AEC vs Toshiba
AEC against Toshiba, model by model.
The AEC alternative to Toshiba, size class by size class: AEC LUMINA for the T1000; AEC ETHERNO for the 4400 and 1100 TP; AEC RADIANT for the 1100 TP; AEC CIRRO-IB for the 3000 TP and G9000; AEC INFINITE for the G9000 and 3000 TP; AEC CIRRO for the G9000 and 3000 TP.
1–3 kVA rack UPS, 120 V
AEC LUMINA vs Toshiba.
1 kVA
- Runtime, full load11 minLUM1000RT-2U-LI, lithium · best rival 5 min, Toshiba, VRLA
- Efficiency, online91.7 %LUM1000RT-2U-LI · best rival 86 %, Toshiba
- Weight20 lb (9 kg)LUM1000RT-2U-LI, lithium · best rival 36 lb (16 kg), Toshiba, VRLA
- Warranty, UPS / battery5 years incl. lithium batteriesLUM1000RT-2U-LI · best rival 3 yr / 2 yr, Toshiba
1.5 kVA
- Runtime, full load11 minLUM1500RT-2U-LI, lithium · best rival 5 min, Toshiba, VRLA
- Efficiency, online92.5 %LUM1500RT-2U-LI · best rival 86 %, Toshiba
- Weight32 lb (15 kg)LUM1500RT-2U-LI, lithium · best rival 39 lb (18 kg), Toshiba, VRLA
- Warranty, UPS / battery5 years incl. lithium batteriesLUM1500RT-2U-LI · best rival 3 yr / 2 yr, Toshiba
- DepthToshiba: 19.7 in (500 mm)
2 to 2.2 kVA
- Runtime, full load23 minLUM2200RT-2U-LI, lithium · best rival 5 min, Toshiba, VRLA
- Efficiency, online92.5 %LUM2000RT-2U-LI · best rival 86 %, Toshiba
- Depth22.4 in (570 mm)LUM2000RT-2U-LI · best rival 25 in (635 mm), Toshiba
- Weight30 lb (14 kg)LUM2000RT-2U-LI, lithium · best rival 66 lb (30 kg), Toshiba, VRLA
- Warranty, UPS / battery5 years incl. lithium batteriesLUM2000RT-2U-LI · best rival 3 yr / 2 yr, Toshiba
3 kVA
- Runtime, full load11 minLUM3000RT-2U-LI, lithium · best rival 5 min, Toshiba, VRLA
- Efficiency, online92.5 %LUM3000RT-2U-LI · best rival 86 %, Toshiba
- Depth22.4 in (570 mm)LUM3000RT-2U-LI · best rival 25 in (635 mm), Toshiba
- Weight38 lb (17 kg)LUM3000RT-2U-LI, lithium · best rival 74 lb (34 kg), Toshiba, VRLA
- Warranty, UPS / battery5 years incl. lithium batteriesLUM3000RT-2U-LI · best rival 3 yr / 2 yr, Toshiba
1 kVA
| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|---|---|
| LUM1000RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 900 W | 11 min | 27 min | 91.7 % | 2U | 16.5 in (420 mm) | 20 lb (9 kg) | 5 years incl. lithium batteries |
| Toshiba1 model at this size | Online | VRLA, inside | 900 W | 5 min | — | 86 % | 2U | 16.7 in (424 mm) | 36 lb (16 kg) | 3 yr / 2 yr |
1.5 kVA
| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|---|---|
| LUM1500RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 1,350 W | 11 min | 27 min (AEC runtime table) | 92.5 % | 2U | 22.6 in (574 mm) | 32 lb (15 kg) | 5 years incl. lithium batteries |
| Toshiba1 model at this size | Online | VRLA, inside | 1,350 W | 5 min | — | 86 % | 2U | 19.7 in (500 mm) | 39 lb (18 kg) | 3 yr / 2 yr |
2 to 2.2 kVA
| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|---|---|
| LUM2000RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 1,800 W | 11 min | 27 min | 92.5 % | 2U | 22.4 in (570 mm) | 30 lb (14 kg) | 5 years incl. lithium batteries |
| LUM2200RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 1,980 W | 23 min | 46 min | 92.6 % | 2U | 24.2 in (615 mm) | 42 lb (19 kg) | 5 years incl. lithium batteries |
| Toshiba1 model at this size | Online | VRLA, inside | 1,800 W | 5 min | — | 86 % | 2U | 25 in (635 mm) | 66 lb (30 kg) | 3 yr / 2 yr |
3 kVA
| Model | Type | Battery | Output | Runtime, full load | Runtime, half load | Efficiency, online | Rack units | Depth | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|---|---|
| LUM3000RT-2U-LIAEC LUMINADatasheet · Size it for your load | Online | Lithium, inside | 2,700 W | 11 min | 27 min | 92.5 % | 2U | 22.4 in (570 mm) | 38 lb (17 kg) | 5 years incl. lithium batteries |
| Toshiba1 model at this size | Online | VRLA, inside | 2,700 W | 5 min | — | 86 % | 2U | 25 in (635 mm) | 74 lb (34 kg) | 3 yr / 2 yr |
10–30 kVA three-phase UPS, 208 V
AEC ETHERNO vs Toshiba.
