IST3-J · Single-phase UPS

IST3-J 6 kVA Online rack UPS 6 kVA, 2U, 230 V

VRLA6 kVAonline rack UPS, 2U, 230 V

The IST3-J 6 kVA is a 6 kVA / 6 kW single-phase online double-conversion UPS in a 2U chassis of 10.6 kg, a long backup model that runs on an external battery. For racks that need 5 kW of protected power and a backup time chosen by the number of battery cabinets.

6 kVA / 6 kWRating
438 × 500 × 86 mmW × D × H
10.6 kgWeight

Quick answers

IST3-J 6 kVA: quick answers

What it is
The IST3-J 6 kVA is a 6 kVA / 6 kW single-phase online double-conversion UPS in a 2U chassis of 10.6 kg, a long backup model that runs on an external battery.
Who it is for
For racks that need 5 kW of protected power and a backup time chosen by the number of battery cabinets.
Supply and configuration
208 / 220 / 230 / 240 V
Battery and backup
192 V default (12–20 × 12 V settable) · external battery, any backup time
Size and weight
438 × 500 × 86 mm · 10.6 kg
Ordering code
IST3J-6 · IST3J-6/10-[n]X9

IST3-J

What sets apart the IST3-J 6 kVA

The 6 kVA has no internal batteries: its 192 V string (12 to 20 blocks of 12 V, set through communication) sits in BBJ2 rack cabinets of 3U, each with up to 16 × 12 V 9 Ah. The codes IST3J-6/10-[n]X9 go from one to eight BBJ2, 16 to 128 batteries. Input and output connect on a wire terminal; the two IEC C13 outlets take up to 10 A each.

Its input works at full load from 176 to 275 V and keeps going down to 80 V with linear derating. The overload table differs from the 1–3 kVA: 115–130% for 10 minutes, 130–150% for 30 seconds.

  • Against the IST3-J 3 kVA (one size down): Power 6000 VA / 6000 W against 3000 VA / 3000 W; Voltage range 176–275 V full load · 80–176 V linear derating against 176–295 V > 75% load · 154–176 V 50–75% · 120–154 V < 50%; Voltage 220 V ± 2% default · 208 / 220 / 230 / 240 V against 208 / 220 / 230 / 240 V ± 1%, settable; Voltage distortion THD < 1% linear · < 4% non-linear against THD < 2% (linear load); Overload 115–130% 10 min · 130–150% 30 s · > 150% 500 ms against 105–110% 10 min · 110–130% 1 min · 130–150% 1 s · > 150% 200 ms.
  • Against the IST3-J 10 kVA (one size up): Power 6000 VA / 6000 W against 10000 VA / 10000 W; Weight 10.6 kg against 12.2 kg.

Planning data

IST3-J 6 kVA: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST3-J 6 kVA.

In the rack or on the floor

IST3-J 6 kVA · In the rack or on the floor
Model6 kVA
AC input max. (A)36
AC breaker (A)50
DC input max. (A)39
DC breaker (A)50
AC cable (mm²)—
DC cable (mm²)—

Installation

Installing the IST3-J 6 kVA: space, cables

Each figure with its source.

IST3-J 6 kVA · installation
ItemFigureSource
Clearancesrear 300 mm (recommended 500), left 300 mm (recommended 500), right 300 mm (recommended 500); front and top: not givenAEC IST3-J 6–10 user manual p.6 §1.3
Cable entryRear terminal blockAEC IST3-J 6–10 user manual
Operating temperature−5 to 40 °C, best 20–25 °CAEC IST3-J 6–10 user manual p.6 §1.3
Switches and terminalsInput breaker, terminal block and the battery port on the rear panel.AEC IST3-J 6–10 user manual p.6 §1.3

Size and floor

How big it is

438 × 500 × 86 mm · 10.6 kg.

0.22 m²footprint
48 kg/m²floor load
0.09 mheight

Floor load = weight ÷ footprint (10.6 kg).

1.75 mFrontSide43850086

Efficiency

How efficient is the AEC IST3-J 6 kVA at your load?

IST3-J 6 kVA, 6 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 50%: 0.19 kW (η 94.05%) · 75%: 0.21 kW (η 95.5%) · 100%: 0.30 kW (η 95.3%). At 50% load, 24/7, it loses about 1,663 kWh a year.

95.5%75% · Typical curve, derived from the datasheet efficiency of 95.5% (AEC method)

How the curve is drawn and where each figure comes from: the IST3-J range page.

