IST7 60–200 · Three-phase UPS

IST7-100 Three-phase online UPS 100 kVA, 400 V

VRLA100 kVAthree-phase online UPS, 400 V

The IST7-100 is a 100 kVA / 100 kW three-phase online double-conversion UPS in a 400 mm wide cabinet, upgradable to 120 kVA from the display. For data centres, hospitals and plants with about 100 kW of critical load, alone or in parallel systems of up to eight units.

100 kVA / 100 kWRating
400 × 960 × 1193 mmW × D × H
165 kgWeight
±216 VBattery

Quick answers

IST7-100: quick answers

What it is
The IST7-100 is a 100 kVA / 100 kW three-phase online double-conversion UPS in a 400 mm wide cabinet, upgradable to 120 kVA from the display.
Who it is for
For data centres, hospitals and plants with about 100 kW of critical load, alone or in parallel systems of up to eight units.
Supply and configuration
3 phases + N + PE · 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L
Battery and backup
±216 V
Size and weight
400 × 960 × 1193 mm · 165 kg
Ordering code
IST7-100

IST7 60–200

What sets apart the IST7-100

One hundred kilowatts on 0.38 m² of floor: the IST7-100 is 400 × 960 × 1193 mm and 165 kg. The catalogue's operating-cost example is built on a 100 kW load: at the 96.5% peak efficiency the losses are 3.6 kW, about 31,800 kWh a year, and in ECO mode at 99% they drop to 1.0 kW, about 8,850 kWh.

Its default battery is ±216 V, 36 blocks of 12 V, drawing 241 A nominal and 279 A maximum on 50 mm² cables. The charger gives up to 30 A, and the charge current limit is 0.2 C for lead-acid and 0.5 C for lithium.

  • Against the IST7-80 (one size down): Rated power 100 kVA / 100 kW against 80 kVA / 80 kW; Capacity upgrade to 120 against to 100 / 120; Nominal DC voltage (default) ±216 V against ±192 V; Weight 165 kg against 163 kg.
  • Against the IST7-120 (one size up): Rated power 100 kVA / 100 kW against 120 kVA / 120 kW; Weight 165 kg against 167 kg.

Planning data

IST7-100: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST7-100.

Front, rear and footprint

IST7-100 · Front, rear and footprint
ModelW × D × H (mm)Weight
IST7-100400 × 960 × 1193165 kg

BB5 to BB8, matched to every IST7

IST7-100 · BB5 to BB8, matched to every IST7
UPSIST7-80 · 100 · 120
BB5—
BB630–36 × 60 Ah
BB730–36 × 80 / 100 Ah
BB860 / 64 × 80 / 100 Ah
2 × BB8120 / 128 × 80 / 100 Ah

Battery connection by UPS model

IST7-100 · Battery connection by UPS model
UPSIST7-100
I nom. (A)241
I max. (A)279
+/N/− mm²50
PE mm²35

Installation

Installing the IST7-100: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

IST7-100 · installation
ItemFigureSource
Clearancesfront 800 mm, rear 800 mm, left 800 mm, right 800 mm, top 800 mmAEC IST7 60–200 user manual p.35 §3.2.3
Cable entryBottom, through the baseAEC IST7 60–200 user manual
Heat at full load3.63 kW at 100 kW load, 96.5 % efficiencyAEC IST7 60–200 user manual p.87 §A; output PF 1 (EMEA 2026 catalogue)
Operating temperature−5 to 40 °C, best 20–30 °CAEC IST7 60–200 user manual p.34–35 §3.2.2
Switches and terminalsMains, bypass, output and maintenance bypass switches behind the lockable front door; terminals behind the front and rear wiring covers.AEC IST7 60–200 user manual p.13 Fig. 2-2/2-3 (handle on the left edge)
DoorOne leaf, hinged on the rightAEC IST7 60–200 user manual p.13 Fig. 2-2/2-3 (handle on the left edge)

Size and floor

How big it is

400 × 960 × 1193 mm · 165 kg.

0.38 m²footprint
430 kg/m²floor load
1.19 mheight

Floor load = weight ÷ footprint (165 kg).

1.75 mFrontSide4009601193

Efficiency

How efficient is the AEC IST7-100 at your load?

IST7-100, 100 kW at its rating, online, double conversion (typical curve, AEC's method). Heat to remove on this curve: 25%: 1.07 kW (η 95.9%) · 50%: 1.81 kW (η 96.5%) · 75%: 2.96 kW (η 96.2%) · 100%: 4.28 kW (η 95.9%). At 50% load, 24/7, it loses about 15,886 kWh a year.

96.5%50% · Typical curve, derived from the datasheet efficiency of 96.5% (AEC method)

How the curve is drawn and where each figure comes from: the IST7 60–200 range page.