20 kVA
- Efficiency, online94 %ETH20-2X50A-LI · best rival 92.9 %, Toshiba
- Warranty, UPS / battery5 yearsETH20-2X50A-LI · best rival 3 yr / not stated, Toshiba
30 kVA
- Efficiency, online94 %ETH30-3X50A-LI · best rival 92.9 %, Toshiba
- Warranty, UPS / battery5 yearsETH30-3X50A-LI · best rival 3 yr / not stated, Toshiba
20 kVA
| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|
| ETH20-2X50A-LIAEC ETHERNODatasheet · Size it for your load | 20 kW | Lithium, 2 × 50 Ah modules, inside | 14 min | 27 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 390 lb (177 kg) | 5 years |
| ETH20-3X50A-LIAEC ETHERNODatasheet · Size it for your load | 20 kW | Lithium, 3 × 50 Ah modules, inside | 20 min | 41 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 472 lb (214 kg) | 5 years |
| Toshiba2 models at this size | 18 kW | Not stated, inside / External | — | — | 91 % – 92.9 % | 20.1 × 37.4 in (511 × 950 mm) (4400); 19.7 × 27 in (500 × 686 mm) (1100 TP) | 720 lb (327 kg) (UPS only) (4400); 331 lb (150 kg) (UPS only) (1100 TP) | 3 yr / not stated |
30 kVA
| Model | Output | Battery | Runtime, full load | Runtime, half load | Efficiency, online | Footprint W × D | Weight | Warranty, UPS / battery |
|---|---|---|---|---|---|---|---|---|
| ETH30-3X50A-LIAEC ETHERNODatasheet · Size it for your load | 30 kW | Lithium, 3 × 50 Ah modules, inside | 14 min | 27 min | 94 % | 12.6 × 39.1 in (320 × 993 mm) | 485 lb (220 kg) | 5 years |
| Toshiba2 models at this size | 27 kW | Not stated, inside / External | — | — | 91 % – 92.9 % | 20.1 × 37.4 in (511 × 950 mm) (4400); 19.7 × 27 in (500 × 686 mm) (1100 TP) | 720 lb (327 kg) (UPS only) (4400); 375 lb (170 kg) (UPS only) (1100 TP) | 3 yr / not stated |
Modular three-phase UPS, 208 V
AEC RADIANT vs Toshiba.
15 to 30 kVA
- Efficiency, online94 %RAD90-1X15 · best rival 92.9 %, Toshiba
15 to 30 kVA
| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| RAD90-1X15AEC RADIANTDatasheet · Size it for your load | 15 kW | Modular, 15 kVA modules | VRLA, external bank | 94 % | 17.4 × 33.1 in (442 × 840 mm) | 3 years on UPS · 2 years on VRLA batteries |
| RAD90-2X15AEC RADIANTDatasheet · Size it for your load | 30 kW | Modular, 15 kVA modules | VRLA, external bank | 94 % | 17.4 × 33.1 in (442 × 840 mm) | 3 years on UPS · 2 years on VRLA batteries |
| RADIB100-1X20AEC RADIANT-IBDatasheet · Size it for your load | 20 kW | Modular, 20 kVA modules | VRLA, inside | 94 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| Toshiba2 models at this size | 18 kW / 27 kW | Modular | External | 92.9 % | 19.7 × 27 in (500 × 686 mm) | 3 yr / not stated |
30–150 kVA 480 V UPS with internal batteries
AEC CIRRO-IB vs Toshiba.
