IST9 · Three-phase UPS

IST9 20 kVA Three-phase rack UPS 20 kVA, 3U, 400 V

VRLA20 kVAonline rack UPS, 3U, 3/3 · 3/1 · 1/1

The IST9 20 kVA is a 20 kVA / 20 kW online double-conversion UPS in 3U and 18.4 kg, ordered with a power distribution box and maintenance breaker. For data rooms and telecom or finance sites of 10 to 20 kW that want everything, batteries included, in one 19-inch rack.

20 kVA / 20 kWRating
438 × 535 × 130 mm (3U)W × D × H
18.4 kgWeight

Quick answers

IST9 20 kVA: quick answers

What it is
The IST9 20 kVA is a 20 kVA / 20 kW online double-conversion UPS in 3U and 18.4 kg, ordered with a power distribution box and maintenance breaker.
Who it is for
For data rooms and telecom or finance sites of 10 to 20 kW that want everything, batteries included, in one 19-inch rack.
Supply and configuration
3W + N + PE (settable 1W + N + PE) · 220 / 230 / 240 V L-N · 380 / 400 / 415 V L-L
Size and weight
438 × 535 × 130 mm (3U) · 18.4 kg
Ordering code
IST9-20 · IST9-20-[n]X9

IST9

What sets apart the IST9 20 kVA

The 20 kVA doubles the power of the 10 kVA in the same 438 × 535 × 130 mm chassis. It is the IST9 with a full ordering code in the catalogue: IST9-20 with distribution box and maintenance breaker, and IST9-20-[n]X9 with 2, 4, 6, 8 or 10 BBJ2 rack battery cabinets, that is 32 to 160 batteries of 12 V 9 Ah, all in the rack.

The catalogue's operating-cost example uses a 20 kW load: 0.83 kW of losses and 7,300 kWh a year in double conversion at 96%, 0.20 kW and 1,770 kWh in ECO mode at 99%. It still works 1/1, with 105 A at the input on a 150 A 1P breaker.

  • Against the IST9 15 kVA (one size down): Rated power 20 kVA / 20 kW against 15 kVA / 15 kW; Rated power 10 kVA / 10 kW against not published.
  • Against the IST9 30 kVA (one size up): Rated power 20 kVA / 20 kW against 30 kVA / 30 kW; Configuration 3/3 · 3/1 · 1/1 against 3/3 · 3/1; Connection 3W + N + PE (settable 1W + N + PE) against 3W + N + PE; Charging current 1–10 A (default 4 A) against 1–20 A (default 15 A); Noise (20–25 °C) ≤ 50 dB half load · ≤ 55 dB 75% and full load against ≤ 55 dB half load · ≤ 58 dB 75% · ≤ 60 dB full load.

Planning data

IST9 20 kVA: currents, breakers, cables, batteries

The rows and columns of the EMEA 2026 catalogue's and AEC manuals' tables that concern the IST9 20 kVA.

Connected, and ready for redundancy

IST9 20 kVA · Connected, and ready for redundancy
ModelModeAC input (A)Bypass input (A)DC input (A)AC output (A)
20 kVA3/363 × 3P50 × 3P100 × 3P50 × 3P
20 kVA3/163 × 3P125 × 1P100 × 3P125 × 1P
20 kVA1/1150 × 1P125 × 1P100 × 3P125 × 1P

Currents, codes and options

IST9 20 kVA · Currents, codes and options
ModelModeAC input (A)Bypass input (A)DC input (A)AC output (A)
20 kVA3/335—5630
20 kVA3/135915691
20 kVA1/1105915691

Installation

Installing the IST9 20 kVA: space, heat, cables

Each figure with its source. Heat is the power lost at the peak efficiency stated.

IST9 20 kVA · installation
ItemFigureSource
Cable entryAt the rearEMEA 2026 catalogue p.64
Heat at full load0.83 kW at 20 kW load, 96 % efficiencyEMEA 2026 catalogue p.64; output PF 1 (EMEA 2026 catalogue)
Operating temperature−5 to 40 °CEMEA 2026 catalogue p.64

Size and floor

How big it is

438 × 535 × 130 mm · 18.4 kg.

0.23 m²footprint
79 kg/m²floor load
0.13 mheight

Floor load = weight ÷ footprint (18.4 kg).

1.75 mFrontSide438535130

Efficiency

How efficient is the AEC IST9 20 kVA at your load?

IST9 20 kVA, 20 kW at its rating, double conversion, high-voltage mode (typical curve, AEC's method). Heat to remove on this curve: 25%: 0.24 kW (η 95.4%) · 50%: 0.42 kW (η 96%) · 75%: 0.67 kW (η 95.7%) · 100%: 0.96 kW (η 95.4%). At 50% load, 24/7, it loses about 3,650 kWh a year.

96%50% · Typical curve, derived from the datasheet efficiency of 96% (AEC method)

How the curve is drawn and where each figure comes from: the IST9 range page.

Load
—
Lost as heat
—
Energy lost in a year, 24/7
—
Its cost in a year at € per kWh
—
The catalogue's examples use €0.20 per kWh.
Where each figure comes from
ModeEfficiencyKindModelsSource
Double conversion, high-voltage mode25%: 95.4% · 50%: 96% · 75%: 95.7% · 100%: 95.4%Typical curve, derived from the datasheet efficiency of 96% (AEC method)allAEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape)
Double conversion, low-voltage mode25%: 93.4% · 50%: 94% · 75%: 93.7% · 100%: 93.4%Typical curve, derived from the datasheet efficiency of 94% (AEC method)IST9 20 kVA · IST9 10 kVA · IST9 40 kVAAEC datasheet: AC/AC efficiency of the IST6-PM100 100 kW power module (the curve's shape)
ECO99%Datasheet figure, load not statedall

EMEA 2026 catalogue figures: Double conversion, high-voltage mode up to 96% · Double conversion, low-voltage mode up to 94% · ECO up to 99%.