Load
—
Lost as heat
—
Energy lost in a year, 24/7
—
Its cost in a year at € per kWh
—
The catalogue's examples use €0.20 per kWh.
Where each figure comes from
ModeEfficiencyKindModelsSource
Online, double conversion25%: 95.9% · 50%: 96.5% · 75%: 96.2% · 100%: 95.9%Typical curve, derived from the datasheet efficiency of 96.5% (AEC method)allAEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape)
ECO99%Datasheet figure, load not statedall

EMEA 2026 catalogue figures: Online, double conversion up to 96.5% · ECO up to 99%.

AEC IST7-120, rendered from its 3D modelDrag to turn

In 3D

Look around the IST7-100

The turntable shows the IST7-120; the full 3D view opens on the IST7-100.

Technical data

Technical data IST7-100

Only this model's values, from the EMEA 2026 catalogue table.

IST7-100 · Technical data
General
Rated power (kVA / kW)100
Capacity upgradeto 120
Input
Connection3 phases + N + PE
Rated voltage220 / 230 / 240 V phase (380 / 400 / 415 V line)
Voltage range187–280 V phase at full power · 80–186 V with linear derating
Frequency · power factor · THDi40–70 Hz · ≥ 0.99 · ≤ 3% at full load
Bypass synchronisation range50 / 60 Hz ± 6 Hz
Battery
Nominal DC voltage (default)±216 V
String length28–48 × 12 V blocks, set on site · VRLA or lithium (BMS card)
Max. charge current30 A
Output
Voltage · frequency220 / 230 / 240 V phase · 50 / 60 Hz (± 0.1 Hz on battery)
Power factor · THDv1 (settable 0.9) · ≤ 1% linear, ≤ 4% non-linear load
Transient · unbalance · phase error≤ 5% for 0–100–0% step · 100% unbalanced load · ≤ 1°
Transfer time inverter ↔ bypass< 1 ms synchronised · < 15 ms not synchronised
Inverter overload≤ 105% continuous · ≤ 110% 60 min · ≤ 125% 10 min · ≤ 150% 1 min (IST7-120: > 125% immediate)
Bypass overload≤ 130% continuous · ≤ 150% 5 min · ≤ 200% 1 s · ≤ 300% 100 ms
System
Efficiency AC/ACup to 96.5% double conversion · 99% ECO mode
ParallelUp to 8 units, capacity or N+X · BSC dual-bus synchronisation
CommunicationRS485 · Modbus RTU · RS232 · 4 IN / 3 OUT dry contacts · EPO · SNMP slot · expansion slot
DisplayColour touch screen, 5 status LEDs, ambient light bar, 10,000 events and 10,000 user-log entries
Environment−5 … 40 °C · 0–95% RH · IP20 · < 65 dB at 1 m · forced-air cooling
Cable entrybottom (all models)
EMCIEC 62040-2:2016 · category C3 (not for residential use without additional measures)
Dimensions W × D × H400 × 960 × 1193 mm
Weight165 kg
IST7-100 · Models
ItemIST7-100
Rated power (kVA / kW)100
Capacity upgradeto 120
Power units1
Nominal DC voltage (default)±216 V
Max. charge current30 A
W × D × H (mm)400 × 960 × 1193
Weight165 kg

Specifications are subject to change without notice.

More technical detailsordering codes

Ordering codes

Ordering codes IST7-100

Ordering codes IST7-100
CodeDescription
IST7-100100 kVA, upgradable to 120 kVA
PAR-IST7-60/200Parallel kit
IST7-[kVA]-[n]X[Ah]UPS with battery cabinet, n × 12 V [Ah] (e.g. IST7-160-64X100 = IST7-160 + BB8 with 64 × 12 V 100 Ah)

Questions

Questions about the IST7-100

How much energy does the IST7-100 lose at full load?

At 100 kW, 24/7, the catalogue gives 3.6 kW of losses and 31,800 kWh a year in double conversion at 96.5%, and 1.0 kW and 8,850 kWh in ECO mode at 99%. Room cooling comes on top; the values are indicative.

Can IST7-100 units share one battery?

Yes: the units of a parallel system can share a common battery bank, or each keep its own. Up to eight units run on one load bus with the parallel kit PAR-IST7-60/200, current sharing within 5%.

How long does a 100 kVA UPS like the IST7-100 run?

2 to 50 minutes at full load (100 kW), and 5 to 117 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 30 × 12 V 60 Ah (IST7-100-30X60): 2 minutes at 100% and 5 at 50%. For other loads and batteries use the backup-time tool.

How big is the AEC IST7-100 and how much does it weigh?

The AEC IST7-100 measures 400 × 960 × 1193 mm; weight: 165 kg (size from AEC's CAD drawing, weight from the EMEA 2026 catalogue).

What is the ordering code of the AEC IST7-100?

In the EMEA 2026 catalogue the AEC IST7-100 is listed as IST7-100; AEC gives the full code, batteries included, from the load and the backup time.

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST7-100: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.