30 to 60 kVA
90 to 150 kVA
- Efficiency, onlineToshiba: 96.6 %
30 to 60 kVA
| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIRIB150-1X30AEC CIRRO-IBDatasheet · Size it for your load | 30 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| CIRIB150-2X30AEC CIRRO-IBDatasheet · Size it for your load | 60 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| Toshiba1 model at this size | 40 kW | Modular | Not stated | 96.5 % | 23.5 × 33.5 in (597 × 851 mm) | 3 yr / not stated |
90 to 150 kVA
| Model | Output | Architecture | Battery | Efficiency, online | Footprint W × D | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIRIB150-3X30AEC CIRRO-IBDatasheet · Size it for your load | 90 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| CIRIB150-4X30AEC CIRRO-IBDatasheet · Size it for your load | 120 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| CIRIB150-5X30AEC CIRRO-IBDatasheet · Size it for your load | 150 kW | Modular, 30 kVA modules | VRLA, inside | 96 % | 23.6 × 39.3 in (599 × 998 mm) | 3 years on UPS · 2 years on VRLA batteries |
| Toshiba2 models at this size | 90 kW / 144 kW | — | External | 96.4 % – 96.6 % | 27.6 × 32.8 in (701 × 833 mm) | 3 yr / not stated |
Large 480 V UPS
AEC INFINITE vs Toshiba.
200 to 600 kW
- UPS weight per kW2.96 lb (1.34 kg)INF-200 · best rival 5.33 lb (2.42 kg), Toshiba
750 to 1,500 kW
200 to 600 kW
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| INF-200AEC INFINITEDatasheet · Size it for your load | 200 kW | Modular, 100 kVA modules | 97.3 % | 591 lb (268 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF-200+1AEC INFINITEDatasheet · Size it for your load | 200 kW | Modular, 100 kVA modules | 97.3 % | 710 lb (322 kg) | 3.55 lb (1.61 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF-400AEC INFINITE · 2 frames in parallelDatasheet · Size it for your load | 400 kW | Modular, 100 kVA modules | 97.3 % | 1,183 lb (536 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF-600AEC INFINITE · 3 frames in parallelDatasheet · Size it for your load | 600 kW | Modular, 100 kVA modules | 97.3 % | 1,774 lb (805 kg) | 2.96 lb (1.34 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| Toshiba4 models at this size | 202.5 kW / 300 kW / 500 kW / 200 kW | Modular | 96.5 % – 97 % | 1,080 lb (490 kg) (T90S3S22KS6XSN2); 2,260 lb (1,025 kg) (T90S3S30KS6XSN); 3,300 lb (1,497 kg) (T90S3S50KS6XSN); 1,160 lb (526 kg) (3000 TP) | 5.33 lb (2.42 kg) (T90S3S22KS6XSN2); 6.60 lb (2.99 kg) (T90S3S50KS6XSN); 7.53 lb (3.42 kg) (T90S3S30KS6XSN) | 3 yr / not stated |
750 to 1,500 kW
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| INF15-750AEC INFINITE 1.5MWDatasheet · Size it for your load | 750 kW | Modular, 125 kVA modules | 97.5 % | 5,456 lb (2,475 kg) | 7.28 lb (3.30 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF15-1000AEC INFINITE 1.5MWDatasheet · Size it for your load | 1,000 kW | Modular, 125 kVA modules | 97.5 % | 5,695 lb (2,583 kg) | 5.69 lb (2.58 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF15-1250AEC INFINITE 1.5MWDatasheet · Size it for your load | 1,250 kW | Modular, 125 kVA modules | 97.5 % | 5,933 lb (2,691 kg) | 4.75 lb (2.15 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| INF15-1500AEC INFINITE 1.5MWDatasheet · Size it for your load | 1,500 kW | Modular, 125 kVA modules | 97.5 % | 6,171 lb (2,799 kg) | 4.11 lb (1.87 kg) | 3 years on UPS, 5 if registered · 5 years on lithium cabinets incl. batteries |
| Toshiba1 model at this size | 750 kW | — | 97 % | 4,250 lb (1,928 kg) | 5.67 lb (2.57 kg) | 3 yr / not stated |
Modular 480 V UPS up to 1,600 kVA
AEC CIRRO vs Toshiba.
