Questions and answers
IST7 60–200: questions and answers
22 questions about the AEC IST7 60–200, from its range page and its 6 model pages, grouped by subject. Each answer is the one printed on its page; follow the link for the full data, the tables and the drawings.
No question matches. Try another word, or ask AEC.
Choosing, sizing and ordering 6 questions
Can an IST7 60–200 kVA be upgraded later?
Yes, selected models: the IST7-80 is upgraded to 100 or 120 kVA, the IST7-100 to 120 kVA and the IST7-160 to 200 kVA, by setting the capacity from the display. Hardware and footprint stay the same.
Answered on IST7 60–200
How many IST7 units can run in parallel?
Up to 8 units, for capacity or N+X redundancy, reaching 1.6 MW with 8 × IST7-200. BSC synchronisation supports dual-bus architectures, current sharing between units is within 5%, and the units can share a common battery bank.
Answered on IST7 60–200
How much energy does the IST7-100 lose at full load?
At 100 kW, 24/7, the catalogue gives 3.6 kW of losses and 31,800 kWh a year in double conversion at 96.5%, and 1.0 kW and 8,850 kWh in ECO mode at 99%. Room cooling comes on top; the values are indicative.
Answered on IST7-100
IST7 60–200: what is the ordering code of each model?
As the EMEA 2026 catalogue lists them:
| Model | Catalogue code |
|---|---|
| IST7-60 | IST7-60 |
| IST7-80 | IST7-80 |
| IST7-100 | IST7-100 |
| IST7-120 | IST7-120 |
| IST7-160 | IST7-160 |
| IST7-200 | IST7-200 |
AEC gives the full code, batteries included, from the load and the backup time.
Each model's own page, linked in the table, gives its full answer and data.
How many IST7-200 can run in parallel?
Up to eight, for 1.6 MW, with parallel cables in a ring (N units, N cables) and addresses 1–8 set from the display. A parameter match page shows any setting that differs between units and copies it to all.
Answered on IST7-200
How is the IST7-80 upgraded to 100 or 120 kVA?
The rated capacity is set from the display at engineering level, on the same hardware: no new power unit and no new cabinet. AEC service configures the upgrade.
Answered on IST7-80
Backup time and batteries 8 questions
Which batteries does the IST7 60–200 kVA use?
A string of 28–48 × 12 V blocks set on site, VRLA or lithium with the BMS card: default ±192 V (32 blocks) on IST7-60/80 and ±216 V (36 blocks) on IST7-100…200. The maximum charge current is 30 A on 60–120 kVA and 60 A on 160–200 kVA, and AEC BB5 to BB8 cabinets are ordered with the UPS in one code.
Answered on IST7 60–200
Can IST7-100 units share one battery?
Yes: the units of a parallel system can share a common battery bank, or each keep its own. Up to eight units run on one load bus with the parallel kit PAR-IST7-60/200, current sharing within 5%.
Answered on IST7-100
IST7 60–200: how long does each model run on battery?
Model by model, with the AEC battery options in each model's table (the battery chosen sets the figure):
| Model | Full load | Backup at full load | At half load | For example | Its backup |
|---|---|---|---|---|---|
| IST7-60 | 60 kW | 2 to 98 minutes | 8 to 239 minutes | 30 × 12 V 40 Ah (IST7-60-30X40) | 2 min at 100%, 8 at 50% |
| IST7-80 | 80 kW | 2 to 60 minutes | 8 to 167 minutes | 30 × 12 V 60 Ah (IST7-80-30X60) | 2 min at 100%, 8 at 50% |
| IST7-100 | 100 kW | 2 to 50 minutes | 5 to 117 minutes | 30 × 12 V 60 Ah (IST7-100-30X60) | 2 min at 100%, 5 at 50% |
| IST7-120 | 120 kW | 1 to 39 minutes | 4 to 98 minutes | 30 × 12 V 60 Ah (IST7-120-30X60) | 1 min at 100%, 4 at 50% |
| IST7-160 | 160 kW | 2 to 26 minutes | 5 to 60 minutes | 30 × 12 V 80 Ah (IST7-160-30X80) | 2 min at 100%, 5 at 50% |
| IST7-200 | 200 kW | 3 to 19 minutes | 8 to 50 minutes | 60 × 12 V 80 Ah · 2 × 30 (IST7-200-60X80) | 4 min at 100%, 10 at 50% |
For other loads and batteries use the backup-time tool.
Each model's own page, linked in the table, gives its full answer and data.
How heavy is an IST7-160 with its batteries?
