW | Modular, 100 kVA modules | 97.3 % | 1,774 lb (805 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| APC1 model at this size | 500 kW | Modular | 97.1 % | 1,715 lb (778 kg) | 3.43 lb (1.56 kg) | 1 yr / not stated |
750 to 1,500 kW
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| INF15-750AEC INFINITE 1.5MWDatasheet · Size it for your load | 750 kW | Modular, 125 kVA modules | 97.5 % | 5,456 lb (2,475 kg) | 7.28 lb (3.30 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF15-1000AEC INFINITE 1.5MWDatasheet · Size it for your load | 1,000 kW | Modular, 125 kVA modules | 97.5 % | 5,695 lb (2,583 kg) | 5.69 lb (2.58 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF15-1250AEC INFINITE 1.5MWDatasheet · Size it for your load | 1,250 kW | Modular, 125 kVA modules | 97.5 % | 5,933 lb (2,691 kg) | 4.75 lb (2.15 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF15-1500AEC INFINITE 1.5MWDatasheet · Size it for your load | 1,500 kW | Modular, 125 kVA modules | 97.5 % | 6,171 lb (2,799 kg) | 4.11 lb (1.87 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| APC4 models at this size | 750 kW / 1,000 kW / 1,250 kW / 1,500 kW | — | 95.9 % – 96 % | 5,503 lb (2,496 kg) (GVX750K1500GS); 6,693 lb (3,036 kg) (GVX1000K1500GS); 7,884 lb (3,576 kg) (GVX1250K1500GS); 9,074 lb (4,116 kg) (GVX1500K1500GS) | 6.05 lb (2.74 kg) – 7.34 lb (3.33 kg) | 1 yr / not stated |
Modular 480 V UPS up to 1,600 kVA
AEC CIRRO vs APC.
100 to 400 kVA
- Warranty, UPS / battery3 years on UPS · 2 years on VRLA batteriesCIR360-2X60 · best rival 1 yr / not stated, APC
- Efficiency, onlineAPC: 97.3 %
500 to 800 kVA
- UPS weight per kW2.38 lb (1.08 kg)CIR800-8X100 · best rival 3.43 lb (1.56 kg), APC
- Warranty, UPS / battery3 years on UPS · 2 years on VRLA batteriesCIR600-6X100 · best rival 1 yr / not stated, APC
1,000 to 1,600 kVA
- Efficiency, online97 %CIR1200-12X100 · best rival 96 %, APC
- UPS weight per kW2.18 lb (0.99 kg)CIR1200-12X100 · best rival 6.05 lb (2.74 kg), APC
- Warranty, UPS / battery3 years on UPS · 2 years on VRLA batteriesCIR1200-12X100 · best rival 1 yr / not stated, APC
100 to 400 kVA
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIR360-2X60AEC CIRRODatasheet · Size it for your load | 120 kW | Modular, 60 kVA modules | 96 % | 727 lb (330 kg) | 6.06 lb (2.75 kg) | 3 years on UPS · 2 years on VRLA batteries |
| CIR360-4X60AEC CIRRODatasheet · Size it for your load | 240 kW | Modular, 60 kVA modules | 96 % | 908 lb (412 kg) | 3.78 lb (1.72 kg) | 3 years on UPS · 2 years on VRLA batteries |
| CIR360-6X60AEC CIRRODatasheet · Size it for your load | 360 kW | Modular, 60 kVA modules | 96 % | 1,088 lb (494 kg) | 3.02 lb (1.37 kg) | 3 years on UPS · 2 years on VRLA batteries |
| APC1 model at this size | 100 kW | Single unit | 97.3 % | 551 lb (250 kg) | 5.51 lb (2.50 kg) | 1 yr / not stated |
500 to 800 kVA
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIR600-6X100AEC CIRRODatasheet · Size it for your load | 600 kW | Modular, 100 kVA modules | 97 % | 1,515 lb (687 kg) | 2.52 lb (1.14 kg) | 3 years on UPS · 2 years on VRLA batteries |
| CIR800-8X100AEC CIRRODatasheet · Size it for your load | 800 kW | Modular, 100 kVA modules | 97 % | 1,902 lb (863 kg) | 2.38 lb (1.08 kg) | 3 years on UPS · 2 years on VRLA batteries |
| APC2 models at this size | 500 kW / 750 kW | Modular | 96 % – 97.1 % | 1,715 lb (778 kg) (Galaxy VL); 5,503 lb (2,496 kg) (Galaxy VX) | 3.43 lb (1.56 kg) – 7.34 lb (3.33 kg) | 1 yr / not stated |
1,000 to 1,600 kVA
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIR1200-12X100AEC CIRRODatasheet · Size it for your load | 1,200 kW | Modular, 100 kVA modules | 97 % | 2,619 lb (1,188 kg) | 2.18 lb (0.99 kg) | 3 years on UPS · 2 years on VRLA batteries |
| CIR1600-16X100AEC CIRRODatasheet · Size it for your load | 1,600 kW | Modular, 100 kVA modules | 97 % | 3,796 lb (1,722 kg) | 2.37 lb (1.08 kg) | 3 years on UPS · 2 years on VRLA batteries |
| APC3 models at this size | 1,000 kW / 1,250 kW / 1,500 kW | — | 95.9 % – 96 % | 6,693 lb (3,036 kg) (GVX1000K1500GS); 7,884 lb (3,576 kg) (GVX1250K1500GS); 9,074 lb (4,116 kg) (GVX1500K1500GS) | 6.05 lb (2.74 kg) – 6.69 lb (3.04 kg) | 1 yr / not stated |
Questions
AEC or APC?