100 to 400 kVA
- UPS weight per kW3.02 lb (1.37 kg)CIR360-6X60 · best rival 5.33 lb (2.42 kg), Toshiba
- Efficiency, onlineToshiba: 96.6 %
500 to 800 kVA
- UPS weight per kW2.38 lb (1.08 kg)CIR800-8X100 · best rival 5.67 lb (2.57 kg), Toshiba
100 to 400 kVA
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIR360-2X60AEC CIRRODatasheet · Size it for your load | 120 kW | Modular, 60 kVA modules | 96 % | 727 lb (330 kg) | 6.06 lb (2.75 kg) | 3 years on UPS · 2 years on VRLA batteries |
| CIR360-4X60AEC CIRRODatasheet · Size it for your load | 240 kW | Modular, 60 kVA modules | 96 % | 908 lb (412 kg) | 3.78 lb (1.72 kg) | 3 years on UPS · 2 years on VRLA batteries |
| CIR360-6X60AEC CIRRODatasheet · Size it for your load | 360 kW | Modular, 60 kVA modules | 96 % | 1,088 lb (494 kg) | 3.02 lb (1.37 kg) | 3 years on UPS · 2 years on VRLA batteries |
| Toshiba5 models at this size | 90 kW / 144 kW / 202.5 kW / 300 kW / 200 kW | Modular | 96.4 % – 97 % | 772 lb (350 kg) (T90S3S10KS6XSN2); 860 lb (390 kg) (T90S3S16KS6XSN2); 1,080 lb (490 kg) (T90S3S22KS6XSN2); 2,260 lb (1,025 kg) (T90S3S30KS6XSN); 1,160 lb (526 kg) (3000 TP) | 5.33 lb (2.42 kg) (T90S3S22KS6XSN2); 5.97 lb (2.71 kg) (T90S3S16KS6XSN2); 7.53 lb (3.42 kg) (T90S3S30KS6XSN); 8.58 lb (3.89 kg) (T90S3S10KS6XSN2) | 3 yr / not stated |
500 to 800 kVA
| Model | Output | Architecture | Efficiency, online | Weight | UPS weight per kW | Warranty, UPS / battery |
|---|---|---|---|---|---|---|
| CIR600-6X100AEC CIRRODatasheet · Size it for your load | 600 kW | Modular, 100 kVA modules | 97 % | 1,515 lb (687 kg) | 2.52 lb (1.14 kg) | 3 years on UPS · 2 years on VRLA batteries |
| CIR800-8X100AEC CIRRODatasheet · Size it for your load | 800 kW | Modular, 100 kVA modules | 97 % | 1,902 lb (863 kg) | 2.38 lb (1.08 kg) | 3 years on UPS · 2 years on VRLA batteries |
| Toshiba2 models at this size | 500 kW / 750 kW | — | 97 % | 3,300 lb (1,497 kg) (T90S3S50KS6XSN); 4,250 lb (1,928 kg) (T90S3S75KS6XSN) | 5.67 lb (2.57 kg) – 6.60 lb (2.99 kg) | 3 yr / not stated |
Questions
AEC or Toshiba?
Is AEC a good alternative to Toshiba?
Yes, in the 6 size classes on this page, where 16 Toshiba models are compared with AEC's, each in the configuration its datasheet lists (the Battery column says which). Where AEC's figure leads: runtime, full load at 1 kVA, the AEC LUM1000RT-2U-LI (lithium) with 11 min against 5 min for the Toshiba T1S0A1000AXAR2 (VRLA); efficiency, online at 1 kVA, the AEC LUM1000RT-2U-LI with 91.7 % against 86 % for the Toshiba T1S0A1000AXAR2; efficiency, online at 20 kVA, the AEC ETH20-2X50A-LI with 94 % against 92.9 % for the Toshiba 11A0H020KCXC. Where Toshiba's leads: depth at 1.5 kVA against AEC LUMINA, the Toshiba T1S0A1500AXAR2 with 19.7 in (500 mm); efficiency, online at 90 to 150 kVA against AEC CIRRO-IB, the Toshiba T90S3S10KS6XSN2 with 96.6 %. The cards above each table give every column, size by size.
Which AEC UPS replaces a Toshiba 120 V?
The AEC LUMINA: 1 kVA: LUM1000RT-2U-LI against 1 Toshiba model; 1.5 kVA: LUM1500RT-2U-LI against 1 Toshiba model; 2 to 2.2 kVA: LUM2000RT-2U-LI, LUM2200RT-2U-LI against 1 Toshiba model; 3 kVA: LUM3000RT-2U-LI against 1 Toshiba model.
Which AEC UPS replaces a Toshiba 208 V?
The AEC ETHERNO: 20 kVA: ETH20-2X50A-LI, ETH20-3X50A-LI against 2 Toshiba models; 30 kVA: ETH30-3X50A-LI against 2 Toshiba models.
Which AEC UPS replaces a Toshiba Modular three-phase UPS, 208 V?