The catalogue example IST7-160-64X100 weighs 294 kg for the UPS plus 2,215 kg for a BB8 with 64 × 12 V 100 Ah. A BB8 so loaded puts about 1,978 kg/m² on the floor: check the slab.
Answered on IST7-160
Which battery cabinets suit the IST7-160?
BB7 with 30–36 × 80 / 100 Ah, BB8 with 60 / 64 × 80 / 100 Ah, or two BB8 with 120 / 128 × 80 / 100 Ah. BB5 and BB6 are not listed for it.
Answered on IST7-160
Which batteries suit the IST7-200?
The catalogue lists BB8 with 60 / 64 × 80 / 100 Ah or two BB8 with 120 / 128 × 80 / 100 Ah, the string split at the neutral (+, N, −). Lithium cabinets are available on request with the BMS card.
Answered on IST7-200
Which battery cabinets suit the IST7-60?
BB5 with 30–38 × 40 Ah, BB6 with 30–36 × 60 Ah, BB7 with 30–36 × 80 / 100 Ah, BB8 with 60 / 64 × 80 / 100 Ah and two BB8 with 120 / 128 × 80 / 100 Ah. Lithium cabinets are available on request.
Answered on IST7-60
Which battery cabinets go with the IST7-80?
From BB6 (30–36 × 60 Ah) upwards: BB7 with 30–36 × 80 / 100 Ah, BB8 with 60 / 64 × 80 / 100 Ah, or two BB8. The BB5 is not listed for the 80–120 kVA.
Answered on IST7-80
Installation, size and connections 3 questions
What are the dimensions, weights and clearances?
The 60–120 kVA cabinet measures 400 × 960 × 1193 mm (153–167 kg) with bottom cable entry; the 160–200 kVA cabinet 600 × 1000 × 1600 mm (294–296 kg) with top cable entry. Leave at least 800 mm at the front, rear and above: cooling air enters at the front and leaves at the rear.
Answered on IST7 60–200
IST7 60–200: how big is each model and how much does it weigh?
Width × depth × height and weight, model by model:
| Model | Size | Weight |
|---|---|---|
| IST7-60 | 400 × 960 × 1193 mm | 153 kg |
| IST7-80 | 400 × 960 × 1193 mm | 163 kg |
| IST7-100 | 400 × 960 × 1193 mm | 165 kg |
| IST7-120 | 400 × 960 × 1193 mm | 167 kg |
| IST7-160 | 600 × 1000 × 1600 mm | 294 kg |
| IST7-200 | 600 × 1000 × 1600 mm | 296 kg |
Size from AEC's CAD drawing, weight from the EMEA 2026 catalogue.
Each model's own page, linked in the table, gives its full answer and data.
How much space does the IST7-60 need?
The cabinet is 400 mm wide and 960 mm deep, with at least 800 mm free at the front, rear and above: air enters at the front and leaves at the rear. Cables come in from below; the unit is positioned on castors and then anchored to the floor.
Answered on IST7-60
Communication and monitoring 2 questions
Which communication interfaces does it have?
RS485, Modbus RTU, RS232, EPO, USB and 4 dry-contact inputs / 3 outputs with assignable functions are standard. Options include an SNMP card with a temperature and humidity sensor port, dry-contact expansion (+3 inputs, +2 outputs) and a BMS card for lithium batteries.
Answered on IST7 60–200
IST7-120 or an upgraded IST7-80 / IST7-100?
All three end at 120 kVA in the same cabinet. Buy the IST7-120 when the load is already there; buy the IST7-80 or IST7-100 when it will grow, and raise the capacity from the display later.
Answered on IST7-120
Efficiency and operation 2 questions
How efficient is the IST7 60–200 kVA?
Peak AC/AC efficiency is 96.5% in online double conversion and 99% in ECO mode, with output power factor 1 (kVA = kW). At a 100 kW load, AEC's indicative calculation gives 3.6 kW of losses (≈ € 6,350 per year) in double conversion against 1.0 kW (≈ € 1,770) in ECO.
Answered on IST7 60–200
What overload does the IST7-120 accept?
On the inverter: 105% continuous, 110% for 60 minutes, 125% for 10 minutes, then immediate protection above 125%. The static bypass carries 130% continuous, 150% for 5 minutes, 200% for 1 s and 300% for 100 ms.
Answered on IST7-120
Warranty, service and maintenance 1 question
What warranty and service come with the IST7 60–200 kVA?
A 3-year warranty, extendable with a maintenance contract, and 24/7 technical assistance by phone and WhatsApp. The UPS stores up to 10,000 events and wave captures that are exported to USB for the service report.
Answered on IST7 60–200
By range
Still a question?
Tell us the load, the supply and the backup time you need: AEC answers with the model and the batteries.