Load
—
Lost as heat
—
Energy lost in a year, 24/7
—
Its cost in a year at € per kWh
—
The catalogue's examples use €0.20 per kWh.
Where each figure comes from
ModeEfficiencyKindModelsSource
Online, double conversion30%: 93.04% · 50%: 94.05% · 75%: 95.5% · 100%: 95.3%Typical curve, derived from the datasheet efficiency of 95.5% (AEC method)IST3-J 6 kVA · IST3-J 10 kVAAEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
ECO98.3%Datasheet figure, load not statedallAEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
Online, double conversion30%: 86.14% · 50%: 88.7% · 75%: 90.06% · 100%: 90.83%Measured (AEC datasheet)IST3-J 1 kVAAEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
Online, double conversion30%: 89.36% · 50%: 91.23% · 75%: 92.16% · 100%: 92.56%Measured (AEC datasheet)IST3-J 2 kVAAEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency
Online, double conversion30%: 90.84% · 50%: 91.85% · 75%: 93.3% · 100%: 93.1%Measured (AEC datasheet)IST3-J 3 kVAAEC technical datasheet IST3-J 1–3 kVA: AC/AC efficiency

EMEA 2026 catalogue figures: Online, double conversion up to 95.5%.

AEC IST3-J 6 kVA, rendered from its 3D modelDrag to turn

In 3D

Look around the IST3-J 6 kVA

Technical data

Technical data IST3-J 6 kVA

Only this model's values, from the EMEA 2026 catalogue table.

IST3-J 6 kVA · Technical data
Rating
Power (VA / W)6000 / 6000
Efficiency (AC/AC)up to 95.5% · 98.3% in ECO mode
Input
Voltage range176–275 V full load · 80–176 V linear derating
Frequency · connection50 / 60 Hz ± 10%, self-adapting · single phase, L + N + PE, TN system
Output
Voltage220 V ± 2% default · 208 / 220 / 230 / 240 V
Frequency · waveform · transfer50 / 60 Hz ± 0.2% in battery mode · sine wave · 0 ms
Voltage distortionTHD < 1% linear · < 4% non-linear
Power factor1.0 (kVA = kW)
Overload115–130% 10 min · 130–150% 30 s · > 150% 500 ms
Output outlets2 × IEC C13 (each ≤ 10 A) + wire terminal
Battery
Battery voltage192 V default (12–20 × 12 V settable)
Backup · rechargeexternal battery, any backup time
General
CommunicationRS232 · intelligent slot options
Protectionsbattery under-voltage, overload, short circuit, over-temperature, input overvoltage
Noise< 55 dB
Environment−5 … 40 °C · 0–95% RH · < 1000 m (derate above)
Dimensions W × D × H (mm)438 × 500 × 86
Weight (kg)10.6

6 kVA: long backup model only (L). Specifications are subject to change without notice.

More technical detailsordering codes

Ordering codes

Ordering codes IST3-J 6 kVA

Ordering codes IST3-J 6 kVA
CodeDescription
IST3J-[kVA]-[n]X91–3 kVA with internal batteries plus BBJ / BBJ2 rack cabinets, n × 12 V 9 Ah in total
IST3J-6 · IST3J-106 / 10 kVA, external batteries only
IST3J-6/10-[n]X96 / 10 kVA with 1 to 8 BBJ2 cabinets, 16 to 128 × 12 V 9 Ah
BBJ · BBJ2Rack battery cabinet, max. 8 × 12 V 9 Ah (2U) · max. 16 × 12 V 9 Ah (3U)

Questions

Questions about the IST3-J 6 kVA

Does the IST3-J 6 kVA have internal batteries?

No. It is a long backup model (L): the battery is external, 192 V by default, in one to eight BBJ2 rack cabinets of 16 × 12 V 9 Ah each. The backup time is set by the battery you choose.

What breaker does the IST3-J 6 kVA need?

The catalogue recommends a 50 A upstream input breaker (36 A maximum input current) and a 50 A DC breaker for the battery, which draws up to 39 A. Size the cables on these currents.

How long does a 6 kVA UPS like the IST3-J 6 kVA run?

4 to 86 minutes at full load (6 kW), and 13 to 218 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 16 × 12 V 9 Ah (IST3J-6-16X9): 4 minutes at 100% and 13 at 50%. For other loads and batteries use the backup-time tool.

How big is the AEC IST3-J 6 kVA and how much does it weigh?

The AEC IST3-J 6 kVA measures 438 × 500 × 86 mm; weight: 10.6 kg (EMEA 2026 catalogue).

What is the ordering code of the AEC IST3-J 6 kVA?

In the EMEA 2026 catalogue the AEC IST3-J 6 kVA is listed as IST3J-6, IST3J-6/10-[n]X9; AEC gives the full code, batteries included, from the load and the backup time.

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST3-J 6 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.