Is AEC a good alternative to APC?
Yes, in the 7 size classes on this page, where 25 APC models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 10.5 min for the APC SRT1000RMXLA (VRLA); runtime, half load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 27 min against 25.4 min for the APC SRT1000RMXLA (VRLA); runtime, full load at 10 kVA, the AEC ETH10-1X50A-LI (lithium) with 14 min against 10.5 min for the APC GVSUPS10KB4FS (VRLA). Where APC's leads: depth at 1.5 kVA against AEC LUMINA, the APC SMT1500RM2UC with 18.8 in (478 mm); runtime, full load at 10 kVA against AEC AUREON, the APC GVSUPS10KB4FS (VRLA) with 10.5 min. The cards above each table give every column, size by size.
Which AEC UPS replaces an APC 120 V?
The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 1 APC model; 1.5 kVA: LUM1500RT-2U-LI against 2 APC models; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 1 APC model; 3 kVA: LUM3000RT-2U-LI against 3 APC models.
Which AEC UPS replaces an APC 208 V?
The AEC ETHERNO: 10 kVA: ETH10-1X50A-LI, ETH10-2X50A-LI, ETH10-3X50A-LI against 2 APC models; 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 2 APC models; 30 kVA: ETH30-3X50A-LI against 2 APC models. The AEC AUREON: 10 kVA: AUR10-40X9A, AUR10-80X9A against 2 APC models; 20 kVA: AUR20-60X9A, AUR20-80X9A against 2 APC models; 30 kVA: AUR30-80X9A against 2 APC models.
Where do the APC figures come from?
From APC's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two APC documents disagree, the more conservative figure is used.
Sources
Where the APC figures come from
APC: 25 models, documents read 10 Oct 2026
- SRT1000RMXLA: Schneider Electric_APC-SmartUPS-OnLine_SRT1000RMXLA.pdf (se.com); SRT1000RMXLA (se.com); 998-1257966_202101_GMA-US_B_2022.pdf (download.schneider-electric.com).
- SMT1500RM2UC: Schneider Electric_APC-SmartUPS_SMT1500RM2UC.pdf (se.com); SMT1500RM2UC (se.com); EcoStruxure Ready Smart-UPS with APC SmartConnect Brochure Americas_V9.pdf (download.schneider-electric.com); SU UM JPS29633 MN01 EN.pdf (download.schneider-electric.com).
- SRT1500RMXLA: Schneider Electric_APC-SmartUPS-OnLine_SRT1500RMXLA.pdf (se.com); SRT1500RMXLA (se.com); 998-1257966_202101_GMA-US_B_2022.pdf (download.schneider-electric.com).
- SRT2200RMXLA: Schneider Electric_APC-SmartUPS-OnLine_SRT2200RMXLA.pdf (se.com); SRT2200RMXLA (se.com); 998-1257966_202101_GMA-US_B_2022.pdf (download.schneider-electric.com); JGNY-9U4AMZ_R1_EN.pdf (download.schneider-electric.com).
- SMT3000RM2UC: Schneider Electric_APC-SmartUPS_SMT3000RM2UC.pdf (se.com); EcoStruxure Ready Smart-UPS with APC SmartConnect Brochure Americas_V9.pdf (download.schneider-electric.com); SU UM JPS29633 MN01 EN.pdf (download.schneider-electric.com).