The AEC RADIANT: 15 to 30 kVA: RAD90-1X15, RAD90-2X15, RADIB100-1X20 against 2 Toshiba models.
Where do the Toshiba figures come from?
From Toshiba's own published documents, read 10 Oct 2026; each one is named, model by model, under Sources. Where two Toshiba documents disagree, the more conservative figure is used.
Sources
Where the Toshiba figures come from
Toshiba: 16 models, documents read 10 Oct 2026
- T1S0A1000AXAR2: toshiba.com/…/t1000-series-single-phase-double-conversion-ups; Toshiba-PED-Specifications-T1000-1-3kVA-scaled.jpg (toshiba.com); toshiba.com/…/single-phase-ups.
- T1S0A1500AXAR2: toshiba.com/…/t1000-series-single-phase-double-conversion-ups; Toshiba-PED-Specifications-T1000-1-3kVA-scaled.jpg (toshiba.com); toshiba.com/…/single-phase-ups.
- T1S0A2000AXAR2: toshiba.com/…/t1000-series-single-phase-double-conversion-ups; Toshiba-PED-Specifications-T1000-1-3kVA-scaled.jpg (toshiba.com); toshiba.com/…/single-phase-ups.
- T1S0A3000AXAR2: toshiba.com/…/t1000-series-single-phase-double-conversion-ups; Toshiba-PED-Specifications-T1000-1-3kVA-scaled.jpg (toshiba.com); toshiba.com/…/single-phase-ups.
- 4400X3X200XA: toshiba.com/…/4400-series-3-phase-ups; Toshiba-PED-Specifications-4400-scaled.jpg (toshiba.com).
- 11A0H020KCXC: toshiba.com/…/1100-tp-series-ups; 1100-TP-Series-UPS-Specifications-scaled.jpg (toshiba.com).
- 4400X3X300XA: toshiba.com/…/4400-series-3-phase-ups; Toshiba-PED-Specifications-4400-scaled.jpg (toshiba.com).
- 11A0H030KCXC: toshiba.com/…/1100-tp-series-ups; 1100-TP-Series-UPS-Specifications-scaled.jpg (toshiba.com).
- 30S0G040KWWW: toshiba.com/…/3000-tp-series-ups; 3000TP-Web-Specifications.jpg (toshiba.com); 3000-TP_Web_Standard-Configurations-1024x451.png (toshiba.com).
- T90S3S10KS6XSN2: toshiba.com/…/g9000-series-100-1050kva; Toshiba-PED-Specifications-G9000.jpg (toshiba.com).
- T90S3S16KS6XSN2: toshiba.com/…/g9000-series-100-1050kva; Toshiba-PED-Specifications-G9000.jpg (toshiba.com).
- T90S3S22KS6XSN2: toshiba.com/…/g9000-series-100-1050kva; Toshiba-PED-Specifications-G9000.jpg (toshiba.com).
- T90S3S30KS6XSN: toshiba.com/…/g9000-series-100-1050kva; Toshiba-PED-Specifications-G9000.jpg (toshiba.com).
- T90S3S50KS6XSN: toshiba.com/…/g9000-series-100-1050kva; Toshiba-PED-Specifications-G9000.jpg (toshiba.com).
- 30S0G200KWWW: toshiba.com/…/3000-tp-series-ups; 3000TP-Web-Specifications.jpg (toshiba.com); 3000-TP_Web_Standard-Configurations-1024x451.png (toshiba.com).
- T90S3S75KS6XSN: toshiba.com/…/g9000-series-100-1050kva; Toshiba-PED-Specifications-G9000.jpg (toshiba.com).
Rival figures from each maker's own published documents, read 10 Oct 2026 and named model by model under Sources; where two of a maker's documents disagree, the more conservative figure is used. AEC figures from the AEC 2026 catalog. Efficiency is the online (double-conversion) figure, not ECO mode. Weights and footprints compared only for units with their batteries inside; a weight marked UPS only leaves the battery cabinets out. Weights per kW are of the UPS alone, without batteries. Brand and model names are trademarks of their owners; AEC is not affiliated with them and names their models only to compare them.
AEC against the other makers:AEC vs APCAEC vs VertivAEC vs EatonAEC vs Tripp LiteAEC vs CyberPowerAEC vs Xtreme PowerAEC vs DeltaAll comparisons
Replacing a Toshiba UPS?
Send the Toshiba model or its label and the load: we reply with the AEC model, the runtime and the lead time.