AEC IST9 20 kVA, rendered from its 3D modelDrag to turn

In 3D

Look around the IST9 20 kVA

Technical data

Technical data IST9 20 kVA

Only this model's values, from the EMEA 2026 catalogue table.

IST9 20 kVA · Technical data
General
Rated power (kVA / kW, high-voltage mode)20 / 20
Rated power (kVA / kW, low-voltage mode)10 / 10
Configuration3/3 · 3/1 · 1/1
Input
Connection3W + N + PE (settable 1W + N + PE)
Voltage range (phase)high-voltage mode 176–280 V full load, 80–176 V linear derating · low-voltage mode 90–155 V full load, 70–90 V derating
Frequency · power factor · THDi40–70 Hz · ≥ 0.99 · ≤ 3% resistive, ≤ 5% non-linear full load
Bypass50 / 60 Hz ± 10% · voltage ± 20%
Battery
Voltagehigh-voltage mode ± 96 … ± 240 V DC (± 48 … ± 120 cells of 2 V, default ± 96) · low-voltage mode ± 96 … ± 120 V (± 48 … ± 60 cells, default ± 60)
Charging current1–10 A (default 4 A)
Output
Voltage220 / 230 / 240 V L-N, 380 / 400 / 415 V L-L (low-voltage mode 110 / 115 / 120 V); 3W + N + PE, settable 1W + N + PE
Frequencytracks the bypass; 50 ± 0.1 or 60 ± 0.1 Hz in battery mode
Waveform · distortion · power factorsine wave · ≤ 2% resistive full load · 1.0
Transfer inverter ↔ bypass< 1 ms synchronised · < 10 ms not synchronised
Inverter overload≤ 105% continuous · 105–110% 60 min · 110–130% 10 min · 130–155% 1 min · > 155% 200 ms · > 200% immediate
Bypass overload< 130% continuous · 130–155% 1 min · > 155% 200 ms
System
Efficiencyup to 96% (high-voltage mode) · 94% (low-voltage mode) · 99% ECO
Display · cold starttouch screen · battery cold start fitted
CommunicationRS232 · options: SNMP, RS485 + dry contact, protocol card for the approved lithium system, parallel card
Noise (20–25 °C)≤ 50 dB half load · ≤ 55 dB 75% and full load
Environment−5 … 40 °C · 0–95% RH non-condensing · ≤ 2000 m
Dimensions (W × D × H)438 × 535 × 130 mm (3U)
Weight18.4 kg
IST9 20 kVA · Models
ItemIST9 20 kVA
kVA / kW (high-voltage mode)20 / 20
kVA / kW (low-voltage mode)10 / 10
Configuration3/3 · 3/1 · 1/1
W × D × H (mm)438 × 535 × 130
Weight18.4 kg

— not stated in the user manual. Specifications are subject to change without notice.

More technical detailsordering codes

Ordering codes

Ordering codes IST9 20 kVA

Ordering codes IST9 20 kVA
CodeDescription
IST9-20IST9 20 kVA, 1:1 · 3:1 · 3:3, external batteries, with power distribution box and maintenance breaker
IST9-20-[n]X9As above with 2, 4, 6, 8 or 10 BBJ2 rack battery cabinets: n = 32, 64, 96, 128 or 160 × 12 V 9 Ah
PAR-IST9Parallel board
DRYCNT-IST3/9 · SNMPDry-contact relay board · internal SNMP board
BBJ2Rack battery cabinet, max. 16 × 12 V 9 Ah, 3U

Questions

Questions about the IST9 20 kVA

How many batteries can the IST9 20 kVA have?

With BBJ2 rack cabinets (3U, up to 16 × 12 V 9 Ah each): 32, 64, 96, 128 or 160 batteries with 2 to 10 cabinets (codes IST9-20-[n]X9). The battery box always goes below the UPS, with a DC battery switch between battery and UPS.

What does the IST9 20 kVA deliver in low-voltage mode?

10 kVA / 10 kW: in low-voltage mode (110 / 115 / 120 V phase) the catalogue halves the 20 kVA's rating. In high-voltage mode (220 / 230 / 240 V phase) it gives the full 20 kVA / 20 kW.

How long does a 20 kVA UPS like the IST9 20 kVA run?

2 to 24 minutes at full load (20 kW), and 5 to 56 minutes at half load, with the AEC battery options in the table: the battery chosen sets the figure. With 32 × 12 V 9 Ah · 2 × 16 (IST9-20-32X9): 2 minutes at 100% and 5 at 50%. For other loads and batteries use the backup-time tool.

How big is the AEC IST9 20 kVA and how much does it weigh?

The AEC IST9 20 kVA measures 438 × 535 × 130 mm (3U); weight: 18.4 kg (EMEA 2026 catalogue).

What is the ordering code of the AEC IST9 20 kVA?

In the EMEA 2026 catalogue the AEC IST9 20 kVA is listed as IST9-20, IST9-20-[n]X9; AEC gives the full code, batteries included, from the load and the backup time.

Talk to an AEC engineer

Tell us the load, the supply and the backup time you need for the AEC IST9 20 kVA: we answer with the model and the batteries that fit. AEC International sells through distributors in about 80 countries and an agency in every Italian region: ask AEC which one serves your area.