- SRT3000RMXLA: Schneider Electric_APC-SmartUPS-OnLine_SRT3000RMXLA.pdf (se.com); SRT3000RMXLA (se.com); 998-1257966_202101_GMA-US_B_2022.pdf (download.schneider-electric.com); JGNY-9U4AMZ_R1_EN.pdf (download.schneider-electric.com).
- SRTL3KRM1UC: Schneider Electric_APC-SmartUPS-Ultra_SRTL3KRM1UC.pdf (se.com); SRTL3KRM1UC (se.com); APC Smart-UPS Ultra up to 10kW NAM Brochure.pdf (download.schneider-electric.com); SUO UM 990-6315A MN01 EN.pdf (download.schneider-electric.com).
- GVSUPS10KB4FS: GVSUPS10KB4FS.pdf (se.com); 990-91318_EN (download.se.com); Galaxy VS UL Brochure.pdf (download.schneider-electric.com).
- E3SUPS10KFBS: E3SUPS10KFBS.pdf (se.com); 990-6408D_EN.pdf (productinfo.schneider-electric.com); se.com/…/65643-easy-ups-3s.
- GVSUPS20KB4FS: GVSUPS20KB4FS.pdf (se.com); GVSUPS20KB4FS (se.com); 990-91318_EN (download.se.com); Galaxy VS UL Brochure.pdf (download.schneider-electric.com).
- E3SUPS20KFBS: E3SUPS20KFBS.pdf (se.com); 990-6408D_EN.pdf (productinfo.schneider-electric.com); se.com/…/65643-easy-ups-3s.
- GVSUPS30KB5FS: GVSUPS30KB5FS.pdf (se.com); 990-91318_EN (download.se.com); Galaxy VS UL Brochure.pdf (download.schneider-electric.com).
- E3SUPS30KFBS: E3SUPS30KFBS.pdf (se.com); 990-6408D_EN.pdf (productinfo.schneider-electric.com); se.com/…/65643-easy-ups-3s.
- GVSUPS40KB5FS: 990-91318H_EN.pdf (productinfo.schneider-electric.com).
- GVSUPS50KB5FS: 990-91318H_EN.pdf (productinfo.schneider-electric.com); GVSUPS50KB5FS (se.com); Schneider Electric_Galaxy-VS_GVSUPS50KB5FS.pdf (se.com).
- SY90K100F: SY90K100F (se.com); Schneider Electric_Symmetra-PX_SY90K100F.pdf (se.com); SYPM10KF2 (se.com).
- GVSUPS30KB4GS: 990-91318H_EN.pdf (productinfo.schneider-electric.com).
- GVSUPS50KB4GS: 990-91318H_EN.pdf (productinfo.schneider-electric.com).
- GVSUPS100KGS: GVSUPS100KGS.pdf (se.com); 990-91140_EN (download.se.com); 990-91140_EN (se.com); Galaxy VS UL Brochure.pdf (download.schneider-electric.com).
- GVSUPS100KB5GS: 990-91318H_EN.pdf (productinfo.schneider-electric.com).
- GVL500KDS: GVL500KDS.pdf (se.com); GVL500KDS (se.com); 990-91399_EN (download.se.com).
- GVX750K1500GS: 990-5451L_EN.pdf (productinfo.schneider-electric.com).
- GVX1000K1500GS: 990-5451L_EN.pdf (productinfo.schneider-electric.com).
- GVX1250K1500GS: 990-5451L_EN.pdf (productinfo.schneider-electric.com).
- GVX1500K1500GS: 990-5451L_EN.pdf (productinfo.schneider-electric.com); GVX1500K1500GS.pdf (se.com).
Rival figures from each maker's own published documents, read 10 Oct 2026 and named model by model under Sources; where two of a maker's documents disagree, the more conservative figure is used. AEC figures from the AEC 2026 catalog. Efficiency is the online (double-conversion) figure, not ECO mode. Weights and footprints compared only for units with their batteries inside; a weight marked UPS only leaves the battery cabinets out. Weights per kW are of the UPS alone, without batteries. Brand and model names are trademarks of their owners; AEC is not affiliated with them and names their models only to compare them.
Replacing an APC UPS?
Send the APC model or its label and the load: we reply with the AEC model, the runtime and the lead time.